[7590-01-P]

NUCLEAR REGULATORY COMMISSION

[NRC-2019-0243]

Biweekly Notice Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations AGENCY: Nuclear Regulatory Commission.

ACTION: Biweekly notice.

SUMMARY

Pursuant to section 189.a.(2) of the Atomic Energy Act of 1954, as amended (the Act), the U.S. Nuclear Regulatory Commission (NRC) is publishing this regular biweekly notice. The Act requires the Commission to publish notice of any amendments issued, or proposed to be issued, and grants the Commission the authority to issue and make immediately effective any amendment to an operating license or combined license, as applicable, upon a determination by the Commission that such amendment involves no significant hazards consideration, notwithstanding the pendency before the Commission of a request for a hearing from any person. This biweekly notice includes all amendments issued, or proposed to be issued, from November 19, 2019, to December 2, 2019. This notice also incorporates the revised biweekly format as noticed in the Federal Register on December 3, 2019. The last biweekly notice was published on December 3, 2019.

DATES: Comments must be filed by January 16, 2020. A request for a hearing or petitions for leave to intervene must be filed by February 18, 2020.

ADDRESSES: You may submit comments by any of the following methods (unless this document describes a different method for submitting comments on a specific subject):

Federal Rulemaking Web Site: Go to https://www.regulations.gov and search for Docket ID NRC-2019-0243. Address questions about NRC Docket IDs in

2 Regulations.gov to Jennifer Borges; telephone: 301-287-9127; e-mail:

Jennifer.Borges@nrc.gov. For technical questions, contact the individual(s) listed in the FOR FURTHER INFORMATION CONTACT section of this document.

Mail comments to: Office of Administration, Mail Stop: TWFN-7-A60M, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, ATTN: Program Management, Announcements and Editing Staff.

For additional direction on obtaining information and submitting comments, see Obtaining Information and Submitting Comments in the SUPPLEMENTARY INFORMATION section of this document.

FOR FURTHER INFORMATION CONTACT: Lynn Ronewicz, Office of Nuclear Reactor Regulation, 301-415-1927, e-mail: Lynn.Ronewicz@nrc.gov, U.S. Nuclear Regulatory Commission, Washington DC 20555-0001.

SUPPLEMENTARY INFORMATION:

I.

Obtaining Information and Submitting Comments A. Obtaining Information Please refer to Docket ID NRC-2019-0243, when contacting the NRC about the availability of information for this action. You may obtain publicly-available information related to this action by any of the following methods:

Federal Rulemaking Web Site: Go to https://www.regulations.gov and search for Docket ID NRC-2019-0243.

NRCs Agencywide Documents Access and Management System (ADAMS): You may obtain publicly-available documents online in the ADAMS Public Documents collection at https://www.nrc.gov/reading-rm/adams.html. To begin the search, select Begin Web-based ADAMS Search. For problems with ADAMS, please contact the NRCs Public Document Room (PDR) reference staff at 1-800-397-4209,

3 301-415-4737, or by e-mail to pdr.resource@nrc.gov. For the convenience of the reader, instructions about obtaining materials referenced in this document are provided in the Availability of Documents section.

NRCs PDR: You may examine and purchase copies of public documents at the NRCs PDR, Room O1-F21, One White Flint North, 11555 Rockville Pike, Rockville, Maryland 20852.

B. Submitting Comments Please include Docket ID NRC-2019-0243, facility name, unit nos. docket no.,

application date, and subject, in your comment submission.

The NRC cautions you not to include identifying or contact information that you do not want to be publicly disclosed in your comment submission. The NRC will post all comment submissions at https://www.regulations.gov as well as enter the comment submissions into ADAMS. The NRC does not routinely edit comment submissions to remove identifying or contact information.

If you are requesting or aggregating comments from other persons for submission to the NRC, then you should inform those persons not to include identifying or contact information that they do not want to be publicly disclosed in their comment submission. Your request should state that the NRC does not routinely edit comment submissions to remove such information before making the comment submissions available to the public or entering the comment into ADAMS.

II. Notice of Consideration of Issuance of Amendments to Facility Operating Licenses and Combined Licenses and Proposed No Significant Hazards Consideration Determination For the facility-specific amendment requests shown below, the Commission finds that the licensees analyses provided, consistent with title 10 of the Code of Federal

4 Regulations (10 CFR) Section 50.91 is sufficient to support the proposed determination that these amendment requests involve No Significant Hazards Consideration (NSHC).

