05000296/LER-1980-053-03, /03L-0:on 801129,refuel Platform Limit Switch Failed to Prevent Platform Movement Over Core During Functional Test.Caused by Normal Wear.Switch Replaced

From kanterella
(Redirected from ML19340D405)
Jump to navigation Jump to search
/03L-0:on 801129,refuel Platform Limit Switch Failed to Prevent Platform Movement Over Core During Functional Test.Caused by Normal Wear.Switch Replaced
ML19340D405
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 12/24/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19340D400 List:
References
LER-80-053-03L-02, LER-80-53-3L-2, NUDOCS 8012300537
Download: ML19340D405 (2)


LER-1980-053, /03L-0:on 801129,refuel Platform Limit Switch Failed to Prevent Platform Movement Over Core During Functional Test.Caused by Normal Wear.Switch Replaced
Event date:
Report date:
2961980053R03 - NRC Website

text

4 0-17 771 LICENSEE EVENT REPORT coNTRot stocic: l i

i l

l l

lh (PLE ASE PRINT OR TYPE ALL REOUIRED INFORMATIONI 1

4 l Al L l B l R l F l 3 lg 0 l 0 l-l 0 l0 l 0 l 0 l0 l-l0 l0 l@l4 l1 l1 l1 l1 lgl l

lg o i i

d 9 LICENSEE CODE 14 15 LICENst NUMetR 2$

26 LICENSE TYPE JO Si 6 A T W CON'T 3[,$ [_1_.J@l 015101010121916 l@l l 11 12191810 I@l il 212l 4l a l O l@

o i 8

60 el CoCiL ET NUM8ER 68 69 EvtNT oaf t le 75 REPORT oatt et EVENT OESCRIPTION ANO PROBABLE CONSEQUENCES h g l With unit 3 in a scheduled refueling outege, the limit switch on the refuel platform _

[TTT] l failed to prevent the platform's moving over the core during a functional test. See o 4 1 Tech. Spec.

'.10.A.1.

There was no danger to the health or safety of the public I ;o;.,j land no resulting chain of events. A similar previous occurrence is reported in

BFRO-50-260/80054.

o,,

ITTIl!

I o lH l l

' $Ee"

  1. [o'de' stie^c'$os CouromrNT Coor suoE'o's s E 'e C

g lFlDlg g g ] g lClKlTlBlKlRlg {E p g

F e

9 to 11 12 13 18 19 20 sf 0UENTI AL oCCundf 4CE HEPoRT NE W ON

,,,,fVENTYCAR REPOH T NO.

CooE TYPE No

@,ar=m n()1 81 01 l--J 1 01 5l 31 (f_j 10131

!L I L-1 loj d

u

_ 28 22 J3 74 26 2F 28

.'9 30 J1 JJ A FN A TIO oNPLANT M T MOURS S8 af u For hun su L MANLF

+e.

ICl@lzl@

Lzj@

I zlO l ol ol ol oJ W@

lYl@ 6@

1 c 10181.0 41 4;

43 44 JJ J4 JS 36 J/

.o CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h

,gol]The limit switch operator on the refuel platform failed to function, due to normal The switch was replaced and the functional test run successfully. No future
,;,j l wear.

corrective action is needed.

GE, Model CR115G307.

,,,, g m1 l i l 41 1 a,

or>.tR:Tafus @

5's5EOv" oisCoviav ocsCR*rion @

j

's'ilfs' snowtn NA l

l B l@l observed during test Ii l5 I [,lij @ l 0l Ol Ol h l 1

",i,, m r co'kT

.MoumT or 4CTivirv @ I tvarioN or asttesc @

I i 161 LIJ @o c.. ar.s.1.z_J@l l

neucc l

NA NA

.innN.lt,om&'.,is yesen,,,,0N @

ern TV, l

)

li l il 101 O l 0 l91 z l@l NA rtne,oNNE L INJU IEs N UMe t H otsCR'PtioN lilaIl0101Ol@l NA i

a

')

11 17 I (r.'i OF on DAMAGE To F ACILITY TV8f GE SCniP flON fTT l I zl@l NA r

n 1 in

)(;LP PTION FTT-I ;sutoLNJ81 NA l

ll lllll!ll !I r.; 69 i

a 9 in NAME OF PREPARER PH O*J E 8 0.12 3 o q53 7, -

o 9

I Tennessee Valley Authority Form BF-17 Browns Ferry Nuclear Plant BF 15.2 1/10/79 LER SUPPLEMENTAL INFORMATION BFRO-50 296 / 8053 Technical Specification Involved 3.10.A.1 Reported Under Technical Specification

6. 7. 2. b( 4)

Date of Occurrence 11/29/80 Time of Occurrence 1300 Unit 3

Identification and Description of Occurrence:

With unic 3 in a scheduled refueling outage, the limit switch on the refuel platform failed,to prevent the platform from moving over' the core during a functional test.

Conditions' Prior to Occorrence:

Unit 1 - in shutdown condition Unit 2 - 90% steady state power

. Unit 3 - in scheduled refue. ling outage.

Action specified in the Technical Specification Surveillance Requirements met due to inoperable equipment. Describe.

N/A Apparent Cause of Occurrence:

The limit switch failed because of natural end of life due to wear.

Analysis of Occurrence:

There was no danger to the health or safety of the public, no damage to plant or equipment, no release of activity, and no significant resulting chain of events.

Corrective Action

The switch was replaced and the functional test run successfully.

Failure Data:

I.ER BFRO-50-260/80054

  • Retention :

eriod - Lifetime; Responsibility - Administrative Supervisor

  • Revision:

uW r

..-m_ _.,

r-

, c.