Other: 05000280/LER-1980-046, Forwards LER 80-046/03L-0, A01085, Forwards Nonproprietary Response to Questions on Cycle 4 Basic Safety Rept, A01151, Advises of Minor Adjustments to Evaluation Program Re Resolution of Cycle 3 Startup Commitments.Adjustments Are to Optimize Timetable for Critical Path Refueling Activities, B10005, Discusses Small Break LOCA ECCS Performance Results. Primarily Effect Function of Sys Characteristics Such as ECCS Flow Rates,Safety Injection Tank Actuation Pressures & Core Power Level.Supporting Info Encl, B10009, Forwards Reload Safety Analysis, Demonstrating That Cycle 4 Reload Assures Continued Conformance to Design & Safety Limits of Facility, B10015, Forwards Large Break Loca/Eccs Performance Results. Analysis Showed double-ended Cold Leg Guillotine Break at Pump Discharge to Be Limiting Large Break.Review of Results Determined That Applicable Fee Was Submitted 800509, B10028, Forwards Addl Info Re Fuel Design & Physics Calculations Per RA Clark 800620 Request.Response to Question 10 Withheld (Ref 10CFR2.790), B10060, Forwards Addl Info Requested by NRC Re Design Mod to Cycle 4 Fuel Assemblies & QA Program in Effect During Design of Cycle 4 Reload Fuel, B10068, Advises That C-E Owners Group 800215,0630 & 0731 Ltrs Re Asymmetric LOCA Loads Are Applicable to Millstone Unit 2 & Should Be Regarded as Util Response to NRC 780125 Request, B10076, Forwards Nonproprietary & Proprietary Repts, Guide Thimble Inset Design. Withholding Application & Affidavit Encl. Proprietary Version Withheld (Ref 10CFR2.790), B10080, Corrects Typographical Error in Tech Spec Table 3.9-1 of Amend 60 to License DPR-65.Doors 292 & 297,listed as Servicing Solidification Sys Area,Should Be 292 & 207, B10084, Submits Addl Info Re Fuel Misload Analysis Performed in Support of Cycle 4 Reload.Procedures Utilized During Fuel Movement Provide Adequate Assurance That Probability of Fuel Misloading Event Is Sufficiently Low to Preclude Analysis, ML19210C634, ML19210C638, ML19253B386, ML19257A505, ML19296B295, ML19296B298, ML19305E096, ML19309B532, ML19309C217, ML19309G003, ML19312E209, ML19312E212, ML19318A345, ML19323C588, ML19323C595, ML19323D864, ML19323H680, ML19330B446, ML19332A343, ML19337A776, ML19338C766, ML19338E936, ML19344D183, ML20076A987, ML20125A706
|
MONTHYEARML19256A1121978-10-27027 October 1978 Application for Amend to License DPR-35,changing Tech Specs to Accomodate New Steamline Break Protection Sys Scheduled for Installation in Spring of 1979.Fee Paid Project stage: Request ML20037A2061979-03-21021 March 1979 Forwards Proprietary Info Presented to NRC at 790126 Meeting Re Reload Application.Info Withheld (Ref 10CFR2.790) Project stage: Meeting ML20076A9871979-04-27027 April 1979 Forwards Proposed Revision to Tech Specs to Allow Unlimited Containment Purges.Revisions Deal W/Containment Isolation Valves Project stage: Other ML19274G1021979-07-31031 July 1979 Forwards Request for Addl Info to Util Proposed Steam Break Protection Sys & N-1 Loop Operation Project stage: RAI ML19207B9461979-08-28028 August 1979 Forwards Addl Info Supporting Tech Specs Change 35 Re Proposed New Steamline Break Protection Sys,In Response to 790731 Request Project stage: Other ML20125A7061979-08-31031 August 1979 Proposed Revisions to Tech Specs to Add Leak Rate Surveillance Requirements to ECCS & Containment Sys Project stage: Other ML19253B3861979-10-0909 October 1979 Discusses Method for Mitigating Control Element Assembly Guide Tube Wear in Fuel Supplied by Westinghouse for Cycle 4.Util Will Use Westinghouse Sleeve Design Project stage: Other ML19210C6341979-11-0909 November 1979 Responds