05000296/LER-1980-026-03, /03L-0:on 800714,RCIC Min Flow Bypass Valve, FCV-3-71 Failed to Close on Signal from Manual Control Switch.Caused by Dirty Torque Switch Contacts.Contacts Cleaned & Limitorque Size SMB-000 Returned to Svc

From kanterella
(Redirected from ML19338C394)
Jump to navigation Jump to search
/03L-0:on 800714,RCIC Min Flow Bypass Valve, FCV-3-71 Failed to Close on Signal from Manual Control Switch.Caused by Dirty Torque Switch Contacts.Contacts Cleaned & Limitorque Size SMB-000 Returned to Svc
ML19338C394
Person / Time
Site: Browns Ferry 
Issue date: 08/11/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19338C388 List:
References
LER-80-026-03L-03, LER-80-26-3L-3, NUDOCS 8008150345
Download: ML19338C394 (2)


LER-1980-026, /03L-0:on 800714,RCIC Min Flow Bypass Valve, FCV-3-71 Failed to Close on Signal from Manual Control Switch.Caused by Dirty Torque Switch Contacts.Contacts Cleaned & Limitorque Size SMB-000 Returned to Svc
Event date:
Report date:
2961980026R03 - NRC Website

text

-

n

'V

..m. r on.m

....m,... a s u v u. u - - - --

17 77)

LICENSEE cvi.

riEPCAT cCntact s.acie LJ l

I I 'O

( ease rain' oa rvas a'i. aeou'aco iNronaatioN>

1 6

Ll B i R l F l 3 l@s l0 l-la l0 i0 10 l0 l- !O l0 l@l4l1l1l1l1j@ [_[j @

% U. _..cENstE co,E ie uCE :E wveEa a

uC E.m 1,,E Jo

,A.

2 cow.

I o I i]

C"[E ! LMIO l 5 10 l0 10 l2 19 l6 @l0 17 11 14 18 10 @l 0 l 8 l 1 l 1 I 8 ll.j@

76 RE* ORT c Af r P2

/

6C 61 CoCKET NbutE R 68 69 EVENT D ATE EVENT DESCRIPTION AND pao 6ABLE CONSEQUENCES h 101.] (During normal coeration while performine SI 4. 5.F.1.C the RCIC minimum flow ),, mass

[ u i s I t valve, FCV-3-71-34, failed to go closed on signal f rom manual control switch.

~

[og g @ ference T.S. 3.5.F.2.

HPCI was verified operable. There were no significant l ; g gesulting events. There was no danger to health or safety of public. Previous 3 FRO-50-259/79028.

opjjevent

[o l ] I t r J L_-

s v *. T E M wAUSE CALSE C 04* P vALs E C70E COCE eseCCCE GCYPCNE NT COCE SLeCOCE SL9COC1 131 j l Cl El@ [Ejh [XJ h l V l A l L lV l0 lP lh [,Ajg g @

't 10 11 12 13

?4 19 20 SEQUEN11 AL OCCv H alt '.C.t m E 'OR T HL*

vp%TvE4e wt PORT NU CODE f**E N-

@ m,y mg 1s l0 l l_l l 0l 2l 6; y

l 0l 31 lLl l_l l OJ g

oar il 22 23 24 26 2r 28 23 JO Je s.C f UN ttfUns E F 8 28. 7 LwuYCOWN Af7ACwvrNT NP eiD-4

'AIVE CSOP

- ' ' 3 ".*. f N f f aa 7.

ACT17.

ON pt at.T YEtudo

=OLAS SU8vlTTED FOHu ;ew0 SL **U E R

    • M fa,fu"T

(, B j glJ4zlg g

]4@

l 0 l0 l0 l ]@

lN l@

l Nl@

l Ll2 l0[0 1

40 el 42 43 44 C A JSE DESCRioT.0!. ANO CCaRECTi% E t.CTiONS

,il ] [FCV-3-71-34', failed to go closed due to dirty torque switch contacts. The torque

., i ] [ switch contacts were cleaned and the val ~ve. Limitorque si
:e SMB-000, returned to

. service. This is a random occurrence with no high incidence rate for similar valves,

] { no recurrence control required.

Iii 1 1._

i 9

,Y N

  • A PC AER OfwfasfAruS
COV HV D.SCOVERY DESC*. a t,vg xi I

U OI I' il LrJ@ l o i c 19161 c, - 4 4 4 -, ~

shn:rv us TENT nf Lf tie 3 Os aE LE ASF AMOUNT CF ACTivi v LOC 47'3N 08 RELE ASE f

l'I' NA NA

  • 9 10 11 44 45

%muNNE L 6.*f>5U8b

.- *. et E A fvPE DE St Hip T*0N 1 > i ] ! O I o I 0 l@l Z l@l NA JEeCNNE iNJun ES 7 "st a DESCHiP f iCN NA 1

Iiji01010l@l

>2

,8 ),

r,p ps- [ Avgh( TO p aJ Lg7y

~

foe uf C4aPTION i'l]Izi@l NA

~

  1. # 1 ~2 I Y NAC M.'j(Y

,of A %.R s a t itr%

NA l

!llllll1ll!'!

l. I ] L, Nj@l 69 69 10 395 8 nag 7 3 g

...csc

..wr or,,e

~

a e

Tennessee Wlh y Authority rm.a ny-n Brarer.s Ferry Nuctenr Plant DF :~ 2 1/10 0; LER SUPPLEMENTAL INFORMATION B FRO 196 /_,,gpq26 Technical Specification Involved 1.5.F.2 Reported Under Technical Specification 6.7.2.5 (2)

Date of Occurrence 7/14/80 Time of Occurrence 0930 Unit 3

Identification and Description'of' Occurrence.

RCIC ntnimum flow bypass valve, FCV-3-71-34, failed to go closed on sinal f rom manual centrol switch.

Conditions Prior to Occurrence:

Unit 1 0 82,*,

Unit 2 0 89%

Un it 3 0 49%

Action specified in the Technical Spec facation Survettlar.cc hepairemer. s m o

<Ju : to inogerglak equipment. Describe.

Ccmpleted surveillance tests en HPCI system.

s)ppgrrnt Cause of Occurrer.re:

Valve failed to go c'.osed due to dirty torque switch cantacts.

Analvsis of Occurrence:

There vaa no damage to plant eq u. ;tr.en t. Bere sa4 no activity r 21 case. c o peerse inel exposure or injury and no danger to the health or safety of 'he aublic.

C..rrective Action :

Conucts we re cleaned.

1

\\

' tilure Data :

j Briw-5C-239/79028 i

"INten tion, geriod - Lifeti::c; Responsibility - Adminia:ative Supe: ciser l

Vh

  • R avic.an :

h- - - -.

, -- p.

0