Under the Commissions regulations in 10 CFR 50.92, operation of the facility in accordance with the proposed amendment would not (1) involve a significant increase in the probability or consequences of an accident previously evaluated, or (2) create the possibility of a new or different kind of accident from any accident previously evaluated; or (3) involve a significant reduction in a margin of safety.

The Commission is seeking public comments on this proposed determination.

Any comments received within 30 days after the date of publication of this notice will be considered in making any final determination.

Normally, the Commission will not issue the amendment until the expiration of 60 days after the date of publication of this notice. The Commission may issue the license amendment before expiration of the 60-day period provided that its final determination is that the amendment involves NSHC. In addition, the Commission may issue the amendment prior to the expiration of the 30-day comment period if circumstances change during the 30-day comment period such that failure to act in a timely way would result, for example in derating or shutdown of the facility. If the Commission takes action prior to the expiration of either the comment period or the notice period, it will publish in the Federal Register a notice of issuance. If the Commission makes a final NSHC determination, any hearing will take place after issuance. The Commission expects that the need to take action on an amendment before 60 days have elapsed will occur very infrequently.

A. Opportunity to Request a Hearing and Petition for Leave to Intervene Within 60 days after the date of publication of this notice, any persons (petitioner) whose interest may be affected by this action may file a request for a hearing and

5 petition for leave to intervene (petition) with respect to the action. Petitions shall be filed in accordance with the Commissions Agency Rules of Practice and Procedure in 10 CFR part 2. Interested persons should consult a current copy of 10 CFR 2.309. The NRCs regulations are accessible electronically from the NRC Library on the NRCs Web site at https://www.nrc.gov/reading-rm/doc-collections/cfr/. Alternatively, a copy of the regulations is available at the NRCs Public Document Room, located at One White Flint North, Room O1-F21, 11555 Rockville Pike (first floor), Rockville, Maryland 20852. If a petition is filed, the Commission or a presiding officer will rule on the petition and, if appropriate, a notice of a hearing will be issued.

As required by 10 CFR 2.309(d) the petition should specifically explain the reasons why intervention should be permitted with particular reference to the following general requirements for standing: (1) the name, address, and telephone number of the petitioner; (2) the nature of the petitioners right under the Act to be made a party to the proceeding; (3) the nature and extent of the petitioners property, financial, or other interest in the proceeding; and (4) the possible effect of any decision or order which may be entered in the proceeding on the petitioners interest.

In accordance with 10 CFR 2.309(f), the petition must also set forth the specific contentions which the petitioner seeks to have litigated in the proceeding. Each contention must consist of a specific statement of the issue of law or fact to be raised or controverted. In addition, the petitioner must provide a brief explanation of the bases for the contention and a concise statement of the alleged facts or expert opinion which support the contention and on which the petitioner intends to rely in proving the contention at the hearing. The petitioner must also provide references to the specific sources and documents on which the petitioner intends to rely to support its position on the issue. The petition must include sufficient information to show that a genuine dispute

6 exists with the applicant or licensee on a material issue of law or fact. Contentions must be limited to matters within the scope of the proceeding. The contention must be one which, if proven, would entitle the petitioner to relief. A petitioner who fails to satisfy the requirements at 10 CFR 2.309(f) with respect to at least one contention will not be permitted to participate as a party.

Those permitted to intervene become parties to the proceeding, subject to any limitations in the order granting leave to intervene. Parties have the opportunity to participate fully in the conduct of the hearing with respect to resolution of that partys admitted contentions, including the opportunity to present evidence, consistent with the NRCs regulations, policies, and procedures.

Petitions must be filed no later than 60 days from the date of publication of this notice. Petitions and motions for leave to file new or amended contentions that are filed after the deadline will not be entertained absent a determination by the presiding officer that the filing demonstrates good cause by satisfying the three factors in 10 CFR 2.309(c)(1)(i) through (iii). The petition must be filed in accordance with the filing instructions in the Electronic Submissions (E-Filing) section of this document.

If a hearing is requested, and the Commission has not made a final determination on the issue of no significant hazards consideration, the Commission will make a final determination on the issue of no significant hazards consideration. The final determination will serve to establish when the hearing is held. If the final determination is that the amendment request involves no significant hazards consideration, the Commission may issue the amendment and make it immediately effective, notwithstanding the request for a hearing. Any hearing would take place after issuance of the amendment. If the final determination is that the amendment request involves a significant hazards consideration, then any hearing held would take place

7 before the issuance of the amendment unless the Commission finds an imminent danger to the health or safety of the public, in which case it will issue an appropriate order or rule under 10 CFR part 2.