to Re Resolution of Cycle 3 Startup Commitments.Forwards Rept, Evaluation of Neutron Shield Effectiveness Project stage: Other ML19210C6381979-11-30030 November 1979 Evaluation of Neutron Shield Effectiveness Project stage: Other ML19257A5051979-12-31031 December 1979 Responds to NRC 790913 TMI Lessons Learned Task Force short- Term Requirements.All short-term Requirements Will Be Implemented by 800101.Implementation Rept Encl Project stage: Other ML19296B2951980-02-0808 February 1980 Discusses Fuel Cladding Strain & Fuel Assembly Flow Blockage Models for Facility.Analysis Was Performed for Operating Plants W/Ce Fuel.Forwards Analysis Verifying Compliance W/Eccs Acceptance Criteria Project stage: Other ML19296B2981980-02-29029 February 1980 Verification of Compliance W/Eccs Acceptance Criteria of Code Utilizing Conservative Cladding Rupture Strain & Assembly Flow Blockage Models Project stage: Other ML19344D1831980-02-29029 February 1980 Discusses Slightly Diminished Capacity of Charging Pumps to Inject Concentrated Boric Acid Into RCS Under Test Conditions.Change in Peak Clad Temp Due to Smaller Charging Pump Flow Is Not Significant Enough to Be Reportable Project stage: Other ML19290E3391980-03-0606 March 1980 Forwards Basic Safety Rept, in Support of Cycle 4 Reload. Affidavit Encl.Rept Withheld (Ref 10CFR2.790) & Available in Central Files Only Project stage: Other ML19309B5321980-03-26026 March 1980 Forwards Basic Safety Rept. Proprietary Version Withheld (Ref 10CFR2.790).Affidavit Previously Submitted on 800229 & 760727 Project stage: Other ML19309C2171980-03-31031 March 1980 Outlines Plans for Cycle 4 Reload Outage Steam Generator Insp Per Amend 52 to License DPR-65.Resolution of Cycle 3 Startup Commitments Encl Project stage: Other ML19305E0961980-04-15015 April 1980 Submits Info in Support of Continued Operation W/Sleeved Guide Tubes in Cycle 4.Anticipates That Negligible Guide Tube Sleeve Wear Will Be Measured Project stage: Other ML19309G0031980-04-24024 April 1980 Responds to IE Bulletin 79-13, Cracking in Feedwater Sys Piping. Util Conducted Insp During Aug 1979 Outage.Several Crack Indications in nozzle-to-pipe Welds of Both Steam Generators Were Found.All Repairs Completed Project stage: Other ML19323C5881980-05-0707 May 1980 Forwards Revised Steam Generator Insp. Includes Final Dent Progression Statistics Re Mar 1979 Steam Generator Tube eddy-current Insp.Biases Identified in Testing Procedures Have Been Corrected Project stage: Other ML19323D8641980-05-13013 May 1980 Submits Info Re Proposal for Permanent Type Repair of Containment Electrical Penetrations.Penetration Modules Which Have Experienced Insulation Resistance Degradation, Will Be Replaced Project stage: Other B10002, Forwards Proprietary Version of Basic Safety Rept Addendum, Nuclear Uncertainties, Supplementing Rept Section 4.0. Describes Power Peaking Factor Uncertainty Analysis Used in Reload Fuel Design.Rept Withheld (Ref 10CFR2.790)1980-05-28028 May 1980 Forwards Proprietary Version of Basic Safety Rept Addendum, Nuclear Uncertainties, Supplementing Rept Section 4.0. Describes Power Peaking Factor Uncertainty Analysis Used in Reload Fuel Design.Rept Withheld (Ref 10CFR2.790) Project stage: Supplement ML19312E2091980-05-30030 May 1980 Forwards Addendum to Basic Safety Rept Re Nuclear Uncertainties,Nonproprietary Version Project stage: Other ML19323C5951980-05-31031 May 1980 Steam Generator Insp Project stage: Other ML19312E2121980-05-31031 May 1980 Addendum to Basic Safety Rept Re Nuclear Uncertainties, Nonproprietary Version Project stage: Other B10005, Discusses Small Break LOCA ECCS Performance