Nonproprietary Version of Memo Re Defective Welds in Neutron Shield.Employee Alleges That Info Re Potential Safety Problem Was Removed from Rept
ML19322D330
Person / Time
Site: Surry 
Issue date: 12/07/1976
From: Schnebelen A
NRC OFFICE OF INSPECTOR & AUDITOR (OIA)
To: Ryan W
NRC OFFICE OF INSPECTOR & AUDITOR (OIA)
Shared Package
ML19322D327 List:
References
FOIA-79-416 NUDOCS 8002110466
Download: ML19322D330 (1)


Text

___

0 0

h DEC 7 E6 HDORANDLD! FOR:

William Ryan, Acting, Assistant Director for Investigations Office of Inspector and Auditor l

ArthurSchnebelen[5 FROM:

Office of Inspector nd Auditor r

POTENTIAL SAFETY PROBLEM SURRY NO. 1 SU3 JECT:

During a recent interview I was conducting,regarding a pending investigation, an employee of.IE, NRC, advised me of a possible safety problem at Surry 1.,

The employee stated that wher$D was at Region II, a. -<-DW%

urry 1.

During an inspector with Reaion II,. conducted an inspection at the inspectionW~Nh found some bad welds in the neutron shield of The emp1ofe'eltated.thaC-had supported his findings of Unit 1.

bad welds with radiographs..However, upon returning to' the office, the principal inspector pulled this finding out of the report and in the According to i

exact words of the employee, " swept it under the rug."

the employee, the final report that was issued to the licensee did not further 4

mention the problem of the bad welds in the neutron shield.

stated that,inO opinion, if this is looked at today, the s e problem y

still exists and the plant would have to shut down.

The employee asked that if'possible,Q identification remain confidential.

9, 9

?+

9 ile DIA Reading

.?

Messenger 1

Abston Reading ASchnebelen WRyan Reading

\\

l q

=

s

(&

O A h en 1 -s D.

=a l

-.,,...

  • Ol g' [

OIA ASCHtEBELEly v.Gf fes 12/7/76 12/'//76 w....-..--. ~..- -.....w.......~.-

so u m a.,.rm muau.

L I46