Responds to NRC 800812 Request for Addl Info Re Containment Leakage Testing.Discusses Feedwater Sys Check Valves,Reactor Core Isolation Cooling Pump Discharge,Isolation Check Valves in Reactor Water Cleanup Return & Core Spray to Reactor
ML19339B186
Person / Time
Site: Pilgrim
Issue date: 10/27/1980
From: Morisi A
BOSTON EDISON CO.
To: Ippolito T
Office of Nuclear Reactor Regulation
References
80-275, NUDOCS 8011060473
Download: ML19339B186 (5)


Text

A 6

e BOSTON EDI,S O N COMPANY aewsmA6 orrie:S soo movtSvow atServ So StoN. MASSACH UGETTS O219 9 A. V. M O RIBO MANAGER NUCLEAR OPERATIONE SUPPORT DEPARTMCNT

~ ::

October 27,1980 BECo. Ltr. #80-275 5!

,Q,:~.' 3 Mr. Thomas A. Ippolito, Chief Operating Reactors Branch #2 w;,,;ts Division of Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Wasnington, DC 20555 License No. DPR-35 Docket No. 50-293 Additional Information Concerning 10 CFR 50 Aco. J Ref. a) NRC letter (T. M. Novak) to BECo (G. C.

Andognini) dated August 12, 1980.

b) BECo. letter (J. E. Howard) to NRC (D. L.

Ziemann) titled " Additional 10 CFR 50 Appendix J Evaluation" dated January 27, 1976.

Dear Sir:

Your letter Ref. a) requested information relative to implementation of Appendix J (Containment Leakage Testing) at Pilgrim Station. Accordingly, responses to your specific questions are provided below.

Item 2.1 FEEDWATER SYSTEM CHECK VALVES BECo. requested an exemption to test feedwater check valves with water as a medium in lieu of air or nitrogen. This approach is acceptable provided the test is used to verify that the check valve will remain water-covered through-out the post-accident period.

Provide the following information needed to complete our review of this request:

1.

The initial volume of water in the line at the start of the accident.

2.

The acceptance criteria for the hydrostatic test (e.g., leakage rate limit, pressure decay limit, etc.).

h6/

1

/

B0n060 %

P i

=. -

CETON E!!!ON COMPANY Mr. Thomas A. Ippolito, Chief October 27,1980 Page 2

Response

Subsequent to this request for exemption, we modified the feedwater check valves with sof t seats and have since been leak testing with air. He therefore with-draw this request for exemption.

Item 2.2 ISOLATION CHECK VALVES IN THE REACTOR WATER CLEAN-UP RETURN, REACTOR CORE ISOLATION COOLING (RCIC) PUf1P DISCHARGE, HIGH PRESSURE COOLANT INJECTION (HPCI) PUMP DISCHARGE, CORE SPRAY TO REACTOR, AND P.ESIDUAL HEAT REMOVAL (RHR) VESSEL INJECTION LINES BECo.has stated that replacing these check valves with air-testable check valves was not considered justified since the purpose of these valves is to limit reverse direction flow in case of a postulated upstream pipe break until downstream motor-operated isolation valves are shut. The statement imolies that testing of these valves with water as a medium is at least possible and perhaps currently required.

Provide your proposal to verify that these valves will limit reverse direction flow for a sufficient period of time to pennit downstream isolation including:

1.

Indications available to the operator to identify a line which should be isolated by its downstream motor-operated isolation valve.

2.

The initial water volume in the line at the start of the accident.

3.

The acceptance criteria for any required test.

Response (Items 2.2.1 and 2.2.3)

Rea-tor Water Clean-up Return Check Valve (1201-81)

Indications Available Boston Edison operators would not have to take any action since this system auto-matically trips the pumps and isolates the downstream motor-operated isolation valve upon actuation of logic circuits and alarms in the Control Room (" Clean-up Lines Excess or Negative Flow") utilizing DP1S-1243 and DPIS-1244.

Acceptance Criteria Technical Specification 4.7. A.f.3 "Any one penetration or isolation valve except main steam line isolation valves 5% L to (45)".

Reactor Core Isolation Cooling (RCIC) Pump Discharge Check Valve (AO-1301-50)

The RCIC Pump Discharge line taps into the Feedwater injection piping between the inboard and the outboard Feedwater Check Valves in Loop 'A'.

Since the request for exemption has been withdrawn for the Loop ' A' Feedwater Check Valves (Penetration 9A) (See Response to Item 2.1), the RCIC Pump Discharge Check Valve is now also tested with air and we therefore withdraw this request for exemption.

C=OTON EDCON COMPANY Mr. Thomas A. Ippolito, Chief October 27,1980 Page 3 Acceptance Criteria Technical Specification 4.7. A.f.3 "Any one penetration or isolation valve excent main steam line isolation valves 5% Lto (45)".

