ML19345C822

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 80-41, Failure of Swing Check Valve in Decay Heat Removal Sys at Davis Besse Unit 1. No Response Required
ML19345C822
Person / Time
Site: Shoreham File:Long Island Lighting Company icon.png
Issue date: 11/10/1980
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Pollock M
LONG ISLAND LIGHTING CO.
References
NUDOCS 8012080446
Download: ML19345C822 (1)


Text

.

.........~..

'4 % 1 '~' ' ^

8888g' 9

9 o

UNITED STATES l'

~,j NUCLEAR REGULATORY COMMISSION j

REGION 1 0,

631 PARK AVENUE

,#g KING oF PRUSSIA, PENNSYLVANIA 194os November 10, 1980 e,

Docket No. 50-322

}.~y Long Island Lighting Company T.

ATTN:

Mr. M. S. Pollock Vice President - Nuclear

[

1E 175 East Old Country Road

-3 e

Hicksville, New York 11801 R

ri

]

z s

Gentlemen:

The enclosed IE Information Notice No. 80-41, " Failure of Swing Check Valve in the Decay Heat Removal System at Davis-Besse Unit No.1, is forwarded to you for information.

No written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, w'

B,oyce H. Grier Director

Enclosures:

1.

IE Information Notice No. 80-41 2.

List of Recently Issued IE Information Notices CONTACT:

E. G. Greenman-(215-337-5267) cc w/encls:

J. P. Novarro, Project Manager Edward M. Barrett, Esquire Edward J. Walsh, Esquire T. F. Gerecke, Manager, Engineering QA Department l

80120sof9(o

/

Q

\\

SSINS No.:

6835 4

Accession No.-

8008220260 UNITED STATES IN 80-41' NUCLEAR REGULATORY COMMISSION j

OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555

,o 1

l November 10, 1980 IE Information Notice No. 80-41:

FAILURE OF SWING CHECK VALVE IN THE DECAY HEAT REMOVAL SYSTEM AT DAVIS-BESSE UNIT NO. 1 Description of Circumstances:

On October 9,1980 the resident inspector at the Davis-Besse facility was informed that the ifcensee had performed leak rate tests and identified exces-sive leakage through Decay Heat Removal System check valve CF-30.

Valve CF-30 is the inboard one of two in-series check valve" that is used. to isolate the reactor coolant system from the low pressure or heat removal system.

On further investigation the licensee found the

.ne valve disc and arm had separated from the valve body and was lodgeu just under the valve cover plate.

The two 2 5/8 x 5/8 inch bolts and locking mechanism for the bolts that holds the arm to the valve body were missing and have not been located. The CF-30 valve is a 14-inch swing check valve manufactured by Velan Valve Corporation.

The cause of the failure has not been identified.

. The test that was in progress when the failure was identified was being con--

ducted in response to a letter from-Darr:11'.G. Eisenhut, Office of Nuclear -

Reactor Regulations to all Light Water Reactor Licensees, LWR Primary Coolant System Pressure Isolation Valves, February 23, 1980.

This IE Information Notice is provided as an early notification of a possibly significant matter that is still under review by the NRC staff.

It is expected that recipients will review the informatf or. for possible appif cability to their facilities.

No specific action or response is requested at this time.

If NRC evaluations so indicate, further ifcensee actions may be requested or required.

No' written response to this IE Information Notice is required.

If you have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

1

)

i L

m

IE Information Notice No. 80-41 November 10, 1980 RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued to Notice No.

Issued 80-40 Excessive Nitrogen 11/6/80 All holders of Supply Pressure a power reactor OL Activates Safety-Relief or CP Valve Operation to Cause Reactor Depressurization 80-38 Cracking in Charging 10/30/80 All holders of Pump Casing Cladding a PWR power reactor OL or CP 80-37 Containment Cooler 10/24/80 All holders of a Leaks and Reactor power reactor OL Cavity Flooding at or CP Indian Point Unit 2 80-36 Failure of Steam 10/10/80 All holders of a Generator Support power reactor Bolting OL or CP 80-35 Leaking and Dislodged 10/10/80 All holders of a Iodine-125 Implant Category G or G1 Seeds Medical License 80-34 Boron Oilution of 9/26/80 All holders of a Reactor Coolant During PWR Power Reactor OL Steam Generator Decontamination 80-33 Determination of 9/15/80 All holders of Teletherapy Timer a teletherapy Accuracy license 80-32 Clarification of 9/12/80 All holders of Certain Requirenents an NRC or Agreement for Exclusive-use State License Shipments of Radioactive Materials 80-31 Maloperation of Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor K-6005 and K-Don 6005 OL or CP Circuit Breakers

\\