ML19345C902

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 80-41, Failure of Swing Check Valve in Decay Heat Removal Sys at Davis Besse Unit 1. No Response Required
ML19345C902
Person / Time
Site: South Texas  
Issue date: 11/10/1980
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Opera G
HOUSTON LIGHTING & POWER CO.
References
NUDOCS 8012080580
Download: ML19345C902 (1)


Text

._

a.

hs/

/

,cf'" "D,

f UNITED STATES

~2 + ',,, ;

NUCLEAR REGULATORY COMMISSION q

>ci s

E REGION V

%,,,',[#

k

$11 RYAN Pt.AZA D6tVE. SUITE 1000 ARuNcToN. texas 7eo11 November 10, 1980 In Reply Refer To:

f RIV Z

Occket Nos. 50-498/IE Infomation Notice No. 80-41 Q

50-499/IE Infomation Notice No. 80-41

~

g '. ~

  • id q >

7 J

i;

.g

~

Houston Lighting & Power Company N

.7

' 'il d

ATTK: Mr. G. W. Oprea, Jr.

g; Executive Vice President Post Office Box 1700 Houston, Texas 77001 Gentlemen:

This IE Information Notice is provided as an early notification of a possibly significant matter. It is expected that recipients will review the information for possible applicability to their facilities. No specific action or response is requested at this time. If further NRC evaluations so indicate, an IE Circular or Sulletin will be~ issued to recomend or request specific licensee actions.

If you have questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Sincerely, i

ad(_A!

2^ jY m

Karl V'. Seyfri Director

Enclosures:

1.

IE' Infomation Notice No. 80-41 2.

List of Recently Issued IE Infomation Notices 8 012 080 f80

i SSINS No.:

6835.

Accession No.:

8008220260 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT y

WASHINGTON, D.C.

20555 IE Information Notice No. 80-41 Date:

November 10, 1980 Page 1 of 1 FAILURE OF SWING CHECX VALVE IN THE DECAY HEAT REMOVAL SYSTEM AT DAVIS-BESSE UNIT NO.1 Descriotion of Circumstances:

On October 9, 1980 the Resident Reactor Inspector at the Davis-Besse facility was informed that the licensee had perfortned leak rate tests and identified exces-sive leakage through Decay Heat Removal System check valve CF-30.

Valve CF-30 is the inboard one of two in-series check valves that is used to isolate the reactor coolant system from the low pressure decay heat removal system. On further investigation the licensee found that the valve disc and arm had separated from the valve body and was lodged just under the valve cover plate.

The two 2. 5/8 x 5/8-inch bolts and locking mechanism for the bolts that holds the arm to the valve oody were missing and have not been located.

The CF-30 valve is. a 14-inch swing check valve manufactured by.Velan Valve Corporation.--

The cause of the failure has not been identified.

The test that was in progress when the failure was identified was being con-ducted in response to a letter from Darrell G. Eisenhut, Office of Nuclear Reactor Regulations to all Light Water Reactor Licensees, LWR Primarv CooTant ystem Pressure Isolation Valves, February 23, 1980.

This IE Information Notice is provided as an early notification of a possibly significant matter that is still under review by the NRC staff.

It is expected that recipients will review the information for possible applicability to their facilities. No specific action or response is requested at this time.

If NRC evaluations so indicate, further licensee actions may be requested or required.

No written response to this IE Information Notice is required..If you have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

l J

J

IE Information Notice No. 80-41 November 10, 1980 LISTING OF RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued To Notice No.

Issued 80-34 Baron Dilution of Reactor 9/25/80 All Pressurized Coolant During Steam Water Reactor Generator Cecontamination Facilities holding power reactor Operating Licenses (OLs) 80-35 Leaking and Dislodged 10/10/80 All categories G and Iodine-124 Implant Seeds G1 medical licensees 80-36 Failure of Steam 10/10/80 All nuclear power Generator Support Bolting reactor facilities holding Operating Licensees (OLs) or Construction Permits (cps) 80-37 Contaimeent Cooler Leaks 10/24/80 All nuclear power and Reactor Cavity facilities holding Flooding at Indian Point power reactor Operating.

Unit 2 Licenses (OLs) or Construction Permits (cps) 80-38 Cracking in Charging 16/30/80 All Pressurized Water Pump Casing Cladding Reactor Facilities holding power reactor Operating Licenses (OLs) and Construction Permits (cps) 80-39 Malfunctions Of Solenoid 10/31/80 All light water reactor Valves Manufactured By facilities holding Valcor Engineering Corporation power reactor Operating Licenses (OLs) or Construc-tion Permits (cps) 80-40 Excessive Nitrogen 11///80 All power facilities Supply Pressure with an Operating License Actuates Safety-Relief (OL) or Const*"ction Valve Operation to Permit (CP)