Forwards Review of Operating Procedures,Associated Operating Instructions & Operations Surveillance Test Procedures Prior to Startup
ML19325F318
Person / Time
Site: Calvert Cliffs  
Issue date: 11/10/1989
From: Creel G
BALTIMORE GAS & ELECTRIC CO.
To: Kane W
NRC
References
NUDOCS 8911200119
Download: ML19325F318 (8)


Text

-

h5,. 9 '

I DALT'M O RE OAS AND ELECTRl(

CHARLES CENTER. P. O. BOX 1476. BALTIMORE, MARYLAND 2i203 Gromot C. Catti v.ca Pas sio =v Nucatan t,esper

(* on no-a * *

  • November 10,1989 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Mr. W. F. Kane

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit Nos.1 & 2; Docket Nos. 50-317 & $0.318 Review of Operations Procederes

REFERENCE:

(a) Telephone Conversation between Mr.

J.

T.

Wiggins (NRC) and Mr. G. C. Crtel (BG&E), November 3,1939, same subject Gentlemen:

During discussions between NRC and BG&E staff, we described our initiative to review Operating Procedures and associated Operating Instructions, as well as selected Operations Surveillance Test Procedures prios to the Unit One startup. As requested in Reference (a), the procedures being reviewed and our schedule for completion of these reviews is provided in Enclosure (1).

Should you have any further questions regarding this matter, we will be pleased to discuss' them with you.

Very truly yours,

)

/

GCC/LSL/dtm Enclosure w\\

cc:

D. A. Brune, Esquire g

J. E.

Silberg, Esquire A

p

,y. g,cQ' p \\

R. A.Capra, NRC J. T. Wiggins, NRC g

A. R. Blough, NRC J

S. A.McNeil, NRC bglbgO 0{

f D W. T. Russell, NRC 0

J. E. Beall, NRC q

T. Magette, DNR l

fyl 8911200119 891110

- PDR ADOCK 05000317

_-___M____

(PCG)

l m

(

ENCLOSURE fl)

CALVERT CLif FS' REVIEW OF OPERATING PROCEDURES l

1 j

In preparation for start-up of Unit One, Calver t Cliffs is reviewing Operating Procedures (OP),

associated Operating instructions (01),

as well as selected Operations Surveillance Test Procedures (STP). The list of the procedures being review-d i* provided in Tables (1) through (3). Our process includes a review of each of these procedures by members of the operations staff, validation of ops on the simulator, and incorporation of recommended changes.

Operating Procedure /Opeiating Instruction reviews are progressing on a schedule which should have the expected OP/OI changes required prior to start-up identified

- for training by November 24, 1989. This will allow training (on 6he expected procedure changes) for the five contiot room crews to begin during the week of November 27, 1989.

Add!t.i nal training shall consist of a review of the selected OP retrain tasks ideatified in the Calvert Cliffs Nuclear it,wer Plant Job / Task Analysis. A combination of classroom training, simulator training, and required reading shall be used to present the material. As a minirium, any control room crew members who are absent from the training will review the ops and their changes through the required reading process.

One control room crew will be traiaed each week. Therefore, each crew will be trained on the OP/OI changes associated with our reviews prior to the scheduled start-up date of Unit One.

All STPs should be reviewed and changes incorperated by December 8,

1939. Our schedule for incorporating any required changes

  • o each OP and associated Ols is shown below. As the procedures receive Plant Operations and Safety Review Committee approval, any differences between the expecied changes provided to Nuclear Training and the approved procedures will be nssessed and appropriate additional training provided.

ECD for Incorporating Required Changes Operatine procedure to each OP and Associa,lrst Ols OP- ?

December 6,1989 OP-2 December 1,1989 OP-3 Nosember 22,1989 OP-4 November 22,1989 OP-5 December 13,1989 l

l l

l l

l

.z-t'

o. -

TABLE (1)

PRE-STARTUP OPERATIONS PROCEDURE REVIEW PROCEDURE ASSOCIATED REVIEW COIFLETE HRY REqulRE CHlWIGES OWWIGES NulBER OP (YES/ND)

PRIOR TO S/U(YES/IB)

IIICORPWATED OI-11A 1,3,5 YES NO N/R OI-118 YES NO N/R OI-11C YES NO N/R 0I-110 5

YES NO N/R 01-12A 1,2,S,5 YES YES 01-13 1,2,5 YES YES01-17E YES YES 0I-30 2,4,5 YES YES 01-32 1,2,4 YES YCL 01-42 2,3,4 YES YES01-43A 2,4 YES YES01-43C 2,3 YES YES L

OP-1 YES YES OP-2 YES YES OP-3 No OP-4 YES YES OP-5 NO N/R NOT REQUIRED

~

4-(rjw e, c.

)E

.p ;.

g

's l'

,s t,',

a l

M i{'

\\

i I

1 O

i I

1 ce m

a m

m m

N W

N W

W W

=

a i

i

~

i l

=

m m

m m

m m

m m

m m

m m

W W

W W

W W

W W

W W

W W

E '

W-E i

k,

_S I

B e

wg r

-E EE WG i

m m

m m

m m

m m

m m

m m

m m

m W

W W

W W

o W

W W

W o

W W

W W

W W

W

    • u

>=

>=

2

>=

>=

>=

2

>=

>=

>=

>=

>=

5 5,

4 Q

{

b f

e.

l 8

m.

m.

m.

m.

m.

m.

m.

e.

m.

r.a: g m

N N

N o

Di W

G o

t er W

r ce

>==c

<c co u

o W

z aC cc y

o W

O aC CO U

a et o

o o

o o

N N

N N

N M

W CO CO CO CO Ch a-*

e-*

CE t

aiaa i

ai4 ai aa aa a4 i

}

u I

o o

o o

o o

o o

o o

o o

o o

o o

o l

l l

TABLE (2)

