05000296/LER-1980-061-03, /03L-0:on 801230,SLC Pump Discharge Relief Valve 3B Would Not Relieve within Tech Spec.Caused by Galled Valve Disc or Disc Binding W/Valve Guide.Valve Replaced

From kanterella
(Redirected from ML19341B310)
Jump to navigation Jump to search
/03L-0:on 801230,SLC Pump Discharge Relief Valve 3B Would Not Relieve within Tech Spec.Caused by Galled Valve Disc or Disc Binding W/Valve Guide.Valve Replaced
ML19341B310
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 01/26/1981
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19341B308 List:
References
LER-80-061-03L-03, LER-80-61-3L-3, NUDOCS 8101300641
Download: ML19341B310 (2)


LER-1980-061, /03L-0:on 801230,SLC Pump Discharge Relief Valve 3B Would Not Relieve within Tech Spec.Caused by Galled Valve Disc or Disc Binding W/Valve Guide.Valve Replaced
Event date:
Report date:
2961980061R03 - NRC Website

text

.

p f nw J,de U. S. NUCLEA3 CEGULATC7.Y COMMIS$10N e

k,l LICENSEE EVP1T REPORT CONTROL BLOCK: l l

1 l

l l

ih (PLEASE PAINT OR TYPE ALL REQUIRED INFORMATION)

I 6

A l Al Ll Bl Rl Fl 31@l Ol Ol -l 01 Ol 0l 0l O l -l 0101@l 4 l 1!1 l11il@l l

l@

)

8 9 UCENSEE COCE le 19 LaCENSE Nu dGG R J5 26 LaGENSE typt JO 67 CAI us CONT 10111 Mu'R$ l L @l Ol S l 0l 010l 2l 916 Cl 11213 l Ol B I 0 @l o l 1 l 2 l 618 l 1 l@

7 8

60 61 DOCKET NUUSER 68 63 EVENT DATE 34 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBA8LE CONSECUENCES h l ITTT1 i puring refueling operations while perfoming SI 4.4.A.2 it was found that 3B l

g l SLC pump discharge relief valve would not relieve at 1425 +- 75 psig.

Reference l

go,,,l T.S. 4.4.A.2.

3A pump was demonstrated operable. There were no significant l

L O I s l I resulting events. There was no danger to health or safety of public. Previous l

,o g jl event BFRO-50-259/79002.

l i

I 10171 l I

iotsii Sv5 TEM

CAUSE

CAUSE CovP.

SALVE CCCE CODE SU8COCE COMPONENT CODE SUSCCDE SU8 CODE l0191 i Sl Fl@ W@ l B ]@ lV l A lL lV lE lX l@ Q@ Q @

i 7

8 9

10 11 12 13 18 19 20 S EQUE NTI AL OCCURRENCE REPORT REVISION EVENT YE AR R EPORT NO.

CODE TYPE NO.

@ y*ggn ROl2 s8 [0 l b l 01 61 1l y

1 0l 3l

[ LJ

[, -j l0 l u'vY 22 23 24 as 2r 2s 2s 30 3

32 Y

N AC ON ON P NT VET wCURS S B IT D FOR S.

SU L R uANUFACTURER lClg W @

l Z lg l36Zl@ l 0] 0l Cl 0l W@

W@ Q@

l C ! 7 l1 10 l@

34 35 37 40 41 42 43 44 47 33 CAUSE OESCRIPTION AND CORRECTIVE ACTIONS @

l i l o i l Suspect valve disc called or binding vitt valve cuide. Valve was reolaced and I

ii ii l l verified operable. The damaged valve. Crosby. size 1 x 2. tyre F m 1600 nRf I

y l relief valve, will be sent to nanufacturar for rebuild and testine.

No recurrence i

I g I control required.

I Wl 90 7

8 3 A US

% POWER OTHER STATUS Di RY DISCOVERY DESCRIPTION NA l

l B l@l Surveillance testing l

l1 l 5 l W@ l 0 l 0 l 0 ]@l ACTIVIT Y CO TENT RELEASED OF RELE ASE AMOUNT OF ACTIVITY LOCATION OF RELE'4E NA l

l NA l

li 16 l l zl h W@l 7

8 9 10 ft 44 45 80 PE A50NNEL F XPOSURES NUveER TYPE DESCRepflON NA l

I1I7ll0l0l0l@ W @l

  • ERSOwe't iN;u' dies NVV9 E R CESCRIPTION NA l

11 laj l0l0l0l@l 90 7

8 9 11 12 LOSS OF OR OAMAGE TO FACILITV TYPE

DESCRIPTION

NA l

uit! LZj@l 80 7

4 9 10 8,

W l N i@DESCRrPTION

'SSUE l

NA l

llllll1Iiilll*

6f 69 80 3 F

8 9 to NAME OF PREPARER PHONE:

kW

s Tennessee Valley Authority Forn 5F,17 Browns Ferry Nuclear Plant BF 15.d 1/10/79 LER SUPPLEMENTAL INFORMATION BFRO 296/ 80061 Technical Specification Involved 4.4.A.2 Reported Under Technical Specification 6.7.2.b(2)

Date of Occurrence 12/30/80 Time cf Occurrence 1000 Unit - 3 Identification and Description of Occurrence:

While performing SI 4.4.'A.2 it was found that 3B SLC pump discharge' relief valve would not relieve at 1500.plus psi.

Conditions' Prior to Occurrence: -

Unit 1 @ 27%

Unit 3 @ 100%

" Unit 3 0 0% refueling outage Action specified in the Technical Specification Surveillance Requirements met due to inoperable equipment. Describe.

None required.

Apparent Cause of Occurrence:

Valve disc galled or binding with valve guide.

Analysis of Occurrence:

There was no damage to plant equipment. There was no activity release, no personnel exposure or injury and so dagger to the health or safety of the public.

s

Corrective Action

' Valve was replaced and the new valve verified operable. The damaged valve vilj. be sent to the manufactufer for rebuild and testing.

Fauure Data: /79002, 296/74018, 296/77008, 296/77001, and 296/77013 and 296/78034 sim-50-239 and 260/78010.

  • Retention:

eriod - petime; Responsibility - Administrative Supervisor

/

  • Revision: