Proposed Revision to Tech Spec Table 3.6-2, Containment Isolation Valves
ML19344B285
Person / Time
Site: Davis Besse 
Issue date: 08/22/1980
From:
TOLEDO EDISON CO.
To:
Shared Package
ML19344B283 List:
References
NUDOCS 8008260252
Download: ML19344B285 (1)


Text

f A

Dockst No. 50-346

'b Licanes No. NPF-3 Serial No. 644 TABLE 3.6-2 August 22, 1980 CONTAINMENT ISOLATION VALVES (Conti.nued)

PENETRATION VALVE ISOLATION NUMBER NUMBER FUNCTION TIME (seconcs) 67 CV5090 Hydrogen Dilution System Supply 60 6BA SS235A Pressurizer Quench Tank Sample 30 68A 55235B Pressurizer Quench Tank Sample 30 6BB CV5010B Containment Air Sample 15 68B CV5011B Containment Air Sample 15

~

69 CV5065 Hydrogen Dilution System Supply 60 71B CV5010A Con'tainment Air S' ample 15 71B," CV5011'A Containment Air Sample 15 71C CV1544 Core Floco Tank N2 Fill 10 73B CV5010C Containment Air Sample 15 738 CV5011C Containment Air Sample 15 74B CV50110 Containment Air Sample 15 74B CV5011D Containment Air Sample 15 B.

CONTAINMENT PURGE AND EXHAUST ISOLATION 33 *FCV5005 Containment Vessel Purge Inlet Line 10 33 F7PCV5006 Containment Vessel Purge Inlet Line 10 34p# CV5007 Containment Vessel Purge Outlet Line 10 34$ # CV5008 - Containment Vessel Pure.: Outlet Line 10 C.

OTHER 5 # SW1366 Containment Air Cooling Units SW Inlet Line N/A l

6 i SW136B Containment Air Cooling Units SW I

Inlet Line N/A 7 i SW1367 Containment Air Cooling Units SW Inlet Line N/A 9 i $W1356 Containment Air Cooling Units SW Outlet Line N/A Gf poC y 4-g PgovlsioNs oF c2Pc-< IF icA TlotJ 3 0 fl ARE N oT (PPL\\ cA B LE.

r DAVIS-BESSE, UNIT 1 3/4 6-19 l_