,c KING oF PRUSSIA, PENNSYLVANIA 19406 ms y-October 31, 1980 2m Docket No. 50-293
-~
Boston Edison Company M/C Nuclear b":_
ATTN:
Mr. A. V. Morisi E
Nuclear Operations Support Manager 5
MC.
800 Boylston Street R
ill Boston, Massachusetts 02199 Gentlemen:
The enclosed IE Information Notice No. 80-39, " Malfunctions of Solenoid Valves Manufactured by Valcor Engineering Corporation," is forwarded to you for information.
No written response is required.
If you desire additional information regarding this matter, please contact thi; office.
Sincerely, Bo oe H. Grier Director
Enclosures:
1.
IE Information Notice No. 80-39 2.
List of Recently Issued IE Information Notices CCNTACT:
D. L. Caphton (215-337-5265) cc w/encis:
R. D. Machon, Nuclear Manager - Pilgrim Station l
8011140 $ I
SSINS N:.:
6835 Accession Nc.:
8008220245 IN 80-39 UNITED STATES NUCLEAR REG'JLATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D. C. 20555 October 31, 1980 IE INFORMATION NOTICE NO. 80-39: MALFUNCTION OF SOLENOID VALVES MANUFACTURED BY VALCOR ENGINEERING CORPORATION PURPOSE:
The intent of this Information Notice is to alert holders of construction permits and operating licenses for nuclear power-n1 ants of a potentially j
generic problem involving the malfunctioning of certain solenoid valves manu-factured by the Valcor Engineering Corporation (Valcor).
The solenoid valves i
so involved are designated as Valcor Valve Model No. V52600-554-1.
Valcor has inform.J us that these valves have only been supplied to the McGuire facility; however, since these valves were substituted for solenoid valves of another manufacturer that did not meet the requirements of IE Bulletin.No. 79-01 and its amendments, licensees and holders of construction permits should take into account the problem identified in this Information Notice prior to making any similar substitution.
BACKGROUND:
By TWX dated June 27, 1980, Valcor submitted a preliminary 10 CFR Part 21 Report addressing the malfunctioning of Valcor solenoid valves at the McGuire i
facility.
The malfunctioning valves have been identied as Valcor Valve Model No. 52600-554-1.
This TVX was subsequently followed by a letter dated July 3, 1980, transmitting a more detailed Part 21 Report entitled," Quality Assurance Report", a copy of which is attached hereto as Enclosure No. 1.
l In brief, the malfunction appears to be an intermittent type wherein the valve fails to cycle frce OPEN to CLOSE to OPEN immediately after a sustained period of operation in the energized (OPEN) mode.
Although the valves are rated for
" continuous operation", Valcor contends that the valves were not designed to meet the operating conditions requiring the immediate cycling from OPE.1 to CLOSE to OPEN after a sustained period of continuous energi:ation.
A major source of the problem, therefore, may be a misunderstanding of the term
" continuous operation".
By letter dated July 14, 1980 to Duke Power Company, Valcor transmitted its recomendations in this matter entitled, " Outline -
Suggested Modification Procedures", a copy of which is attached hereto as Enclosure No. 2.
Enclosures:
DUPLICATE DOCUMENT Entire document previously entered into system under:
ANO 0 & & 0 h h k S.
No. of pages:
b I