ML19323D753

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 80-16, Shaft Seal Packing Causes Binding in Main Steam Swing Disc Check & Isolation Valves. No Written Response Required
ML19323D753
Person / Time
Site: Davis Besse 
Issue date: 04/29/1980
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Crouse R
TOLEDO EDISON CO.
References
NUDOCS 8005220278
Download: ML19323D753 (1)


Text

. TIC f-ag 6-4 UNITED STATES F

NUCLEAR REGULATORY COMMISSION a a REGION lil g

n

%,.... &"f o,

799 ROOSEVELT ROAD GLEN ELLYN, ILLINOIS 60137 APR 2 9130'-

Docket No. 50-346 Toledo Edison Company ATTN:

Mr. Richard P. Crouse Vice President Nuclear Edison Plaza 300 Madison Avenue Toledo, OH 43652 Gentlemen:

The enclosed IE Information Notice No. 80-16 provides information on two instances of main steam swing check or isolation valves binding due to shaft packing.

Sincerely, 84d i. D A

" James G. Keppler Director

Enclosure:

IE Information Notice No. 80-16 cc w/ encl:

Mr. T. Murray, Station I

Superintendent 1

Central Files Director, NRR/DPM Director, NRR/ DOR PDR Local PDR j

NSIC TIC Harold W. Kohn, Power Siting Commission Helen W. Evans, State of Ohio I

8N5sso 2 7f

n e

SSINS No.:

6870 1

Accession No.:

UNITED STATES 8002280667 NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, DC 20555 April 29, 1980 IE Information Notice No. 80-16 SHAFT SEAL PACKING CAUSES BINDING IN MAIN STEAM SWING DISC CHECK AND ISOLATION VALVES Description of Circumstances:

Recently two instances of binding of swing check valves have occurred.

During disassembly of the main steam isolation valves at Indian Point 2, it was observed that all four reverse flow check valves were stuck at or near fully open.

These 28" valves are manufactured by Atwood & Morrill Co.

Investigation revealed that this condition was apparently caused by excessively tight shaft packing which did not allow free movement of the valve disc.

This condition was reported on January 31, 1980.

An evaluation determined that with the existence of the reported condition in event of a main steam line break upstream of a main steam isolation valve together with coincident single failure of a main steam isolation valve to close in another loop, the potential existed for blowdown of the contents of two steam generators.

Main steam line break analyses applicable to Indian Point 2 have been performed assuming blowdown of the contents of one steam generator and have not considered multiple steam generator blowdown.

Therefore, it is possible that the reported condition could have contributed to the exceeding of a safety limit as defined in the Unit 2 Technical Specifications if a main steam line break had occurred.

The reported condition was corrected by adjusting the packing of these valves in all four loops and verifying that valve disc movement is not restricted.

During testing in the hot standby mode 't the Trojan Nuclear Plant on April 15, 1980, three of the four main steam line isolation valves failed to close when manually actuated.

The cause of the occurrence was binding in the shaft packing.

The valve is air opened and is closed by gravity, steam flow and a small spring force; the valves were manufactured by Atwood & Morrill Co.

The licensee believes that the valves would have closed during actual operations with steam flow in the line.

The valves were repaired aad tested satisfactorily.

Modifications to the valves to install air operators to help close the valves are being investigated by the licensee.

This Information Notice is provided as notification of a possible significant matter.

It is expected that the recipients will review the information for possible applicability to their facilities and appropriate corrective action taken.

No written response to this IE Information Notice is required.

1

IE Information Notice No. 80-16 Enclosure I

April 29, 1980 RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued To Notice No.

Issued 80-15 Axial (Longitudinal) 4/21/80 All light water reactor Oriented Cracking In facilities holding power Piping reactor OLs or cps 80-14 Safety Suggestions From 4/2/80 All power reactor Employees facilities with an OL or CP 80-13 General Electric Type SBM 4/2/80 All light water reactor Control Switches - Defective facilities holding power Cam Followers reactor OLs or cps 80-12 Instrument Failure Causes 3/31/80 All holders of power Opening of PORV and Block reactor OLs and cps Valve 80-11 General Problems with ASCO 3/14/80 All holders of Reactor Valves in Nuclear Application OL, CP, fuel fabrica-Including Fire Protection tion and processing Systems facilities 80-10 Partial Loss of Non-Nuclear 3/7/80 All power reactor Instrument System Power facilities holding Supply During Operation OLs and cps 80-09 Possible Occupational 3/7/80 All holders of Health Hazard Associated power reactor Ols with Closed Cooling Systems and near term cps i

80-08 The States Company Sliding 3/7/80 All power reactor Link Electrical Terminal facilities with an OL Block or a CP 80-07 Pump Shaft Fatigue Cracking 2/29/80 All Light Water Reactor Facilities holder power reactor OLs and cps 80-06 Notification of Significant 2/27/80 All holders of Reactor Events OLs and to near term OL applicants