I-SURVEILLANCE TESTPROCEDURE REVIEW Required Review May Require Changes STPw MODE Complete Change incorporated Prior to Start-up (Yes/No)

(Yes/Noi 0-001-1 1, 2, 3 Yes Yes O-004-1 1, 2, 3, 4 No 0-105-1 1, 2, 3 Yes Yes 0-009A-1 1, 2, 3 No i

C-010-0 l.2,3,4,5,6 No 0-027-1 1, 2, 3, 4 No 0-029-1 1, 2 No 0-033-1 1, 2, 3, 4 No 0-055-1 1, 2.', 4 No O-057-1 1,2,3,4,5,6 No

" O-062-1 1,2,3,4,5,6 Yes Yes O-063-1

1. 2, 3 Yes No N/R

~

0-064-1 1,2,3 Yes No N/R O-065-1 1,2,3,4,5,6 No 0-069-1 1, 2, 3 Yes Yes 0-070-1 1, 2, 3, 4 No 0-071-1 1, 2, 3, 4 No 0-072-0 1,2,3,4,5,6 No 0-073D-1 1,2,3,4,5,6 Yes Yes 0-073F-1 1,2,3,4,5,6 Yes Yes O-093-1 1, 2, 3, 4, 5,6 No O-095-1 1, 2, 3, 4 No 0-097A-0 1, 2, 3, 4 Yes No N/R

~

O-098-1 1, 2, 3, 4 Yes No N/R O-099-1 1, 2, 3, 4 No

~

O-100-1 1, 2, 3, 4 No l

O -102-1 1,2,3,4,5,6 Yes Yes Yes N/R = Not Required j

r 4

0 L

t TABLE (3) j PROCEDURE T!TLE INDEX g

O OPERATING PROCU)URES OP-1 Plant Startup from Cold Shutdown to liot Standby OP-2 Plant Startup from llot Stt5 dby to Minimum Load OP 3 Normal Power Operation OP-4 Plant Shutdown from Minimum Load to 110t Standby OP-3 Plant Shutdown from llot Standby to Cold ' shutdown I

i i

OPER ATING INSTRUCTIONS OI-2A Chemical and Volume Co'itrol System i

01-2 B CVCS Boration, Dilution & Makeup l

OI-2C Concentrated Boric Acid System Operations OI-2D Purification System Operation OI-2E Chemical Addition 01-3 Safety injection. Shutdown Cooling and Containment Spray OI-SC CEDM Cooling OI-8 A Steam Generator Blowdown System OI-8B Feedwater lleater Vents & Drains OI-8C Main Steam a,' Moisture Se,narator Reheater Vents & Drains Ol-8D Moisture Separator / Reheater Operation OI-9A Main Turbine Generator Lube C;l System GI-10A Seal Oil System OI-10B Generator Gas System 01-10C Sintor Cooling Water System OI-30D Generator Isolated Phase Bus Duct Coolins System liydrogen and CO Gas Storage System OI-10E 2

01-: 1A Condensate System 01-11B Precoat Fiiter System Ol-llc Condensate Demineralizer System l

01-11D Condensate and Feed System Layup and Layup Recovery i

1 i

l

-I-

)

i-

~3.

e TABLE (3)

,s 6

PROCEDURE TITLE INDEX g

OPER ATING INSTRUCTIONS (continued)

OI-12A Feedwater Systern 01-13 Ccadenser Air Removal OI-17E Reacter Coolant Waste Evaporator 1)(12) Operation 01-30 Nuclear Instrumentation 01-32 Auxiliary Feedwater System 01-42 CEDM Operation OI-43A Mam Turbine Generator / Exciter Operation OI-43C Main Turbine Performance Evaluation Checks SURVEILLANCE TEST PROCEl>URES O 001-1 Main Steam Isolation Valve Full Stroke Test 0-004-1 Integrated Engineered Safety Features Test 0-005-1 Auxiliary Feedwater System O-009A-1 Auxiliary Feedwater System Refueling Test 0-010-0 Spent Fuel Pool Exhaust Filter & Fans 0-027-l Reactor Coolant System Leakage Evaluation 0-029-1 Control Element Assembly Partial Movement 0-033-1 Radiation Monitoring System Functional Test O-055-1 Containment Integrity Verification O 0$7-1 Alternate AC Power Sources 0-062-1 Monthly Valve Position Indication O-063-1 Remove Shutdown & Post-Accident Monitoring Instrument Check O-064-1 Check of Safety injection Tank Feeder Breakers 0-063-1 Quartetty Valve Operability O-069-1 Steam Generator injection System & Contain Sp:ay Actuation Sys'em -

Log'a Test 0-070-1 Staggered Test 'A" Train 0-071-1 Staggered Test

'D" Train i

f i

- y<

TABLE (3)

PROCEDURE TITLE INDEX

['

l b,m.

l SURVFILLANCE TEST PROCEDURES (continued) 1 1

0-072-0 Control Room High Radhtion Test 0-073D-1 Charging Pump Test

{

L<

O-073F-1 Boric Acid Pump Test 0-093-1 Locked Yalve Verification j

0-095-1 Locked Yalve Inside Containment i

0-097A-0 No, il Control Room Air Conditioning Test 0-098-1 Containment High Range Radiation Monitoring System Test

(

O-099-1 Wide Range Noble Gas Monitor i

O-100-1 Main Steam Effit.ent Radiation Monitoring System Test j

O-102-1 Main Vent & Blowdown Radiation Monitorint, System f

i f

r I

i t

i I

b h

t,

- -.