Forwards Request for Addl Info from Licensee,Based Upon Review of Facility Inservice Testing Program.Requests Meeting W/Util on 800923-24
ML19345A006
Person / Time
Site: Oyster Creek
Issue date: 08/20/1980
From: Bosnak R
Office of Nuclear Reactor Regulation
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
NUDOCS 8009150506
Download: ML19345A006 (12)


Text

.

\\-

L

%c i?dM, J

Ifhg '60e B

DISTRIBUTION Ud5M Docket File (50-219)

AUG 2 0 $80 de NRC PDR MEB Reading NRR Reading 1

MEMORANDUM FOR: Dennis M. Crutchfield, Chief Operating Reactors Branch #5, Dt.

FRON:

Robert J. Bosnak, Chief Mechanical Engineering Branch,' DE.

l

SUBJECT:

OYSTER CREEK INSERVICE TESTING PROGRAM i

Plant Name: Oyster Creek Nuclear Power Plant Docket No.: 50-219 Responsible Branch a Project Manager: ORBfS, W. A. Pualson Review Branches Involved: Mechanical Engineering Branch Description of Task: Review and Evaluate Oyster Creek Inservice Testing Program Review Status: Requesting Additional Information The Mechanical Engineering Branch, Division of Engineering, has reviewed the Oyster Ernak Inservice Testing Program. Additional information in response to the attached questions is essential to the completion of our review. Please request the-licensee to have the information available for a meeting. From past experience we have found it necessary to arrange a meeting with the licensee at the plant to review in detail their response and to seek answers to additional questions thac inevitably develop from our evaluatica of their responsas. To expedite our review, we request a meetingwith 0ystar Creek on Septador 23 and 24, lg80, at the Oyster Creek Plant.

1 Robeft J.Bosnak, Chief 9

. Mechanical Engineering Branch

..- u,, Division of Engineering 4....-

s. _..;.

t.L

. O_.n ~~' ? W.w.,

Enclosere:- W Q. t'%iMS.M,[JiBIGM.?r 2 -

..; ~

As stated p g i;he w w :. a r

. - y e a.m.:e cc w/ enc 1: -

D. J M@dEM '

F 1

R. Vollmer F. Cherry n

a.-

l J. Knight R. 1, yon, EG86 W. A. Paulson W. Refits, IE, Region ~I -

T. ~

^

G. Johnson

~^

V. Nerses D**

(ontact:

Y. Norses, DE:MEB 80091 50 h[

X27468

. E:MEB M..# U.D d ' N.. 6. 4 OFFICE h.'.DE:MEB D.

.q' d.

.......i..

suRNauE)..U.VW.d h...@g.y.k..',i.... :......

4 O,re > 8!.1/80..

8!.=!80

... Th.%..

N*C FORM 318 (9 76) NRCM 0240 DU.S. GOVERNMENT PRINTING OFFICE: 1979-289 369 3.-

.2_..___..._--...-~~.-----

7._.

.-- o i

J i

i' i

- i r

L QUESTIONS AND ComENTS CONCERNING 2

THE JERSEY CENTRAL POWER AND LIGHT COMPANY COMPANY IN-SERVICE TESTING PROGRAM l

FOR OYSTER CREEK (Ref: Docket Number 50-219) 1 4

7 4

l 4

1 N

e O

9 5

= 9 4

I I

i 4

~
  • 6.. e

.s

,.m..

f,-...m....,.,...._

OYSTER CREEK NUCLEAR STATION Pump Testing Program

?

1.

How is flow rate measured for the poison pumps?

2.

Mcw are the mechanical characteristics of the poisen pumps determined and assured during the performance testing since neither vibration or bearing temperatures are measured?

3.

Provich the specific technical information that justifies pump testing intervals greater than that specified by Section XI.

4.

Provide the specific technical information that supports the determination that vibration is a singularly reliable indication of pump mechanical condition and bearing temperature measurements are not required.

5.

How is flow rate measured for the service water and emergency service water punps? How are vibration measurements taken on these pumps?

6.

How is flow rate measured for the fire protection pumps? How are vibration measurements taken on these pumps?

7.

How is ficw rate measured for the condensate transfer pumps?

8.

How is flow rate measured for the Reactor Building closed tooling water pumps?

9.

How are differential pressure and flow rate measured for the Fuel Pool Cooling pumps?

10.

Is lubricant level or pressure measured or observed for all pumps listed in the IST Program as required by Section XI?