Results. Primarily Effect Function of Sys Characteristics Such as ECCS Flow Rates,Safety Injection Tank Actuation Pressures & Core Power Level.Supporting Info Encl1980-06-0202 June 1980 Discusses Small Break LOCA ECCS Performance Results. Primarily Effect Function of Sys Characteristics Such as ECCS Flow Rates,Safety Injection Tank Actuation Pressures & Core Power Level.Supporting Info Encl Project stage: Other B10009, Forwards Reload Safety Analysis, Demonstrating That Cycle 4 Reload Assures Continued Conformance to Design & Safety Limits of Facility1980-06-0303 June 1980 Forwards Reload Safety Analysis, Demonstrating That Cycle 4 Reload Assures Continued Conformance to Design & Safety Limits of Facility Project stage: Other B10015, Forwards Large Break Loca/Eccs Performance Results. Analysis Showed double-ended Cold Leg Guillotine Break at Pump Discharge to Be Limiting Large Break.Review of Results Determined That Applicable Fee Was Submitted 8005091980-06-11011 June 1980 Forwards Large Break Loca/Eccs Performance Results. Analysis Showed double-ended Cold Leg Guillotine Break at Pump Discharge to Be Limiting Large Break.Review of Results Determined That Applicable Fee Was Submitted 800509 Project stage: Other ML19329G1251980-06-16016 June 1980 Summary of 800604 Meeting W/Util in Bethesda,Md Re Cycle 4 Reload at Facility W/Westinghouse Fuel.List of Attendees & Agenda Encl Project stage: Meeting ML20244B0591980-06-16016 June 1980 Summary of 800604 Meeting W/Util in Bethesda,Md Re Cycle 4 Reload at Facility W/Westinghouse Fuel.List of Attendees & Agenda Encl Project stage: Meeting ML19310A8971980-06-18018 June 1980 Summary of 800318 Meeting W/Util & Westinghouse Re Cycle 4 Reload W/Westinghouse Fuel Project stage: Meeting ML19326D8271980-06-20020 June 1980 Requests Response to Encl Questions Re Fuel Design & Physics Calculations to Complete Review of Basic Safety Rept Supporting Cycle 4 Reload.Requests That Addl Info Be Provided by 800630 to Meet Review Schedule Project stage: Approval ML19318A3451980-06-30030 June 1980 Large Break Loca/Eccs Performance Results Project stage: Other ML19323H6801980-06-30030 June 1980 Reload Safety Analysis Project stage: Other B10028, Forwards Addl Info Re Fuel Design & Physics Calculations Per RA Clark 800620 Request.Response to Question 10 Withheld (Ref 10CFR2.790)1980-07-0707 July 1980 Forwards Addl Info Re Fuel Design & Physics Calculations Per RA Clark 800620 Request.Response to Question 10 Withheld (Ref 10CFR2.790) Project stage: Other ML19330B4461980-07-22022 July 1980 Forwards Addl Response to Questions on Cycle 4 Basic Safety Rept,In Response to .Info in 800707 Submittal Is Not Proprietary to Westinghouse or C-E Project stage: Other ML19332A3431980-08-0606 August 1980 Forwards Addl Info Requests Re Thermal Hydraulics & Accident & Transient Analysis Sections of Basic Safety Rept, & Cycle 4 Reload Safety Analysis.Requests Addl Info,Requested on 800710,18 & 29,by 800815 to Meet Review Schedule Project stage: Other A01151, Advises of Minor Adjustments to Evaluation Program Re Resolution of Cycle 3 Startup Commitments.Adjustments Are to Optimize Timetable for Critical Path Refueling Activities1980-08-14014 August 1980 Advises of Minor Adjustments to Evaluation Program Re Resolution of Cycle 3 Startup Commitments.Adjustments Are to Optimize Timetable for Critical Path Refueling Activities Project stage: Other A01085, Forwards Nonproprietary Response to Questions on Cycle 4 Basic Safety Rept1980-08-14014 August 1980 Forwards Nonproprietary Response to Questions on Cycle 4 Basic Safety Rept Project stage: Other B10060, Forwards Addl Info Requested