O TABLE 2.2-1 (Continued) e C
Q REACTOR TRIP SYSTEM INSTRUMENTATION TRIP SETPOINTS m
4 9
FUNCTIONAL UNIT TRIP SETPOINT ALLOWABLE VALUES f
- 13. Steam. Generator Water 2,12% of narrow range instrument 111%of narrow range instrument g
Level--Low-Low span-each steam generator span-each steam generator
[
- 14. Steam'/Feedwater Flow
< 40% of full steam flow at
< 42.5% of full steam flow at 5
Mismatch and Low Steam BTED THERMAL POWER coincident RATED THERMAL POWER coincid,ent H
Generator Water Level with steam generator water level with steam generator water level
> 25% of narrow range instru-
> 24% of narrow range instru-
~
ment span--each steam generator ment span--each steam gensrator
- 15. Undervol tage-Reactor
> 2750 voits-each bus
> 2725 volts-each bus g
Coolant Pumps tn E
- 16. Underfrequency-Reactor
> 57.5 Hz - each bus
> 57.4 Hz - each bus E
y Coolant Pumps 8
~
g
- 17. Turbine Trip A.
Auto stop oil Pressure 45 psig
+ 5 psig g
B.
Turbine Stop Valve
> 1% open
> 1% open
- 18. Safety Injection Input Not Applicable Not Applicable from ESF
- 19. Reactor Coolant Pump Not Applicable Not Applicable Breaker Position Trip i
i e