High Pressure Coolant Injection (HPCI) Pump Discharae Valve (AO-2301-7)

The HPCI Pump Discharge line taps into the Feedwater injection piping between the inboard and outboard Feedwater Check Valves in Looo 'B'.

Since the reauest for exemption has been withdrawn for the Loop 'B' Feedwater Check Valves (Pene-tration 98) (See Response to Item 2.1), the HPCI Pump Discharge Check Valve is now also tested with air and we therefore withdraw this request for exemption.

Acceptance Criteria Technical Specification 4.7.A.f.2 "Any one penetration or isolation valve except main steam line isolation valves 5% Lto (45)".

Core Soray to Reactor Check Valves (AO-1400-9 A&B)

Indications Available Boston Edison Company operators would be alerted to a potential pipe break uostream of these check valves by observing the following in the Control Room; a.

Flow Indicator (FI-1450-4A&B) b.

Pressure Indicator (PI-1450-1A&B) c.

' Core Spray Pump A (B) Di. charge Hdr. Low Press' Alarm utilizing PS-9088 & PS-9089.

d.

'S.E. (N.W.) Quadrant Floor Leakage' Alarm utilizina LS-8016 & LS-8017.

Acceptance Criteria The Core Spray to Reactor Piping was not designed or constructed to allow testina of A0-1400-9A&B. Therefore,the Core Spray to Reactor Check Valves (AO-1400-9A&B) cannot currently be tested as per 10CFR50 Appendix J (See BECo response to Item 2.2.2, below).

Residual Heat Removal (RHR) Vessel Injection Line Check Valves (AO-1001-68A&B)

Indications Available Boston Edison Company operators would be alerted to a potential pipe break uostream of these check valves by observing the following in the Control Room:

a.

FlowIndicator(FI-1040-11A&B) b.

Flow Indicator (FI-1040-1A&B) c.

'RHR Pump A&C (B&D) Low Press' Alam utilizina PS-9086&9087 d.

' Containment Spray Low Flow' Alarm utilizing FS-1001-76A&B e.

'S.E. (N.W.) Quadrant Floor Leakage' Alam utilizing LS-8016 & LS-8017.

CO3 TON E'DCON COMPANY Mr. Thomas A. Ippolito, Chief October 27,1980 Page 4 Acceptance Criteria The Residual Heat Removal piping was not designed or constructed to allow testing of A0-1001-68 A&B. Therefom,the Residual Heat Removal Vessel Injection Line Check Valves ~(AO-1001-68A&B) cannot be tested as per 10 CFR 50 Appendix J(See BEco, re-

)

sponse to Item 2.2.2, below).

Itea 2.2.2 The purpose of this question as clarified by the NRC Project Manager is to provide assurance that the A0 check valves in each line will remain water covered after an accident and thereby limit reverse direction flow until the associated upstream i

MOT s are closed.

At PNPS, the A0 check valves installed on the HPCI, RCIC and Reactor Water Cleanup Return are tested for leakage in accordance with Appendix J.

Although the above valves are not considered containment isolation valves (Ref. b)) the fact that these lines run in parallel with the feedwater lines necessitate integrated leak testing as performed on the feedwater check valves to assure that the combined results are within Appendix J limits. Data from these tests provides risurance that leakage is small enough to limit reverse flow during post-accident conditions.

No testing program is currently required for the Core Spray and RHR check valves (Ref, b)), however, an engineering evaluation to determine a possible method for future leak testing of these valves has been initiated, the results of which will be famarded to you upon completion.

Additional Item 2.2.1 Additionally, provide the following infomation needed to complete all aspects of this review:

1.

For each of the penetrations involved (9a, b; 16a, b; Sla, b) identify the valves installed to perfom a containment isolation function in accordance with General Design Criterion 55 (10 CFR 50, Appendix A).

2.

Indicate the location (inside or outside containment), type valve, and auto-matic features for each of the valves of paragraph 1 above.

Response 1 & 2 Reference b) previously identified valves which perform a containment isolation function and those valves disqualified as such, including type, location and features.

Section 5.2.3.5.1 of the Pilgrim Nuclear Power Station, Final Safety Analysis Report, as stated in part, " Automatic isolation valves, in the usual sense, are not used on the inlet lines of the reactor core and containment cooling systems, i

l and reactor feedwater systems, since operation of these systems is essential following a design basis loss-of-coolant accident. Since normal flow of water in l

these systems is inward to the reactor vessel or to the primary containment, check valves in these lines will provide automatic isolation if necessary", provides the justification for compliance with GDC 55; which, allows for other containment

.l isolation provisions for specific identified classes of lines.

l

i C=CTON EDCON COMPANY Hr. Thon as A. Ippoli+o, Chief October 27,' 1980 Page 5

)

We believe this additional infonnation is adequate for you to complete your review on this subject; however, should you have additional questions or concerns please contact us.

Very truly yours,