by NRC Re Design Mod to Cycle 4 Fuel Assemblies & QA Program in Effect During Design of Cycle 4 Reload Fuel1980-08-27027 August 1980 Forwards Addl Info Requested by NRC Re Design Mod to Cycle 4 Fuel Assemblies & QA Program in Effect During Design of Cycle 4 Reload Fuel Project stage: Other B10061, Application for Amend to License DPR-65,incorporating Proposed Revisions to Tech Specs Required to Support Plant Operation During Cycle 4 Reload1980-08-29029 August 1980 Application for Amend to License DPR-65,incorporating Proposed Revisions to Tech Specs Required to Support Plant Operation During Cycle 4 Reload Project stage: Request ML19338C7661980-08-29029 August 1980 Proposed Revisions to Tech Specs Required to Support Plant Operation During Cycle 4 Reload Project stage: Other 05000280/LER-1980-046, Forwards LER 80-046/03L-01980-09-0808 September 1980 Forwards LER 80-046/03L-0 Project stage: Other B10068, Advises That C-E Owners Group 800215,0630 & 0731 Ltrs Re Asymmetric LOCA Loads Are Applicable to Millstone Unit 2 & Should Be Regarded as Util Response to NRC 780125 Request1980-09-10010 September 1980 Advises That C-E Owners Group 800215,0630 & 0731 Ltrs Re Asymmetric LOCA Loads Are Applicable to Millstone Unit 2 & Should Be Regarded as Util Response to NRC 780125 Request Project stage: Other ML19338E7681980-09-10010 September 1980 Informs That Review of Responses Re ECCS Evaluation Models Dealing W/Fuel Cladding Swelling & Incidence of Rupture Has Been Completed.Response Acceptable Project stage: Approval B10076, Forwards Nonproprietary & Proprietary Repts, Guide Thimble Inset Design. Withholding Application & Affidavit Encl. Proprietary Version Withheld (Ref 10CFR2.790)1980-09-18018 September 1980 Forwards Nonproprietary & Proprietary Repts, Guide Thimble Inset Design. Withholding Application & Affidavit Encl. Proprietary Version Withheld (Ref 10CFR2.790) Project stage: Other B10080, Corrects Typographical Error in Tech Spec Table 3.9-1 of Amend 60 to License DPR-65.Doors 292 & 297,listed as Servicing Solidification Sys Area,Should Be 292 & 2071980-09-22022 September 1980 Corrects Typographical Error in Tech Spec Table 3.9-1 of Amend 60 to License DPR-65.Doors 292 & 297,listed as Servicing Solidification Sys Area,Should Be 292 & 207 Project stage: Other B10084, Submits Addl Info Re Fuel Misload Analysis Performed in Support of Cycle 4 Reload.Procedures Utilized During Fuel Movement Provide Adequate Assurance That Probability of Fuel Misloading Event Is Sufficiently Low to Preclude Analysis1980-09-26026 September 1980 Submits Addl Info Re Fuel Misload Analysis Performed in Support of Cycle 4 Reload.Procedures Utilized During Fuel Movement Provide Adequate Assurance That Probability of Fuel Misloading Event Is Sufficiently Low to Preclude Analysis Project stage: Other B10092, Application to Amend License DPR-65 Authorizing Performance of Tests at Reduced RCS Inlet Temps in Order to Quantify Secondary Plant Performance Losses1980-09-30030 September 1980 Application to Amend License DPR-65 Authorizing Performance of Tests at Reduced RCS Inlet Temps in Order to Quantify Secondary Plant Performance Losses Project stage: Request ML19337A7761980-09-30030 September 1980 Guide Thimble Inset Design, Nonproprietary Version Project stage: Other ML19338E9361980-09-30030 September 1980 Proposed Revision to Tech Specs 3/4 2-3 for Amend 55 to License DPR-65.Authorizes Performance of Tests at Reduced RCS Inlet Temps in Order to Quantify Secondary Plant Performance Losses.Low Temp Testing Safety Review Encl Project stage: Other 1980-05-31
[Table View] |
Text
+*f%'o,$
\\
UNITED STATES
\\
[
v.