A State, local governmental body, Federally-recognized Indian Tribe, or agency thereof, may submit a petition to the Commission to participate as a party under 10 CFR 2.309(h)(1). The petition should state the nature and extent of the petitioners interest in the proceeding. The petition should be submitted to the Commission no later than 60 days from the date of publication of this notice. The petition must be filed in accordance with the filing instructions in the Electronic Submissions (E-Filing) section of this document, and should meet the requirements for petitions set forth in this section, except that under 10 CFR 2.309(h)(2) a State, local governmental body, or Federally-recognized Indian Tribe, or agency thereof does not need to address the standing requirements in 10 CFR 2.309(d) if the facility is located within its boundaries.

Alternatively, a State, local governmental body, Federally-recognized Indian Tribe, or agency thereof may participate as a non-party under 10 CFR 2.315(c).

If a hearing is granted, any person who is not a party to the proceeding and is not affiliated with or represented by a party may, at the discretion of the presiding officer, be permitted to make a limited appearance pursuant to the provisions of 10 CFR 2.315(a).

A person making a limited appearance may make an oral or written statement of his or her position on the issues but may not otherwise participate in the proceeding. A limited appearance may be made at any session of the hearing or at any prehearing conference, subject to the limits and conditions as may be imposed by the presiding officer. Details regarding the opportunity to make a limited appearance will be provided by the presiding officer if such sessions are scheduled.

B. Electronic Submissions (E-Filing)

8 All documents filed in NRC adjudicatory proceedings, including a request for hearing and petition for leave to intervene (petition), any motion or other document filed in the proceeding prior to the submission of a request for hearing or petition to intervene, and documents filed by interested governmental entities that request to participate under 10 CFR 2.315(c), must be filed in accordance with the NRCs E-Filing rule (72 FR 49139; August 28, 2007, as amended at 77 FR 46562; August 3, 2012). The E-Filing process requires participants to submit and serve all adjudicatory documents over the internet, or in some cases to mail copies on electronic storage media. Detailed guidance on making electronic submissions may be found in the Guidance for Electronic Submissions to the NRC and on the NRC Web site at https://www.nrc.gov/site-help/e-submittals.html. Participants may not submit paper copies of their filings unless they seek an exemption in accordance with the procedures described below.

To comply with the procedural requirements of E-Filing, at least 10 days prior to the filing deadline, the participant should contact the Office of the Secretary by e-mail at hearing.docket@nrc.gov, or by telephone at 301-415-1677, to (1) request a digital identification (ID) certificate, which allows the participant (or its counsel or representative) to digitally sign submissions and access the E-Filing system for any proceeding in which it is participating; and (2) advise the Secretary that the participant will be submitting a petition or other adjudicatory document (even in instances in which the participant, or its counsel or representative, already holds an NRC-issued digital ID certificate). Based upon this information, the Secretary will establish an electronic docket for the hearing in this proceeding if the Secretary has not already established an electronic docket.

Information about applying for a digital ID certificate is available on the NRCs public Web site at https://www.nrc.gov/site-help/e-submittals/getting-started.html. Once

9 a participant has obtained a digital ID certificate and a docket has been created, the participant can then submit adjudicatory documents. Submissions must be in Portable Document Format (PDF). Additional guidance on PDF submissions is available on the NRCs public Web site at https://www.nrc.gov/site-help/electronic-sub-ref-mat.html. A filing is considered complete at the time the document is submitted through the NRCs E-Filing system. To be timely, an electronic filing must be submitted to the E-Filing system no later than 11:59 p.m. Eastern Time on the due date. Upon receipt of a transmission, the E-Filing system time-stamps the document and sends the submitter an e-mail notice confirming receipt of the document. The E-Filing system also distributes an e-mail notice that provides access to the document to the NRCs Office of the General Counsel and any others who have advised the Office of the Secretary that they wish to participate in the proceeding, so that the filer need not serve the document on those participants separately. Therefore, applicants and other participants (or their counsel or representative) must apply for and receive a digital ID certificate before adjudicatory documents are filed so that they can obtain access to the documents via the E-Filing system.