11. Review the safety related function of the diesel fuel oil transfer

, pumps to determine.if they should be included in the IST program. '

12. What supplies cooling water to the Emergency Diesel Generators?

~

13. Are the Reactor Shutdown Cooling pumps ever utilized to mitigate the consequences of an accident or safely shutdown the plant?

Valve Testing Program A.

Isolation Condenser 1.

Review the safety related function of valves V-14-30, 31,' 32, 33, 34, 35, 36 & 37 to determine if they should be categorized A.

2.

Specific relief must be requested from exercising category 8 passive valves V-14-2 and V-14-6.

B.

Reactor Shutdown Cooling 1.

Review the safety function of all valves listed in this system to determine if they should be categorized A.

I 2.

Provide the P&ID that.,shows the major components and piping of the Reactor Shutdown cooling system for our review at the working l

meeting.

C.

Poison System-1.

How are check valves V-19-37 and V-19-38 full stroke exercised quarterly?

2.

Specific relief must be requested from exercising category B passive valves V-19-35 and V-19-36.

3.

Review the safety related functions of check valves V-19-20 and V-19-16 to determine if they should be categorized A/C.

Provide the specific technical-information why these valves cannot be exercised during power operation or cold snutdowns!

4 Review the safety related function of the following valves to determine if they should be included in the IST program ano categorized E.

V-19-29 (0-10)

V-19-22 (J-8)

V-19-15 (D-3)

V-19-14 (F~-3 )

V-19-17 (F-2)

V-19-18 (F -2 )

D.

Containment Spray 1.

How are check valves V-21-10, 8, 4 & 2 full stroke exercised?

2.

Review the safety related function of the following valves to determine if they should be categorized A.

V-21-11 V-21-17 V-21-18 V-21-5 Y-21-13 V-21-15 3.

What is the safety related position of check valves V-21-20 &

197 Should these valves be categorized A/C?

~

,w-

4.

Review the safety related function of thi following valves to determine if they should be included in the IST program and categorized as. indicated.

?

Category A Loca tion V-21-1

( E-9 )

V-21-3 (E-8)

V-21-7 (E-7 )

V-21-9 (E-6)

Category A/E V-21-200 (B-8)

V-6-134 (S-7)

V-6-136 (B-9)

V-6-138 (C-10)

E.

Clean-uo Demineralizer 1.

Review the safety related function of, valves V-16-1, 2, 14 & 61 to determine if they should be categorized A.

Provice the specific technical information why these valves cannot be exercised during power operation or cold shutdowns.

2.

Review the safety related function of check valve V-16-52 to determine if it should be categorized A/C.

Provide the specific technical information why the reverse flow test for this valve cannot be performed during power operation or cold shutdcwn.

3.

Review the safety related function of check valve V-16-84 to determine if it should be categorized A/C. What alternate methods have been considered for testing this valve?

1

___._ew=e-e----

l F.

Hydraulic Control Unit

. j-1.

'If valves 120, 121, 122 & 123 have no safety related functions, why are they included in the IST program?

2.

How is check valve 138 verified shyt during the control rod scram test?

3.

What is the technical specifications 4.2.A-0 frequency for the control rod scram tests?

4 How does the control rod scram test verify valve 106 exercises to its safety related position?

5.

Provide the P&ID that shows the scram discharge volume and associated piping and valves.

6.

Review the safety related function of the following valves to determine if they should be included in the IST program and categorized as indicated.

Category C Location 108

( J-4 )

Category E 101 (G-8 )

102 (F-5) 7.

What-is the safety related function of valve V-15-29?

8.

Review the safety related function of check valves V-15-27 ano V-15-28 to determine if they should be categorized A/C.

f 9

pow -~, -

-s

G.

Fuel Pool Cooling 1.

What is the safety related function of the fuel pool cooling I

sys tem?

H.

Core Soray 1.

Review the safety related function of valves V-20-32, V-20-3, V-20-33 and V-20-4 to determine if they should be categorized A.

2.

How are valves V-20-8, V-20-9, V-20-16, and V-20-22 full stroke exercised during power operation?

3.

How are check valves V-20-60 and V-20-61 full stroke exercised during power operation?

4.

How are valves V-20-10, V-20-ll, V-20-38 and V-20-39 verified open during the quarterly exercising tests?

5.

Are valves V-20-92, V-20-94, V-20-93 and V-20-95 normally open valves? Should these valves be categorized A?

6.

How are check valves V-20-52, V-20-53, V-20-54 ana V-20-55 full stroke exercised during power operation?

7.

How are check valves V-20-50 and V-20-51 full stroke exercised to their safety related positions?

8.

Review the safety related functions of valves V-20 26 and V-20-27 to determine if they should be categorized A.