NUCLEAR REGULATORY COMMISSION r.
ay WASHINGTO N, D. C. 20555
'% * * < < < /
June 20,1980 Docket No. 50-336 Mr. W. G. Counsil, Vice President
~
Nuclear Engineeri.ng & Operations
~
Northeast Nuclear Energy Company P. O. Box 270 Hartford, Connecticut 06101
Dear Mr. Counsil:
In the process of reviewing the Basic Safety Report supporting the Cycle 4 I
Reload of Millstone, Unit No. 2, we find that additional information as delaited in the enclosure is needed to complete our review.
These questions relate to fuel design and physics calculations. Other questions may arise from reviews under way.by the Thermal-Hydraulic Sections of che Core Per-formance Branch and by-the Reactor Systems Branch.
In order to meet the agreed upon schedule for this review, please provide the additional information, previously telecopied to Mr. R. Kacich on June 16,1980, by June 30, 1980.
Sincerely, r
lim Robert A. Clark, Chief Operating Reactors Branch #3 Division of Licensing
Enclosure:
Request for Additional Information cc w/ enclosure: See next page s
f
~
l Northeast Nuclear Energy Ccmpany Mr. John Shedlosky cc:
William H. Cuddy, Esquire Resident Inspect,or/ Millstone Day, Berry & Howard c/o U.S. NRC Counselors at Law P. O. Drawer KK One Constitution Plaza Niantic, CT 06357 Hartford, Connecticut 06103 Mr. Charles B. Brinkman Anthony Z. Roisman Manager - Washing, ton Nuclear i
Natural Resources Defense Council Operations 917 15th Street, N.W.
C-E Power Systems Washington, D.C.
20005 Combustion Engineering, Inc.
4853 Cordell Ave., Suite A-1 Mr. Lawrence Bettencourt. First Selectman Bethesda, Maryland 20014~
Town of Waterford Hall of Records - 200 Boston Post Road Waterford, Connecticut 06385 Northeast Nuclear Energy Company ATTN:
Superintendent Millstone Plant Connecticut Energy Agency Post Office Box 128 ATTN: Assistant Director, Research Waterford, Connecticut 06385 and Policy Development Department of Planning and Ener97 Director, Technical Assessment Policy Division 20 Grand Street Office of Radiaticn Programs Hartford, Connecticut 06106 (AW-459)
U. S.* Environmental Protection Agency Crystal Mall #2 Arlington, Virginia 20460 U. S. Environmental Protection Agency Region I Office ATTN: EIS COORDINATOR John F. Kennedy Federal Building j
Boston, Massachusetts 02203 Waterford Public Library Rope Ferry Road, Route 156 Waterford, Connecticut 06385 Northeast Utilities Service Company ATTN: Mr. James R. Himmelwright Nuclear Engineering and Operations P. O. Box 270 Hartford, C.nnecticut 06101 o
~
1
~
n
.4
ENCLOSURE Questions on Westinghouse Basic Sa'fety Report for Millstone,' Unit'2 l
l.
Coolant pressure drop calculations for the Westinghouse fuel assembly design indicates a matching of the overall pressure drop with that for the original Combustion Engineering Millstone 2 fuel assembly design. However, at each axial elevation the pressure drops do not match up between the Westinghouse and Combustion Engineering fuel designs. The largest variation in pressure drops for the two designs occurt at the lower nozzle where the Westinghouse design has a higher pressure-loss coef ficient. This variation in pressure drop will result in an inlet flow maldistribution with less direct flow through the Westinghouse bottom nozzle. The BSR should provide justification as to why the resulting cross flow downstream of the bottom nozzle will not produce an unacceptable degree of fretting wear at sites where spacer grid springs and dimples contact fuel rods.
2.
The Westinghouse fuel assembly design has 4 holddown springs, while the original Combustion Engineering design has 5 springs.
Discuss the differences in the static and dynamic response of each fuel assembly design. The raised pad on the center of the top nozzle orifice place prevents the Westinghouse holddown springs from being compressed solid.
Does this pad limit the axial distance that the Westjnghouse fuel assemblies can grow relative to that of the original Combustion Engineering fuel assemblies? Will the spacer grids of the two fuel assembly. designs always line up? What is the safety signifi-cance if grid-to-grid alignment cannot be assured (i.e., will there be neutronic anomalies, will assembly peripheral fuel rods be punctured)?
3.
The BSR states that cladding flattening is precluded during the projected exposure of the fuel.