A person filing electronically using the NRCs adjudicatory E-Filing system may seek assistance by contacting the NRCs Electronic Filing Help Desk through the Contact Us link located on the NRCs public Web site at https://www.nrc.gov/site-help/e-submittals.html, by e-mail to MSHD.Resource@nrc.gov, or by a toll-free call at 1-866-672-7640. The NRC Electronic Filing Help Desk is available between 9 a.m. and 6 p.m., Eastern Time, Monday through Friday, excluding government holidays.

Participants who believe that they have a good cause for not submitting documents electronically must file an exemption request, in accordance with 10 CFR 2.302(g), with their initial paper filing stating why there is good cause for not filing

10 electronically and requesting authorization to continue to submit documents in paper format. Such filings must be submitted by: (1) first class mail addressed to the Office of the Secretary of the Commission, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, Attention: Rulemaking and Adjudications Staff; or (2) courier, express mail, or expedited delivery service to the Office of the Secretary, 11555 Rockville Pike, Rockville, Maryland 20852, Attention: Rulemaking and Adjudications Staff. Participants filing adjudicatory documents in this manner are responsible for serving the document on all other participants. Filing is considered complete by first-class mail as of the time of deposit in the mail, or by courier, express mail, or expedited delivery service upon depositing the document with the provider of the service. A presiding officer, having granted an exemption request from using E-Filing, may require a participant or party to use E-Filing if the presiding officer subsequently determines that the reason for granting the exemption from use of E-Filing no longer exists.

Documents submitted in adjudicatory proceedings will appear in the NRCs electronic hearing docket which is available to the public at https://adams.nrc.gov/ehd, unless excluded pursuant to an order of the Commission or the presiding officer. If you do not have an NRC-issued digital ID certificate as described above, click cancel when the link requests certificates and you will be automatically directed to the NRCs electronic hearing dockets where you will be able to access any publicly available documents in a particular hearing docket. Participants are requested not to include personal privacy information, such as social security numbers, home addresses, or personal phone numbers in their filings, unless an NRC regulation or other law requires submission of such information. For example, in some instances, individuals provide home addresses in order to demonstrate proximity to a facility or site. With respect to copyrighted works, except for limited excerpts that serve the purpose of the adjudicatory

11 filings and would constitute a Fair Use application, participants are requested not to include copyrighted materials in their submission.

The table below provides the plant name, docket number, date of application, ADAMS accession number, and location in the application of the licensees proposed NSHC determination. For further details with respect to these license amendment applications, see the application for amendment which is available for public inspection in ADAMS and at the NRCs PDR. For additional direction on accessing information related to this document, see the Obtaining Information and Submitting Comments section of this document.

Table 1 - License Amendment Request(s)

Entergy Operations, Inc.; Waterford Steam Electric Station, Unit 3; St. Charles Parish, LA Application Date August 27, 2019 ADAMS Accession No. ML19239A429 Location in Application of NSHC Enclosure, Page 4 of 6 Brief Description of Amendments The amendment would revise Technical Specification Surveillance Requirements 4.7.6.1.d.2 and 4.7.6.1.d.4 to add an exception for automatic dampers and valves that are locked or sealed. The revision would facilitate fuel movement with one train of the Control Room Emergency Air Filtration System inoperable.

Proposed Determination NSHC Name of Attorney for Licensee, Mailing Address Anna Vinson Jones, Senior Counsel, Entergy Services, Inc., 101 Constitution Avenue, NW, Suite 200 East, Washington, DC 20001 Docket Nos.

50-382 NRC Project Manager, Telephone Number April Pulvirenti, 301-415-1390 Entergy Operations, Inc.; Waterford Steam Electric Station, Unit 3; St. Charles Parish, LA Application Date September 20, 2019 ADAMS Accession No. ML19263F129 Location in Application of NSHC Enclosure, Page 11 of 13

12 Brief Description of Amendments The proposed change would revise the Waterford Steam Electric Station, Unit 3, Technical Specifications (TSs) to remove TSs 3.1.2.1 through 3.1.2.8, Boration Systems, and references to the TSs, and relocate the information to the licensee-controlled Technical Requirements Manual.

Proposed Determination NSHC Name of Attorney for Licensee, Mailing Address Anna Vinson Jones, Senior Counsel, Entergy Services, Inc., 101 Constitution Avenue, NW, Suite 200 East, Washington, DC 20001 Docket Nos.

