101 MARIETTA ST, N.W.. SUITh 3100 ATLANTA, GEORGIA 30303 In Reply Refer To:
FEB 2 61980 RII:JWB 70-1113/80-02 General Electric Company ATTN:
R. J. Alkena, General Manager Wilmington Manufacturing Department P. O. Box 780 Wilmington, NC 28401 Gentlemen:
This refers to the inspection conducted by J. W. Bates of this office on ' January 28 through February 1, 1980, of activities authorized by NRC License No. SNM-1097 at Wilmington Manufacturing Department and to the discussions of our findings held with R. J. Alkema at the conclusion of the inspection.
Areas examined during this inspection included your program for nuclear material control and accountability under the applicable provisions of Title 10, Code of Federal Regulations, Part 70, "Special Nuclear Material", and specific license conditions. Within these areas, the inspection consisted of selective examina-tions of procedures and representative records, interviews with personnel, performance tests, and observations by the inspectors.
We have examined actions you have taken with regard to previously identified enforcement matters.
These are discussed in the enclosed inspection report.
One new unresolved item resulted from this inspection and is discussed in the enclosed report. This item will be examined during subsequent inspections.
During the inspection, it was found that certain activities under your license appear to be in noncompliance with NRC requirements.
These items and references to pertinent requirements are listed in the Notice of Violation enclosed here-with as Appendix A.
This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.
Section 2.201 requires you to submit to this office, within 20 days of your receipt of this notice, a written statement or explanation in reply including:
(1) corrective steps which have been taken by you and the results achieved; (2) corrective steps which will be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.
Details of activities involving safeguards and security measures are exempt from disclosure in accor-dance with 10 CFR 2.790(d). Therefore, your response should be incorporated in a separate paper and referenced in your reply.
In accordance with Section 2.790(d) of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, activities involving safeguards and security maasu=nu are exempt from public disclosure; therefore, the enclosures to this letter with the exception of the report cover page, which is an inspection summary, will not be placed in the Public Document Room.
MATE!"L TPJ.MS.'."TT7D !:r.'/'Til C0!!T*!::5 2.T: E 2 57.:..AT:3:1
MATERIALTRANSMiTTED HEREVHTH C0!;TA!!!5 2.700!Ki0;ii.AT10N General Electric Company FE B 2 61980 Should you have any questions concerning this letter, we will be glad to discuss them with you.
Sincerely,
~
g.B.Kenna, Chief Safeguards Branch
Enclosures:
1.
Appendix A, Notice of Violation (Exempt from Disclosure) 2.
Inspection Report No. 70-1113/80-02 (Exempt from Di= closure) 3.
Inspection Summary (Not Exempt) cc w/ encl:
A. L. Kaplan, Manager Licensing and Compliance Audits P. O. Box 780 Wilmington, NC 28401 C. M. Vaughan, Manager Nuclear Materials Management P. O. Box 780, Mail Code K-88 Wilmington, NC 28401 MATER:AtTRANSMITTED HERiWITH C011TA!!;S 2.7C3 I"FORh3T!03 7~
-