Part 21 Rept Re Drive Shaft of Reliance IE Motor Driving Dia-Vac Diaphragm Pumps Which Stopped in Two Places During in-house Functional Test of post-LOCA Hydrogen Analyzer. Deficiencies Not Reportable Per 10CFR50.55(e) or Part 21
ML19344F021
Person / Time
Site: Perry  
Issue date: 08/29/1980
From: Davidson D
CLEVELAND ELECTRIC ILLUMINATING CO.
To:
References
REF-PT21-80-267-001 10CFR-050.55E, 10CFR-50.55E, NUDOCS 8009120297
Download: ML19344F021 (2)


Text

m

,mm.m

.m

-m. _

PART 21 IIBfIIFICATIEi NO.

Bo-?Fi-oo 1 C0 PAW [WEChelas flui INE OF ETTER. (zalte D03ET10.

Bio-44eI44i INTE DISTRIBtfiED Alulto ORIGIIML EPORT SLPPlBBfiARY X DISTRIBUTIGh EACTOR @ 5 FLEL CYCLE &

S/FEGUARDS (S)

I'AN

  • IE FILES IE FILES AD/RDI (2)

IE FILES AD/SG AD/RCI O AD/ FREI AD/RDI EGIGG I,II,III,IV,V EGIONS I,II,III,IV,V EGI0fG I,II,III,IV,V VENDOR BR, R-IV VdiDDR BR. R-IV

\\EiDDR BR. R-IV LOEB / FPA FIB 5715 fiSS / FO E SS-396 NRR/ DOL AEOD FIB 7602 LCEB/ PPA PTB 5715 g,ES / SG SS-881 NRR/ffE AEDD FIG 7602 UEB / PPA PIB 5715 NRR/DSI dSLBP FAf 450 AEOD FIG 7602 NRR/IET SAP /SP ffB-7210A ASLBP E/W 450 -

ISR/ DOL CEhTPAL FILES 016 CENTRAL FIES 016 l

j ASLBP E/W 450 CENTPAL FILES ( GR000 CBiTRAL FILES (DiR0tD CBiTRALFILES 016 PDR CEhTPAL FIES SS-395 CENTRAL FILES (DiR000 LPDR PDR PDR 10%

LPDR LPDR TERA k

THIS DOCUMENT CONTAINS P0OR QUAL.lTY PAGES A

PRELIMItMRY EVALUATION OF TiEATTACHED REPORT ItOICATES LEAD RESPONSIBILITY FOR FOLL0rUP AS SFOhN BELOW:

r l

fiRR 2 IfSS E OM ROI SG

>FFMSI P3'. 8/1/80 l

80091202.T}

3

r

~l f

,. }

P o Box $000. CLEVELAND. ohio 44101

. TELEPHONE (216) 622 9900.

fLLU?.*lN ATING BLOG 55 PUBLIC SOUAf)!

~

- we-Aueust 29,19e Sv&TE u (NGsNttninG AND CON $1RUCilON Mr. James G. Keppler 9

Director Re61on III Office of Inspection and Dforcement 9

U.S. Nuclear Rc6ulatory Co=sission i.

9 799 Roosevelt Road i

G1cnn Ellyn, IL 60137

Dear Mr. Keppler:

'Ihis letter is in reference to the Corsip, Inc. letter, dated July 31, 1930,

.to Mr. _R. H. Dgelken, Director Region V, concerning a possib1e reportable defect under the requirements of 10CFR, Part 21, (see attached). Additionally, our final report on another deficiency conceniing Post-IOCA H2 Analyzers, dated August 26,1980, sent to you, identified this problem.

Dttring an in-house functional test of a Post-IOCA H2 Analyzer at Cc= sip, Inc.,

the drive shaft of a Reliance IE motor driving a Dia-Vac diaphra6m pu=p snapped in two (2) places. Based on 10CFR50 55(e), Item IV and our Quality Assurance

. Program require =ents, if a vendor reports a Part 21 nonco=pliance or defect on a Perry Nuclear Power Plant item or activity, CEI is required to report a significant deficiency, if our evaluation of the probics concurs, it could be a substantial safety ha:ani.

Subsequent to review by our Dgineering and Quality Assurance Departments, the cualyzer malfunction was not deemed a significant deficiency, since it only monitors hydmgen concentration and does not provide any auta=atic contml functions. In the unlikely event that the redundant analyzer would also be rendered inoperable, the other co=ponents of the co=bustible cas control system, (hydmgen reco=biners and back-up purge syste=s), can be started, l

allowing sufficient tir.e for repairs of the h>-drogen analyzer or to manually obtain and analyze for hydrogen. Our review has determined that a possible significant deficiency or reportable defect does not exist under the require-rents of 10CFR50.55(e) and/or Part 21.

Very truly yours, Vti Is My Dalwy!) R. Davidson Vice President System Engineering and Construction DRD:,1eg T10 1

Attachnent cc: Mr. Victor Stello, Director Office of Inspection and Enforcement U.S. Nuclear Regu1ato:7 Cocr.ission 7

l Washington, D.C. 20555

~

..-*.e e sa - n C

,s 1418 E. Linden Avenue J

t P.O. P.c: 152 Unden.NJ 07036

,f a

n

3 #

UlE~?!.,5-g

~ 10CSO E. Rush Street N

South Ell.tonte. C A 91733

~

..?

=

p.

(213)442-0882 Telex 67 4768 f

July 31, 1980

~

Mr. Robert H.Engelken D

Director, Region V Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission 1990 N.

California Bou?tvard, Suite 202 Walnut Creek, California 94596

Subject:

Possible Existence of Reportable Defect [nder Requirements of Code 10 Federal Regulations Part 21.

Dear Sir;

~

l As required by the subject regulation, the following report is issued in triplicate.

Firm Identification:

Comsip, Inc.

Delphi Systems Division 10650 East Rush Street South El Monte, California 91733 Telephone (213) 442-0882 Responsible Officer making Report:

Wayne Mercer, General Manager Delphi Systems Division

A. Robinson Technical Director G. Gillette Project Engineer Manager J.

Pugh Corporate Q.A. Manager l

l l-Type of Business Activity:

!a Manufacturer of Monitoring Systems of Gases within the Containment Building.

DUPLICATE DOCUMENT Entire document previously entered into system under:

h ANo $O09 / 8 O g/>

No. of

,_ _,