05000339/LER-1980-048-03, /03L-0:on 800828,performing Insp,Technicians Discovered Feed Flow Square Root Comparator Card Out of Calibr.Cause Undetermined.Card Recalibr & Returned to Svc

From kanterella
(Redirected from ML19338D646)
Jump to navigation Jump to search
/03L-0:on 800828,performing Insp,Technicians Discovered Feed Flow Square Root Comparator Card Out of Calibr.Cause Undetermined.Card Recalibr & Returned to Svc
ML19338D646
Person / Time
Site: North Anna 
Issue date: 09/16/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19338D632 List:
References
LER-80-048-03L-02, LER-80-48-3L-2, NUDOCS 8009230600
Download: ML19338D646 (2)


LER-1980-048, /03L-0:on 800828,performing Insp,Technicians Discovered Feed Flow Square Root Comparator Card Out of Calibr.Cause Undetermined.Card Recalibr & Returned to Svc
Event date:
Report date:
3391980048R03 - NRC Website

text

m_,;w.

a-..,au w..

..... ~

t e

i

~U.S. NUCLEAR REGULATORY C0tRfISSION E

^

1 LICENSEE EVENT REPORT ;

' CONTROL:BLOCE /1/ / / /'/'/-(1)

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)i 1

/0/1/
/V/A/N/A/42[ (2)-
/0/0/-/0/0/0/0/0/-/0/0/-(3)-

/4/1/1/1/1'(4)-

/ / ' /. (5)

LICENSEE SE-

' LICENSE NUMBER LICENSE TYPE

. CAT.

/0/1/:

/0/5/0/0/0/3/3/9/~ (7)

'/0/8/2/8/8/0/- '(8) /n/e/1/s/n/n/ (9) i/L/ (6)~

DOCEET NUMBER

~ EVENT DATE REPORT DATE

' EVENT DESCRIPTION ANDl PROBABLE CONSEQUENCES (10) r/0/2/

/ 'While performina a inspection. technicians discovered.a feed flow square rcot /

~

/0/3/

f/

comparator card'to be out of calibrationi The' affect'ed channel would not have /

-/0/4/:

/

initiated a'~ steam flow feed flow mismatch' trip sianal at'the required rate

/

- :/0/5/

/-

difference of 1.6 E+6 lbs/hr but at a nonconservative value'of 3.2 E+6 lbs/hr. /

/0/6/.

/ 'Since there was a redundant' protection channel in the loop, and the-affected

/

./0/7/

/

channel-was placed-in the tripped mode within one hour (T.S. 3.3.1.1), the _/

//0/8/

/

health and safety of the public were~not affected.

/

~

SYSTEM

CAUSE

.CAUSE COMP.

VALVE.

Cr IE '

CODE-SUBCODE ' COMPONENT CODE SUBCODE SUBCODE T/0/9/

' /I/B/~(11) /E/ (12) /G/ (13) /I/N/S/T/R/U/.(14) g/ (15) fZ/ (16)

SEQUENTIAL OCCURRENCE REPORT REVISION LER/R0 EVENT YEAR REPORT NO.

CODE.

TYPE NO.

-(17) REPORT NUMBER

/8/0/

/-/ /0/4/8/

/\\/

/0/3/

/L/

/-/

[0/

ACTION FUTURE EFFECT

' SHUTDOWN ATTACHMENT NPRD-4 PRIME COMP. COMPONENT TAREN ACTION ON PLANT METHOD

' HOURS.

SUBMITTED FORM SUB. SUPPLIER MANUFACTURER

/E/ (18) /Z/ (19) /Z/ (20) /Z/-(21) /0/0/0/0/ (22) g/ (23) /N/ (24) /N/ (25) /W/1/2/0/ (26 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS (27) f/1/0/-

/

The reason -the comparator card as out of calibration has not been determined = /

w

/1/1/~

/' -The card was recalibrated, tested several times for satisfactcry performance, /

l/1/2/

/ -and returned to service. Another' calibration check performed a week later

/

?/1/3/

/

found the comparator' card to be functionina-satisfactorily.

/

-/1/4/

/-

/

FACILITY METHOD OF-

' STATUS

% POWER

'/1/5/

./B/-(28)

'/0/3/3/ (29). OTHER STATUS

/ (30) DISCOVERY DISCO M DESCR M ION (32)

/

NA '

/B/ (31)

/ ' ROUTINE INSPECTION

/

ACTIVITY-CONTENT

,. RELEASED OF RELEASE AMOUNT OF' ACTIVITY (35)

LOCATION OF RELEASE (36)

/1/6/

/Z/ (33), /Z/-(34)' /

NA

/

/

NA

/

PERSONNEL EX1'OSURES NUMBER TYPE-DESCRIPTION-(39)

?11/7/ - L /0/0/0/ :(37)'/Z/i(38) t / :

NA

/

PERSONNEL ~ INJURIES

. NUMBER

. DESCRIPTION (41)-

/1/8/;;/0/0/0/'(40) /c 1NA

/

LOSS OF OR DAMAGE.TO FACILITY

'f iTYPE.

-. DESCRIPTION.

'/1/9/ ' [Z[;(42) J/

fNA

/

f

< PUBLICITY-

..,...! ISSUED 1..;DESCRIPTIONI(45);

NRC USE ONLY

, /2/0/[ ?/N/ (44) M/-'

NA:

/ ' / 7 / / / /:/ / / /-/~

NAlE OF PREPARER.

iW. R.iCARTWRIGHT)

' PHONE

'(703) 894-5151 50:0[9260600 a

m 4

y

g,-

(

~

,s.

Y Virginia Electric and Power. company

. North Anna Power Station, Unit 2-~

Attachment: Page 1 of 1

- Docket No. 50-339 V

Report No. I,ER 80-048-

Description of Event

on August'28,:1980 while operating in Mode 1 at 33% power a routine inspection was' performed by the Instrument Department during which a feed flow square root converter card was discovered to be out of calibration.

. Reportable pursuant to T.S. 6.9.1.9.A.

Probable Consequences of Occurrence.

The affected. protection channel would not have initiated the steam flow >' feed flow trip: signal at the proper flow rate difference of.1.6 E+6 lbs/hr as: specified.in Table 2.2-1 item no.14 in the' Technical Specification,)but at a nonconservative value of 3.2 E+6 lbs/hr. Since i

a redundant channel was ~ available to initiate the steam flow feed flow mismatch signal at the proper time, and the affected channel was placed in the tripped condition within one hour as specified by T.S. 3.3.1.1, the health and safetyLof the public were not affected.

' Cause of Event The reason the squara root comparator card was out of calibraton has not been determined.

Immediate Corrective Action

The channel affecced by this computation module was placed in.the tripped condition. The camparator card was recalibrated, tested satis-factorily, and returned to service.

- Scheduled Corrective Action The.comparator card was recalibrated a week later and found to be

. functioning properly.

- Action Taken'to Prevent Recurrence No further action are.necessary.

Generic' Implications

.There are no generic Laplications.

1

l t
- J

~

~

+

4 yc( g-e -,

  • c F

= - + - - -

V