ML19338D595

From kanterella
Jump to navigation Jump to search
Forwards Revision 1 to IE Bulletin 79-26, Boron Loss from BWR Control Blades. Written Response Required
ML19338D595
Person / Time
Site: Brunswick  
Issue date: 08/29/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Jackie Jones
CAROLINA POWER & LIGHT CO.
References
NUDOCS 8009230526
Download: ML19338D595 (1)


Text

.

paan

+

UNITED STATES E'

o't NUCLEAR REGULATORY COMMISSION

,E REGION 11 e

~#

101 MARIETTA sT.. N.W.. SUITE 3100 ATLANTA, GEORGIA 30303 AUG 2 91980 In Reply Refer To:

I:JP0s 50-325 50-324 Carolina Power and Light Company ATTN:

J. A. Jones Senior Executive Vice President and Chief Operating Officer 411 Fayetteville Street Raleigh, NC 27602 Gentlemen:

.I The enclosed IE Bulletin No. 79-26, Rev. 1, is forwarded to you for action. The original IE Bulletin No. 79-26 has been revised to adjust the required completion date for reporting the results of examination of an exposed control blade and to correct a typographical error. The revision is identified by use of "R1" in the right margin.

In order to assist the NRC in evaluating the value/ impact of each Bulletin on licensees, it would be helpful if you would provide an estimate of the manpower expended in conduct of the review and preparation of the report (s) required by the Bulletin. Please estimate separately the manpower associated with corrective actions necessary following identification of problems through the Bulletin.

A written response is required. If you desire additional information regarding this matter, please contact this office.

I Sincerely, k

w,' @ '

a J

es P. O Reilly Di ector

Enclosures:

1.

IE Bulletin No. 79-26, Rev.

2.

List of Recently Issued IE Bulletins cc w/ enc 1:

A. C. Tollison, Jr., Plant Manager so09230526

SSINS No.: 6820 Accession No.:

UNITED STATES 8006190042 NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 29, 1980 IE Bulletin No. 79-26 Rev. 1 BORON LOSS FROM BWR CONTROL BLADES Description of Circumstances:

The General Electric Company (GE) has informed us of a failure mode for control blades which can cause a loss of boron poison material. Hot cell examinations of both foreign and domestic blades have revealed cracks near the upper end of stainless steel tubing and loss of boron from the tubes.

The cracks and boron loss have so far been confined to locations in the poison tubes with more than 50 percent Boron-10 (B 0) local depletion. Observed crack sizes range from a quarter to a half inch in length and from one to two mils in width.

GE has postulated that the cracking is due to stress corrosion induced by solidification of boron carbide (B C) particles and swelling of the compacted 4

B C as helium and lithium concentrations grow. Once primary coolant penetrat.s 4

the cladding (i.e., the cracking has progressed through the cladding wall and the helium-lithium pressures are sufficient to open the crack), boron is I

leached out of the tube at locations with more than 50 percent B local depletion (local depletion is considered to be twice the average depletion).

It was further found with similar cracking but with less than 50 percent local depletion of B, that leaching did not occur even though primary coolant had penetrated the cladding.

The cracking and boron loss shorten the design life of the control blade.

According to the GE criteria the end of design life is reached when the reactiv percent, which corresponds to quarter of the control blade.