- O.
DOCKET NO. 50-336 1
ATTACHMENT 2 MILLSTONE NUCLEAR POWER STATION, UNIT NO. 2 i
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT FOR 1978 i
i i
i i
i a
1 i
1 5
l d
i l
4 1
i i
i SEPTEMBER, 1980 Y
- *1oooo g7g
e e
Millstone Unit No. 2 (1)
Location should read 3.2 Miles WSW New London.
(2) Measurements and Approximations of Total Radioactivity a) Unit 2 Vent Total cc's out the Unit 2 vent per month is multiplied by the isotopic concentrations as measured by gamma spectrometer GE(L1) analysis of grab samples of gases, lodine, and particulates to obtain total pCi released from the vent.
t b) Containment Purges Grab samples are taken for gaseous, particulate, and iodine.
These are analyzed on GE(Li) gamma spectrometer and concentrations computed. Computed concentrations are then multiplied by the purge volume for total pCi released.,
Tritium collection is by the gas washing bottle method. The sample is counted on a liquid scintilation counter. Concentration is computed using worst possible case, 100% humidity.
Concentration is multiplied by volume purged to give total pCi released..
c) Liquid Effluents There are.three tanks which are used to discharge liquids containing radioactivity to the environs. They are one Aerated Waste Monitor Tank and two Coolant Waste Monitor Tanks.
Prior to release, the tank is recirculated for two tank volumes, a one liter sample is drawn and analyzed on the GE(Li) gamma spectrometer for individual radionuclide composition. An aliquot of the sample is analyzed for Tritium in pCi per cc.
The pCi per cc is multiplied by the cc's released to obtain total pCi released.
The. sample is retained for composite analysis for Sr-89, 90 and gross alpha. The composite contains proportional amounts of each discharge.
(3)
Batch Releases, Quarters 1 and 2 A.1 195 A.2 1.82E04 A.3 3.15E02 A.4 9.30E01 I
A.5 5.00E01 A.6 N/A - Ocean Site
e
' (4)
Batch Releases - Caseous Waste Gas Decay Tanks Number of Batch Releases 3
B.2 1.04E03 B.3 4.25E02 B.4 3.45E02 B.5 3.00E02 l
(5)
Containment Purges Number of Purges 13 2.
Total time period for purge releases (min.)
1.64E04 3.
Maximum time period for a purge (min.).
3.69E03 4.
Average - time period for a purge (min.)
1.26E03 i
5.
Minimum time period for _a purge (min.)
5.00E00 i
(6) Abnormal Releases A.
None B.
None (7) -Batch Releases, Quarters 3 and 4 A.1 148 A.2 1.49E04 A.3 9.07E02 A.4 '
1.00E02 A.5 4.00E01 A.6 N/A - Ocean Site (8) Batch Releases - Cadeous l
Waste Gas Decay Tanks Number of Batch Releases 4
I B.2 2.93E03 B.3 1.40E03 B.4 7.32E02 B.5 3.03E02 (9) Containment Purges l
Number of Purges 9
2.
Total time period for purge release (min.)
1.71E03 3.
Maximum time. period for a purge (min.)
3.10E02
(
4.
Average time period for a purge (min. )
1.40E02 5.
Minimum time period for a purge (min.)
5.00E00 r
0
. (10) Abnormal Releases 1
.A.
None B.
None (11) Gaseous Effluents - Summation of All Releases Quarter 1 Quarter 2 Est. Total % Error-A.3 N/R B.3 N/R N/R N/R c.3 N/R C.4 N/D N/D N/R D.1 N/D N/D N/R D.2 N/R N/R N/R D.3 N/R N/R N/R
- Reported under Millstone Unit No. 1 effluents.
(12) Gaseous Effluents Summation of All Releases Quarter 3 Quarter 4 A.3 B.3 N/R N/R C.3 C.4 N/D N/D i
D.3 N/R N/R f
- Reported under Millstone Unit No. 1 effluents.
l (13). Delete all values for elevated release of' gaseous effluents, j
continuous mode, Quarter 2 l
(14) Caseous Effluents, Ground Release, Continuous Mode for Quarter 1, Under particulates, Delete H-3 and curie Value j.
Delete all "<" values and enter N/D First Quarter Tritium, enter N/D Add Under Continuous Mode Quarter 2:
Fission Gases Ar-37 2.13E01 Kr 1.41E01 Xe-133 5.04E02 i
l t
['
'I-131 5.80E-04 I-133 1.33E-03 I-135 3.70E-04 Particulates Ba-La-140 N/D Co-60 2.99E-05 1-Gross alpha-N/D I-131 7.77E-06 Sr-89 2.38E-06 4
Sr-90 4.73E-06 Tritium N/D (15) Gaseous effluents, Ground Release, Continuous Mode for Quarters 3 and 4 Particulates: Delete H-3 and Curie Values 2
Delete all "<" values and enter N/D
+
Enter for Tritium - 1.69E01 and 2.27E01 for Quarters 3 and 4 (16) Liquid ef fluents, Continuous and Batch Mode for Quarters 1 - 4 Delete all "c" values and enter N/D Batch Mode, Quarter 4, for H-3 should read 7.20E01 (17) Liquid effluents, Summation of all Releases, Quarters 1 and 2:
Estimated Total Error %, Enter N/R in all Locations B.3 N/R N/R C.3 N/R N/R D.1 N/D N/D Quarters 3 and 4:
C.3 N/R N/R D.1 -
N/D N/D (18) Solid Waste and Irradiated Fuel Shipments, Jan to June A.l.C None A.l.D None Add:
l 3.
Solid Waste Disposition Number'of Shipments Mode of Transportation Destination 8
Truck (Sole Use)
Barnwell, SC July - Dec.
A.l.C None A.l.D None g
-7
,-p.-
n - - -,,,,,
u n- - +- -
--g
-