oenere8 offices: 212 West Michienn Avenue, Jacteen, Michleen 40201 * (517) 795 4550 August 28, 1980 Director, Nuclear Reactor Regulation Att Mr Dennis M Crutchfield, Chief Operating Reactors Branch No 5 U S Nuclear Regulatory Cc= mission Washington, D C 20555 DOCKET 50-155 - LICENSE DPR BIG ROCK POINT PLANT - CORFECTION TO TECHNICAL SPECIFICATION SUB!Ci'2AL OF DECD!BER 3,1979 - (RADI0 LOGICAL EFFLUENTS)

Attached are changes to Consumers Power Cc=pany's Dece=ber 3,1979, submittal "Respoase to Request for Added Infor=ation on Proposed Technical Specifications Changes Related to Radiological Effluents."

Table h-5 of Attach =ent 5, " Big Rock Point Plant Offsite Dose Calculation Manual November, 1979 Draft" is the incorrect Table. This Table is for ?alisades Gaseous and Particulate Design Objective Annual Quantities. Additionally, Table 2-2, Palisades Liquid Effluent Design Objective Annual Quantity was mistakenly submitted.

The correct Tables for Big Rock Point are attached.

/ if ) 'l:7 n

,A David P Hoffman Nuclear Licensing Administrator CC Director, Regien III, USNRC NRC Resident Inspectcr - Big Rock Point Attachments - 2 pages

/)oo7 s

//

800910067'/

P

~

.~ '

TABI.E h-S Gaseous and Particulate Effluents Design Objective Annual Onnntities Dose Conversion Design Ob.jective Factor Annual Quantity Nuclide Lir.iting Organ mrem / Curie C1 (Cut-les) 1-131 Thyroid 7.14hE t00 2.02E800 I.16E+02 I

I-133 Thyroid 1.29E-01 2.h9E+00 6.02E*00 Cs-134 Liver Cs-13T Liver

2. 39E+00 6.2TE*00 Co-60 G1 Tract l.51E-01 9 93E+01 3.0!E-01 k.93E+01 Mn-Sk GI Tract i

Co-58 GI Tract 2.87E-02 5.23E+02 C-ls GI Tract 6.21eE-03 2.bOE+03 i

Ba-110 Bone 2.08E-02 7.21E+02 4

Noble Gases (1 Gamma Dose in Air E

2.30E*05 1.9)iE+ 01:

NOTE:

The average garma ray energy (E) for a diffusion mixture is 0.83a5 HeV for a pure U-235 fission spectrum.

e

o__........

- ~ - -

7

.~

TABLE JE ~'.,

Liquid Effluents i

Design Objective Annual Quantity Dose Conversion Design Objective Factor Annual Quantity Nuclide limitir.g Organ (mrem / Curie)

Ci (Curies)

Cs-134 Total Body 3.62E*00 8.29E-01 Cs-13T Total Body 2.16E+03 1.39E+00 Cs-136 Total Body h.01E+00 7.h9E+00 Co-60 Total Body 2.99E-01 1.00E+01 Sr-89 Bone 1.70E-02 5.88E+02 Sr-90 Bone 1.6hE-01 6.10E+01 Fe-55 GI Tract' 1.blE-02 7.09E+02 Mn-Sh GI 7.ThE-02 1.29E+02 zn-65 GI 2.73E-01 3.66E+02

~

Cr-51 GI 1 58E-03 6.32E+03 Ba-lho GI 2.50E-03 h.01E+03 La-lho,

GI 2.20E-02 h.55E*02 i

1-121 Thyroid h.19E-01' 2.39E*01 rj.

r. w..

C0-58 GI Tract 1.13E-02 8.87E+02 H-3 Total Body 1.77E-06 1.69E*06 e

- - - - - -