,_

_. +

December 7, 1989

- Docket Nos. 50-369' and 50-370 MEMORANDUM FOR:- David D. Matthews, Director Project Directorate II-3 Division of Reactor Projects - I/II FROM:

Darl S. Hood, Project Manager Project Directorate 11-3 Division of Reactor Projects - I/II

SUBJECT:

FORTHCOMING MEETING-WITH DUKE POWER COMPANY REGARDING q

PRECURSORY EVENT FOR INTER-SYSTEM LOCAS, MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 DATE & TIME:

January 9, 1990 8:30 a.m. - 11:30 LOCATION:

One White Flint North Rockville, Maryland Room 12 B 11 PURPOSE:

To discuss Duke's corrective actions and plans in response to operating events at McGuire that represent precursors to an inter-system loss-of-coolant accident.

  • PARTICIPANTS:

NRC DUKE POWER COMPANY D. Matthews C. Julian H. Tucker R. Barrett T. Marsh, et al.

T. McConnell, et al.

i~

R. Jones

/s/

Darl S. Hood, Project Manager Project Directorate 11-3 Division of Reactor Projects - I/II l

l i/

l.

Enclosure:

l Agenda cc w/ enc 1:-

See next page

  • Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meeting Statement of NRC Staff Policy,"

43 Federal Register 28058,6/28/78.

OFFICIAL RECORD COPY Document Name: M RE MTG ISLOCA 1/9 gg PM:PDII3 06P PI 3

, i DHood:sa 0

thews

. /JV 7 /89 g q/89 Q9f213049699129, p

ADOCK 05000369 PDC

+ ~

7.., _

uw Duke Power Company cc:

Mr. A.V. Carr, Esq.

Dr. John M. Barry Duke Power Company Department of Environmental Health P. O. Box 33189 Mecklenburg County 422 South Church Street 1200 Blythe Boulevard Charlotte, North Carolina 28242 Charlotte, North Carolina 28203 County Manager of Mecklenburg County Mr. Dayne H. Brown,-Chief 720 East Fourth Street Radiation Protection Branch Charlotte, North Carolina 28202 Division of Facility Services Department of Human Resources 701 Barbour Drive Mr. J. S. Warren Raleigh, North Carolina 27603-2008 Duke Power Company

- Nuclear Production Department Mr. Alan R. Herdt, Chief P. O. Box 33189 Project Branch #3 Charlotte, North Carolina 28242 U.S. Nuclear Regulatory Commission 101 Marietta Street, NW, Suite 2900 J. Michael McGarry, III, Esq.

Atlanta, Georgia 30323 Bishop, Cook, Purcell and Reynolds 1400 L Street, N.W.

Ms. Karen E. Long Washington, D. C.

20005 Assister.t Attorney General K. C. Department of Justice Senior Resident Inspector P.O. Box 629 c/o U.S. Nuclear Regulatory Commission Raleigh, North Carolina 27602 Route 4, Box 529 Hunterville, North Carolina 28078 Mr. H. B. Tucker, Vice President Huclear Production Cepartment Regicnal Administrator, Region II Duke Power Company U.S. Nuclear Regulatory Commission 422 South Church Street 101 Marietta Street, N.W., Suite 2900 Charlotte, North Carolina 28242 Atlanta, Georgia 30323 Ms. S. S. Kilborn Area Manager, Mid-South Area ESSD Projects Westinghouse Electric Corporation MNC West Tower - Bay 239 P. O. Box 355 Pittsburgh, Pennsylvania 15230

to 4 ',d -

.. r.

Enclosure DUKE POWER /NRC MEETING ON INTERSYSTEM LOCA's (ISLOCA's)

JANUARY 9, 1990 NRC HEADQUARTERS - WHITE FLINT, MD AGENDA 1.

OPENING REMARKS ~

NRC REPRESENTATIVE

.j H. B. TUCKER j

2.

DESCRIPTION OF EVENTS MNS OPERATIONS REPRESENTATIVE

o. McGuire Containment Spray System Overpressurization (2NS-18A) September 5, 1989-System Design Basis

System Description

Sequence of Events / Event Description Root Cause/ Operability / Safety Significance o Other Events (Three Loss of RER Incidents: ND58; Injection Line Checkvalves, NI160) i 3.

CORRECTIVE ACTIONS MNS OPERATIONS

-l REPRESENTATIVE Training Procedures Maintenance

' Design Actions Valve Testing Study (Stroke Time Under DP) 4.

PRA ASPECTS OF ISLOCA's P. M. ABRAHAM 5.

DUKE POWER PERSPECTIVE ON T. L. McCONNELL THE SIGNIFICANCE OF ISLOCA'S Past/Present Sensitivity & Awareness Existing Procedures & Training Vulnerability During Testing Other Plants

?

Industry Sensitivity l

6.

SUMHARY STATEMENT T. L. McConnell 7.

CLOSING REMARKS H. B. TUCKER p

p l

l l L' I

p 3

*
:,j

,.!4 i

DISTRIBUTION -

genetiytip11,UIt r

NRC & Local PDRs b

PDII-3 R/F T. Murley -

12/G/18 J. Sniezek 12/G/18 J. Partlow.

12/G/18

-5. Varna 14/E/3 G. Lainas.

14/H/3

-D. Matthews 14/H/25 L

D.' Hood:

14/H/25 L

R. Ingram 14/H/25 W. Lanning 9/A/1 t

OGC 15/B/18 E.-Jordan MNBB 3302 Receptionist.

0WFN R. Barrett 10/A/2 C.'Julian RII R. Jones 8/E/23 T. Marsh 9/H/3

.ACRS(10)

P 135 GPA/PA 17/F/2 V. Wilson-12/H/5-L.-Thomas 12/E/4 R. Bordiardt 17/G/21 K. Clark A. Herdt RII

)