50-382 NRC Project Manager, Telephone Number April Pulvirenti, 301-415-1390 Entergy Operations, Inc.; Waterford Steam Electric Station, Unit 3; St. Charles Parish, LA Application Date October 24, 2019 ADAMS Accession No. ML19297H543 Location in Application of NSHC Page 13 of the Enclosure Brief Description of Amendments The proposed change would revise Technical Specification 3/4.8.1, A.C. [Alternating Current]

Sources - Operating, Surveillance Requirements to correct errors in some criteria for voltage and frequency. The changes would ensure compliance with the plant design basis and ensure that the Emergency Diesel Generators are capable of supplying power with the correct voltage and frequency to the required loads.

Proposed Determination NSHC Name of Attorney for Licensee, Mailing Address Anna Vinson Jones, Senior Counsel, Entergy Services, Inc., 101 Constitution Avenue, NW, Suite 200 East, Washington, DC 20001 Docket Nos.

50-382 NRC Project Manager, Telephone Number April Pulvirenti, 301-415-1390 Exelon Generation Company, LLC; Braidwood Station, Units 1 and 2; Will County, IL Application Date September 11, 2019 ADAMS Accession No. ML19254D105 Location in Application of NSHC, Section 4.3, Pages 12 and 13 Brief Description of Amendments The amendment request proposes to revise the ultimate heat sink inventory verification (Technical Specification 3.7.9) from a level-based to volume-based verification.

13 Proposed Determination NSHC Name of Attorney for Licensee, Mailing Address Tamra Domeyer, Associate General Counsel, Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 Docket Nos.

50-456, 50-457 NRC Project Manager, Telephone Number Joel Wiebe, 301-415-6606 Exelon Generation Company, LLC; Braidwood Station, Units 1 and 2, Will County, IL; Byron Station, Unit Nos. 1 and 2, Ogle County, IL Application Date September 24, 2019 ADAMS Accession No. ML19269C092 Location in Application of NSHC a, Section 4.3, Pages 140-142 Brief Description of Amendments The amendments would revise Braidwood Station Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for permanent extension of Type A and Type C leak rate test frequencies.

Proposed Determination NSHC Name of Attorney for Licensee, Mailing Address Tamra Domeyer, Associate General Counsel, Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 Docket Nos.

50-456, 50-457, 50-454, 50-455 NRC Project Manager, Telephone Number Joel Wiebe, 301-415-6606 Exelon Generation Company, LLC; Braidwood Station, Units 1 and 2, Will County, IL; Byron Station, Unit Nos. 1 and 2, Ogle County, IL Application Date September 30, 2019 ADAMS Accession No. ML19275E307 Location in Application of NSHC, Section 4.3, Pages 4 and 5 Brief Description of Amendments The amendment would revise Technical Specification 5.6.6 to allow use of AREVA NP Topical Report BAW-2308, Revisions 1-A and 2-A, Initial RTNDT of Linde 80 Weld Materials.

Proposed Determination NSHC Name of Attorney for Licensee, Mailing Address Tamra Domeyer, Associate General Counsel, Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 Docket Nos.

50-454, 50-455, 50-456, 50-457 NRC Project Manager, Telephone Number Joel Wiebe, 301-415-6606

14 FirstEnergy Nuclear Operating Company; Beaver Valley Power Station, Unit Nos. 1 and 2; Beaver County, PA Application Date October 20, 2019 ADAMS Accession No. ML19293A367 Location in Application of NSHC Page 26 of 28 Application Date September 11, 2019 Brief Description of Amendments The amendments would revise technical specifications regarding primary and secondary coolant activities, control room emergency ventilation system testing criteria, and permit a one-time change to the control room envelope unfiltered air inleakages test frequency.

Proposed Determination NSHC Name of Attorney for Licensee, Mailing Address David W. Jenkins, FirstEnergy Nuclear Operating Company, FirstEnergy Corporation, 76 South Main Street, Akron, OH 44308 Docket Nos.

50-334, 50-412 NRC Project Manager, Telephone Number Jennifer Tobin, 301-415-2328 Florida Power & Light Company, et al.; St. Lucie Plant, Unit No. 2; St. Lucie County, FL Application Date October 9, 2019 ADAMS Accession No. ML19282D338 Location in Application of NSHC Enclosure, Page 8 of 12 Brief Description of Amendments The amendment would modify the Unit No. 2 Technical Specifications by revising the reactor coolant pump flywheel inspection program requirements consistent with the conclusions and limitations specified in NRC safety evaluation, Acceptance for Referencing of Topical Report SIR-94-080, Relaxation of Reactor Coolant Pump Flywheel Inspection Requirements, dated May 21, 1997.

