O i

Sheet 1 of 50 s

1 O

Metallurgical Analysis with Attachment-A, Stress Analysis of Failed Steam Generator Support Bolts from Prairie Island, Unit-1 of Northern States Power Co.

Report No. IE-121 December 8, 1980 Prepared for: United States Nuclear Regulatory Commission Office of Inspection and Enforcement st19 lie NRC Contract 05-80-251 Ms500 PAR: NRC-IE-80/81, Task 05 THO AAS L k 1

==

E PROFT I

15/29 I

0

~ ILWAUAEE 4

[

b: :

-2 Corpora tion { '

Proft,7.E.

L' Thomas L.

    1. fsgssellOU Technimet

,s ?Gogiunnsisi, h,

~

N yW WALTER J.

W i and:

Ic S'j'dY j

7 Walter J. Fofey, P.E.

g

/ y:8l 5

/'

PARAMETER, Inc.

5 t

m u n untc.

Consulting Engineers S

\\

was.

d[

Elm Grove, Wisconsin

m_w,

... ~...

a ra m ele r, n c.

u C O N $ U t Il N G GNGINtt8$

Itm G R O V4. wa$ CON $1N j

NOTICE This report was prepared as an account of work sponsored by an agency of the linited States Government.

Neither the United States Government nor any agency thereof, or any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsi-bility for any third party's use, or the results of such use, of any information, apparatus, product or process disclosed in this report, or represents that its use by such third party would not infringe privately owned rights.

l t

~.

~.

s Sh*** 3 0f 50 ar$neeler r n c.

C o N S U Lil N O E N GINII B $

Report No. IE-121 etm onove WISCONSIN TABLE OF CONTENTS Number Item

_ Description of Sheets 1.

Cover Sheet 1

2.

Notice 1

3.

Table of Contents 1

4.

Report No. 78463 Technimet Corporation 34 5.

Attachment A, Stress Analysis of Failed Steam Generator Support Bolts 13 Total 50