05000296/LER-1980-029-03, /03L-0:on 800802,Surveillance Procedure 2.1 Performed W/Computer Valve Improperly Set Resulting in Use of Previous Day Values for Max Average Planar Linear Heat Generation Rate.Caused by Personnel Error

From kanterella
(Redirected from ML19331E212)
Jump to navigation Jump to search
/03L-0:on 800802,Surveillance Procedure 2.1 Performed W/Computer Valve Improperly Set Resulting in Use of Previous Day Values for Max Average Planar Linear Heat Generation Rate.Caused by Personnel Error
ML19331E212
Person / Time
Site: Browns Ferry 
Issue date: 09/04/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19331E210 List:
References
LER-80-029-03L-02, LER-80-29-3L-2, NUDOCS 8009090328
Download: ML19331E212 (2)


LER-1980-029, /03L-0:on 800802,Surveillance Procedure 2.1 Performed W/Computer Valve Improperly Set Resulting in Use of Previous Day Values for Max Average Planar Linear Heat Generation Rate.Caused by Personnel Error
Event date:
Report date:
2961980029R03 - NRC Website

text

-.

a NRC F OXPA 34 6 Da S. NUCLE AA HEGULAveWV CWMIS$40A LICENhte EVENT REP' ccNtRoL nLocx: l l

l l

l l }@

~

(PtEAsE PRINT OR TYPE ALL REQUIRED INFORMATION)

S TlAlLlBlRlFl1 !@l0 l0 l-lo l0 l0 l0 10 l - l 0 l 0 l@64l1l1l1l1l@l l

l@

1 1 9 UCENSEE COOg to 15 uCEN5E NLMcER 2S 2

uCENSE TYPE JO 57 C A I Se CON ^f 1011]

'1*,,"' l L @l 0 l 5 l0 l0 l0 ~ l2 l 9 l6 @l 01810 l 2 l 8 l 0 @lo 19 lo la la lo l@

I 88 60 61 QQCK ET NbMSER ee 69 Eb ENT DATE 74 rs REPORT OATE

'O I: VENT DESCRIPTION AND PRCBA8tE CONSEOUENCES h 10 6 :1 l During preconditioning, Surveillance Instruction 2.1 was performed with the computer g l terninal value improperly set.

This resulted in computer using previous day's value Q W jfor its MALPHCR limits. The previous day's value was more limiting than the present I

] o l $. I gonditions; thus no limits were exceeded. No previous occurrences. No danger or l o lQ lhazard to public resulted.

(Tech Spec 3.5.I) 101 i L lold L__

F es 1

.v5T E M CASE

CAUSE

i Of**P VALvt CODE COpC SU8C00f C O*.tPONENT CODE sosec37 S'MCOCE 1o19 I Z l ZI@ W@ l A l@ I z l z l z l z i z lz l@ l zi@ LZJ @

i as 3

to it 12 12 in N

20 S E Ou t Nt ia c oCCLRRIeCE REPORT

=E.

9 *4

@.g, I gg a n EVENTvEAR 54 EPORT NC CODE Tvrt

  • es I810I l-l Iol2I9I lf_)

10 13 l W

I-1 Loj

_2 u

n 4

6 2r 2.

n

.o 2

NION CN PL NT MET HOURS 22

$ 3 i POR h6

$ PPI.

VANt C*LRE-TA LJJ@LZJ@

LZJ@

EJ@

lolololol lY_Jg lN l@

y@

l z l9 19 l9,

.13

,a4 3$

36 37 40 el 47 43 44 CAUSE DESCRIPTION ANO CORRECTIVE ACTIONS @

l : 1 ] l Personnel error resulted in improper process computer values.

Surveillance Instruction gj l 2.1 has been revised to require STA signoff for complete and valid PI and OD6-4.

li l el I ii i il I LLLJ l 7

8 9 ST i Js

% POWER OTHER ST A TUS e5 Ov RY DISCOVERY CESCRIPTION f M d h l0l7l7lgl NA j

l B gl Engineer SI review A it.]f y CON ? t m.T ntLte ?.ED OF n#LE ASE AVOLNT GF ACTavtTV LCCAT ON O8 RELEASE f TR L l@ LzJ@l

"^

l I

  • ^

S 3

10 31 44 AS

    • 't%ONNt L F W PCSUR E5 49 tMitg ra TVPE l i I J l ol o! nJ@l z l@O($thlPTION -

n Pc.S.Nd',N,u',',Es otscRiPooNh-woma I T] I ol el ol@l NA

  • d 1 11 12 L ES Or oft 01 MAGE TO F AcellTV T t f UESCRIPTION FW1 L7J@l NA c

r 4 9 to Putit tCli v NRCUSEGtpY i

.121 R. U@OsSCRIPTION' NA l.llIIllI'IIl f

W,t ;n l

- g 3

Y

.68 69 8009090 NAME OF PREPARER PHON E:

)

O i

Tennessee Valley Authority Form BF-17 Brownr. Ferry Nuclear Plant BF 15.2 1/10/79 LER SUPPLEMENTAL INFORMATION BFRO 296 /_ 8029 Technical Specification Involved 3.5.I Reported Under Technical Specification 6.7.2.b(3)

Date of Occurrence 8/2/80 Time of Occurrence 1426 Unit 3

!_dentification and Description of' Occurrence:

~

During performance of SI 2.1, the value wheel was not set at 0 on process computer terminal as specified by SI; when OD6-4 was demanded for MAPLHGR calculation the wrong value was computed. A lower limit was used in computer carried over from previous day, thus, thermal limits were not exceeded.

_Cor.ditions ~ Prior to Occurrence:

Unit 1 0 98%

Unit 2 @ 61%

Unit 3 0 77%

Action specified in the Technical Specification Surveillance Requirements a:".

dua to inoperable equipment.

Describe.

NA Apparent Cause of Occurrence:

Personnel f ailed to set value wheel to 0 for OD 6-4.

Analysis of Occurrence:

There was no damage to plant equipment. There was no activity release, no personnel exposure or injury and no danger to the he,alth or safety of the public.

Corrective Action

ST Z 1 nas oeen Esvised to include a signoff by the STA verifying that the attached PI and OD 6-4 are complete and valid.

F_aqure Data:

None

  • Retention :

eriod - Lifetime; Responsibility - Administrative Supervisor

  • Revision:

_Go