Provide,the minimum time to collapse as calculated with the COLLAP code. What is the design maximum value of fuel assembly burnup?
4, What is the calculated minimum shoulder gap which allows for differential growth between fuel rods and the fuel assembly? Provide the two Zircaloy growth correlations used in this calculation and describe or provide the' data base from which these correlations were determined.
How were the growth correlations combined with (a) fabrication tolerances, (b) differential thermal strains of the fuel assembly and reactor in-ternals, and (c) elastic compression and creep of the guide thimble tubes? For steady-state operation, at what axially-averaged assembly burnup will interference result in rod bow?
4 w
5.
The NRC staff has not commenced the review of the Westinghpuse generic topical report WCAP-8691, Revision 1, " Fuel Rod Bowing Evaluation,"
which is referenced in the BSR.
Specifically, the BSR uses a formula from WCAP-8691 that projects anticipated rod bow magnitudes due solely to geometrical changes in the fuel rod thickness and diameter and spacer grid span length. This formula has been somewhat controversial-and has not been accepted by the staff. Therefore, we will require that the degree of rod bowing in the Westinghouse reload fuel be calculated with the existing approved method, which is~ relatively more conservative.
In spite of this additional conservatism, however, we do not calculate a need for. a DNBR penalty until an assembly burnup of 36,300 MWD /tU is attained at which exposure the 50% gap closure value is reached.
We require that Westinohouse confirm our calcula-
~
tions and verify that no other changes in fuel design variables (i.e.,
grid spring preload, degree of cladding cold work, etc.) are significant to the rod bowing extrapolation for the Millstone, Unit 2 reload fuel.
6.
The Combustion Engineering supplied fuel for Millstone, Unit 2 was designed according to a specific set of Specified Acceptable Fuel Design Limits (SAFDLs).
Please list all of the Westinghouse SAFDLs for the Millstone reload fuel and provide the bases for omissions or additions to the original Combustion Engineering set of SAFDLs.
7.
Some of the accident analyses described in the BSR were performed with the computer codes FACTRAN (WCAP-7908, "FACTRAN, A Fortran IV Code for Thermal Transients in a U0p Fuel Rod) and LOFTRAN (WCAP-7907, "LOFTRAN Code Description").
Our review of these topicals has pro-gressed to the point that there is reasonable assurance that the con-clusicns based on these analyses will not be appreciably altered by completion of the analytical review, and therefore that there will be no effect on the decision to issue a license amendment.
If the final approval of these topical reports indicates that any revisions to the analyses are required, Millstone Unit 2 will be required to implement the results of such changes.
8.
Please either reference or provide a thorough description of the Westinghouse Computer Analysis Code (WECAN), which was used to perform the stress analyses of fuel assembly components.
9.
Comparisons of power peaking in fuel pins adjacent to CEA water holes using TURTLE (diffusion theory) and KEN 0 (Monte Carlo) have shown an ur.derprediction by diffusion theory, as expected.
Please provide additional information, such as comparisons between KENO calculations and experimental measurements of water hole power peaking, to justify the KEN 0 calculational uncertainty used.
s a
'l 0.
The fuel rod support grid for Cycle 4 will be Inconel-718 rather than Zircaloy-4 as used in Cycle 3.
What are the effects of this material change on power distributions and other physics. parameters?
11.
Power. distributions calculated by TURTLE appear to underpredict the power in the peripheral assemblies while overpredicting the power in the center assemblies.
In view of the large errors in predicting CEA worth near the core periphery due to these power distribution inaccur-
- acies', justify the use of TURTLE without some type of baffle correction scheme.
- 12. The CEA drop analysis was performed without automatic rod control (CEA motion inhibit) or turbine load reduction.
Is thi.s.the operati.onal plan for Cycle 47 13.
The parameters used in the analysis of the CEA ejection accident appear to be representative of Westinghouse cores and differ from the previous Millstone, Unit 2..fueLsupplier in several areas such as ejected rod worths, ejection time,(del.ayed neutron, fraction, feedback reactivity weighting, and power peaking F).
Please provide a comparison between the-Cycle 3
~
q and Cycle 4 values of these rod ejection initial assumptions and discuss the reasons for and effects of any differences.
a k
-.,.. ~,., - - -,. - -
r--