ML19337A483

From kanterella
Jump to navigation Jump to search
Ack Receipt of Re Part 21 Rept on post-LOCA Deuterium Analyzers.Matter Will Be Reviewed During Insp Despite Util Statement That Matter Is Not Reportable Per 10CFR50.55(e)
ML19337A483
Person / Time
Site: Perry  
Issue date: 09/08/1980
From: Fiorelli G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Davidson D
CLEVELAND ELECTRIC ILLUMINATING CO.
References
REF-PT21-80-267-001 NUDOCS 8009290071
Download: ML19337A483 (1)


Text

I.

=

tma acI&g UNIT ED STATES (p

[0,,

NUCLEAR REGULATORY COMMISSION

((b Q

o R EClON lli U

f 799 ROOSEVELT ROAD cLEN sttvu, ett:Nois sois7 SEP -- 8 1980 Docket No. 50-440 Docket No. 50-441 The Cleveland Electric Illuminating Company ATTN: Dalwyn R. Davidson Vice President - System Engineering and Construction Post office Box 5000 Cleveland, OH 44101 Gentlemen:

Thank you for your letter dated August 29, 1980 regarding a Part 21 report concerning Post-LOCA H Analyzers. We understand your letter 7

to state that you do not consider this to be a significant deficiency or reportabic defect under the requirements of 10 CFR 50.55(e) or Part 21.

However, we will review this matter during a future inspection as part of our followup on the Comsip, Inc. Part 21 report.

Your cooperation with us is appreciated.

Siacerely, b

G. Fiorelli, Chief Reactor Construction and Engineering Support Branch cc w/1tr dtd 8/29/80:

Central Files Reproduction Unit NRC 20b PDR Local PDR NSIC TIC Harold W. Kohn, Power Siting Commission Mr. Daniel D. Wilt, Attorney llelen W. Evans, State of Ohio 1

8009 2 9 00N S

.-y-

P O BOX 5000 m CLEVELAND. OHIO 44101 e TELEPHONE (216) 622 9800 e ILLUMINATlNG BLDG e

SS PUBLIC SOUAAE

'"U

' #'e Na: ion Dafwyn R. Davidson August 29, 1980 v,Ci enesios N, Sv5ff u (NGiNE ER>NG ANO CONST AUCTION Mr. James G. Keppler Director Region III Office of Inspection and Enforcement U.S. Nuclear Regulatory Comission 799 Roosevelt Road Glenn Ellyn, IL 60137

Dear Mr. Keppler:

'lhis letter is in reference to the Ccansip, Inc. letter, dated July 31, 1980, to Mr. R. H. Engelken, Director Region V, concerning a possible reportable defect under the requirements of 10CFR, Part 21, (see attached). Additionally, our final report on another deficiency conceming Post-IOCA H2 Analyzers, dated August 26, 1980, sent to you, identified this problem.

During an in-house functional test of a Post-IOCA H2 Analyzer at Comsip, Inc.,

the drive shaft of a Reliance IE motor driving a Dia-Vac diaphragm pump snapped in two (2) places. Based on 10CFR50 55(e), Item IV and our Quality Assurance Program requirements, if a vendor reports a Part 21 noncompliance or defect on 1

a Perry Nuclear Power Plant item or activity, CEI is required to report a

)

l significant deficiency, if our evaluation of the problem concurs, it could be a substantial safety ha-M.

l Subsequent to review by our Engineering and Quality Assurance Departments, the analyzer malfunction was not deemed a significant deficiency, since it only monitors hydrogen concentration and does not provide any automatic control In the un1n ly event that the redundant analyzer would also be functions.

e rendered inoperable, the other components of the combustible gas contml 4

system, (hydrogen reccabiners and back-up purge systems), can be started, allowin6 sufficient time for repairs of the hydrogen analyzer or to manually obtain and analyze for hydrogen. Our review has detemined that a possible significant deficiency or reportable defect does not exist under the require-ments of 10CFR50 55(e) and/or Part 21.

Very truly yours, 127

/

e

=

Dalwyr). Davidson Vice President System Engineering and Construction DRD:deg T10/U/1 Attachnent cc: Mr. Victor Stello, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Comission Washington, D.C. 20555 SEP 0230 tocli2.0297 c

l *,)

. -~:,.. e v

  • n g

1418 E.Undsn Avenus RO.Bos152

,/,

g

'm Unden, NJ 07036

$5?' ]

?

10650 E. Rush Street South El Monte, CA 91733 f

...i.

(213)442 0882 Telex 67 4768 f

July 31, 1980 Mr. Robert H.Engelken Director, Region V Office of Inspection and Enforcement U.S.

Nuclear Regulatory Commission 1990 N.

California Boulevard, Suite 202 Walnut Creek, California 94596

Subject:

Possible Existence of Reportable Defect Under Requirements of Code 10 Federal Regulations Part 21.

1 i

Dear Sir; As required by the subject regulation, the following report is issued in triplicate.

"irm Identification:

Comsip, Inc.

Delphi Systems Division 10650 East Rush Street South El Monte, California 91733 Telephone (213) 442-0882 Responsible Officer making Report:

Wayne Mercer, General Manager Delphi Systems Division Pesponsible 10CFR21 Committee:

A.

Robinson Technical Director G.

Gillette Project Engineer Manager J.

Pugh Corporate 0.A. Manager Type of Business Activity:

Manufacturer of Monitoring Systems of Gases within the Containment 3uilding.

DUPLICATE DOCUMENT l

l Entire document previously entered into system under:

SEP 02198g ANO MMI D Mb N o. of pages:

. - - _