Proposed Determination NSHC Name of Attorney for Licensee, Mailing Address Debbie Hendell, Managing Attorney - Nuclear, Florida Power & Light Company, 700 Universe Blvd., MS LAW/JB, Juno Beach, FL 33408-0420 Docket Nos.

50-389 NRC Project Manager, Telephone Number Natreon Jordan, 301-415-7410 PSEG Nuclear LLC; Salem Nuclear Generating Station, Unit Nos. 1 and 2; Salem County, NJ Application Date October 23, 2019 ADAMS Accession No. ML19296B108 Location in Application of NSHC Enclosure, page 15

15 Brief Description of Amendments The amendments would address conditions of source range and intermediate range in operability that would mandate entry into Technical Specification 3.0.3.

Proposed Determination NSHC Name of Attorney for Licensee, Mailing Address Steven Fleischer, PSEG Services Corporation, 80 Park Plaza, T-5, Newark, NJ 07102 Docket Nos.

50-272, 50-311 NRC Project Manager, Telephone Number James Kim, 301-415-4125 Southern Nuclear Operating Company; Vogtle Electric Generating Plant (VEGP),

Units 3 and 4; Burke County, GA Application Date October 31, 2019 ADAMS Accession No. ML19304C381 Location in Application of NSHC, page 8 of 10 Brief Description of Amendments The amendments propose changes to the VEGP Units 3 and 4 COL Appendix C, with corresponding changes to the associated plant-specific Tier 1 information and associated Tier 2 information in the Updated Final Safety Analysis Report. Specifically, the proposed change is to update the Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) containment vessel wetted perimeter measurement to be taken at any elevation between the 266 ft.

elevation and the spring line, instead of the current requirement of taking the measurement directly at the spring line (approximate elevation of 244 ft.)

Because this proposed change requires a departure from Tier 1 information in the Westinghouse AP1000 Design Control Document (DCD), the licensee also required an exemption from the requirements of the Generic DCD Tier 1 in accordance with Section 52.63(b)(1) of 10 CFR.

Proposed Determination NSHC Name of Attorney for Licensee, Mailing Address M. Stanford Blanton, Balch & Bingham LLP, 1710 Sixth Avenue North, Birmingham, AL 35203-2015 Docket Nos.52-025, 52-026 NRC Project Manager, Telephone Number Jennivine Rankin, 415-1530 III.

Notice of Issuance of Amendments to Facility Operating Licenses and Combined Licenses

16 During the period since publication of the last biweekly notice, the Commission has issued the following amendments. The Commission has determined for each of these amendments that the application complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commissions rules and regulations. The Commission has made appropriate findings as required by the Act and the Commissions rules and regulations in 10 CFR chapter I, which are set forth in the license amendment.

A notice of consideration of issuance of amendment to facility operating license or combined license, as applicable, proposed NSHC determination, and opportunity for a hearing in connection with these actions, was published in the Federal Register as indicated.

Unless otherwise indicated, the Commission has determined that these amendments satisfy the criteria for categorical exclusion in accordance with 10 CFR 51.22. Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared for these amendments. If the Commission has prepared an environmental assessment under the special circumstances provision in 10 CFR 51.22(b) and has made a determination based on that assessment, it is so indicated.

For further details with respect to the action, see (1) the applications for amendment, (2) the amendment, and (3) the Commissions related letter, Safety Evaluation, and/or Environmental Assessment as indicated. All of these items can be accessed as described in the Obtaining Information and Submitting Comments section of this document.

Table 2 - License Amendment Issuance(s)

Duke Energy Progress, LLC; Brunswick Steam Electric Plant, Units 1 and 2; Brunswick County, NC

17 Date Issued November 21, 2019 ADAMS Accession No. ML19281A330 Amendment Nos.

296 and 324 Brief Description of Amendments The amendments modified requirements for repetitive verification of the status of locked, sealed, or secured components to allow the verification to be done by use of administrative means consistent with Technical Specification Task Force Traveler (TSTF) 269-A, Revision 2, Allow Administrative Means of Position Verification for Locked or Sealed Valves.

Docket Nos.