9.

Review the safety related functions of valves V-20-15, V-20-40, V-20-21 and V-20-41 to determine if they should be categorizec A.

How are these valves exercised during power operation without potentially overpressurizing the adjacent icw pressure piping?

-~

10.

Revica the safety related functions of check valves NZO2-A

& D to determine if they should be categorized A/C.

, B, C 11.

Review the safety related functions of valves V-Il-ll8, V-ll-110 and V-ll-ll4 to detennine if they should be included in the IST program and categorized E.

I.

Reactor Head Cooling 1.

Review the safety related function of valves V-31-2 and V-31-5 to determine if they should be included in the IST program and categorized A and A/C respectively.

J.

Main Steam 1.

Review the safety rela:sc function of the ADS valves

, NR-108 A-E, to determine if they should be categcrized B/C.

Do these valves have a safety related function other than overpressure protection of the reactor vessel?

2.

Review the safety related function of valves V-1-106

, V-1-107, V-1-110 and V-l-lli to determine if they should be categorized A 3.

Provide the specific technical information why valve V-l-lli cannot be full stroke exercised during power operation.

4 Review the safety related function of valves V-1-7, V-1-8

, V-l~9 and V-1-10 to determine if they should be categorized A.

Provide the specific technical justification for not full stroke exercising these valves during power operation.

5.

Review the safety related function of valves V-1-178, V-1-179 V-1-180 and V-1-181 to determine if they should be included in the IST program and categorized C.

~

Y 6.

Does valve V-1-71 have any safety related functions?

K.

Feedwater 1.

Review the safety related function of check valves Y-2-71, V-2-72, V-2-73 and Y-2-74 to determine if they should be categorized A.

How are these valves reverse flow tested?

L.

Condensate Transfer 1.

What is the safety related position of valves V-15-8 and V-l'5-97 How are these valves exercised to that position?

2.

Review the safety related function 'of valves V-Il-8, V-ll-9, V-ll-10 and V-11-ll to determine if they should be included in the IST program and categorized B.

M.

Service and Emergency Water 1.

Provide more detailed technical information why valves V-3-62 and V-3-63 cannot be exercised to their safety related position quarterly.

2.

What is the safety related function of valve V-3-597 3.

Provide more detailed technical information why valves V-3-87 and V-3-88 cannot be full stroke exercised during power operation.

4.

Review the safety related function of the following valves to detennine if they should be included in the IST program and categorized B passive.

o I

~_ _-. ~._.___

.m

_ _ _ m.m.m.

m V-3-33' (E-5)

Y-3-34 (F-5)

V-3-78 (A-7)

V-3-79 (B-7) t V-3-80 (8-9)

V-3-81 (C-9)

N.

Closed Cooling Water 1.

Provide more detailed technical information why valves V-5-153 and V-5-154 cannot be full stroke exercised to their safety related position quarterly.

2.

Provide the specific 'achnical information why check valve V-5-165 cannot be exer:ised during power operation and cold shutdowns.

Should this valve be categorized A/C?

3.

Provide the specific technical information why valves V-5-147, V-5-166 and V-5-167 cannot be full stroke exercised during cold shutdowns.

Should these valves be categorized A?

4.

What is the safety related functon of valve V-5-136?

P.

Fire Protection 1.

What is the safety related function of valve V-9-2S?

2.

How are valves V-20-82, Y-20-83, V-20-88 and V-20-89 full stroke exercised without contaminating the core spray system with fire system water?

3.

Review the safety related function of the following valves to detennine if they should be included in the IST program and j

categorized B.

w

+&

~

V 4 (E-3)

/

V-9-5 (C-3) t V-9-9 (D-7)

V-9-10 (D-7) 1 Q.

Rad Was te

,f 1.

Review the safety related function of valves V-22-1, V-22-2, i

V-22-28 and V-22-29 to determine if they should be categorized A.

R.

Demineralized Water Transfer 1.

Review the safety related function of valves V-12-60 and V-12-13 to determine if they should be categorized A and A/C rispectively.

S.

Miscellaneous 1.

Provide a list of containment isolation valves for cur review at the working meeting.

s Prov de the P&ID's that show the drywgli purge and ventilation 2.

i systems.

3.

Provide the P&ID that shows the sample system.

4.

Provide the P&ID's that show the the diesel fuel transfer and starting air systems.

5.

Does Dyster Creek utilize any excess flow check valves in instrument lines penetrating the drywell?

6.

Specific relief must be requested from the exercising requirements for each passive valve indicated in the IST program.