50-324, 50-325 Florida Power & Light Company; St. Lucie Plant, Unit Nos. 1 and 2; St. Lucie County, FL Date Issued November 20, 2019 ADAMS Accession No. ML19248C238 Amendment Nos.

201 Brief Description of Amendments The amendment revised the St. Lucie Plant, Unit No. 2, Technical Specifications by eliminating the requirements for the Iodine Removal System.

The amendment also revised the surveillance requirements for the trisodium phosphate dodecahydrate basket.

Docket Nos.

50-389 Nine Mile Point Nuclear Station and Exelon Generation Company, LLC; Nine Mile Point Nuclear Station, Unit 1; Oswego County, NY Date Issued November 25, 2019 ADAMS Accession No. ML19301B005 Amendment Nos.

239 Brief Description of Amendments The amendment revised the Nine Mile Point Nuclear Station, Unit 1, Technical Specifications to make several editorial changes (e.g.,

pagination, redundancy, number sequencing, alignment, justification, etc.)

Docket Nos.

50-220 Southern Nuclear Operating Company, Inc.; Edwin I Hatch Nuclear Plant, Units 1 and 2; Appling County, GA Date Issued November 19, 2019 ADAMS Accession No. ML19239A244 Amendment Nos.

301 and 246

18 Brief Description of Amendments The amendments revised certain technical specifications to remove the requirements for engineered safety feature systems (e.g.,

secondary containment, secondary containment valve isolation capability, and standby gas treatment system) to be operable after sufficient radioactive decay of irradiated fuel has occurred following a plant shutdown.

Docket Nos.

50-321, 50-366 Southern Nuclear Operating Company; Vogtle Electric Generating Plant (VEGP),

Units 3 and 4; Burke County, Georgia Date Issued November 21, 2019 ADAMS Accession No. ML19297C791 Amendment Nos.

168 (Unit 3) and 166 (Unit 4)

Brief Description of Amendments The amendments authorized changes to Combined License Nos. NPF-91 and NPF-92, Appendix A, which contain the plant-specific technical specifications (TSs) and related information in the Updated Final Safety Analysis Report. Specifically, the amendments removed from the TSs certain manual surveillance requirements (SRs) to be performed on Protection and Safety Monitoring System (PMS) components. These are SRs requiring manual Channel Checks, Channel Operational Tests, Actuation Logic Tests, and Actuation Logic Output Tests. In addition, the amendments authorized changes to the approach for satisfying the SRs that verify the Reactor Trip System and Engineered Safety Features Response Times are within specified limits. Specifically, the amendments approved a method described in the license amendment request for choosing allocated response times from the PMS equipment.

Docket Nos.52-025, 52-026 Tennessee Valley Authority; Sequoyah Nuclear Plant, Unit 1; Hamilton County, TN Date Issued November 21, 2019 ADAMS Accession No. ML19319C831 Amendment Nos.

348 Brief Description of Amendments The amendment revised Unit 1 Technical Specification 4.2.2, "Control Rod Assemblies," to allow Unit 1 to operate for Operating Cycle 24 with 52 full-length control rod assemblies instead of 53 full-length assemblies.

19 Docket Nos.

50-327 Tennessee Valley Authority; Watts Bar Nuclear Plant, Units 1 and 2; Rhea County, TN Date Issued November 26, 2019 ADAMS Accession No. ML19238A005 Amendment Nos.

129 (Unit 1) and 32 (Unit 2)

Brief Description of Amendments The amendments revised Technical Specification (TS) 3.8.1, "AC [Alternating Current] Sources -

Operating"; TS 3.8.7, "Inverts - Operating'; TS 3.8.8, "Inverters - Shutdown"; and TS 3.8.9, "Distribution Systems - Operating," to support performance of the 6.9 kilovolt and 480 Volt shutdown boards maintenance., The amendments revised Technical Specification (TS) 3.8.1, "AC [Alternating Current] Sources -

Operating"; TS 3.8.7, "Inverters - Operating"; TS 3.8.8, "Inverters - Shutdown"; and TS 3.8.9, "Distribution Systems - Operating," to support performance of the 6.9 kilovolt and 480 Volt shutdown boards maintenance.

Docket Nos.

50-390, 50-391 Dated at Rockville, Maryland, this 11th day of December, 2019.

For the Nuclear Regulatory Commission.

/RA/

Jamie M. Heisserer, Deputy Director, Division of Operating Reactor Licensing, Office of Nuclear Reactor Regulation.