..a.~

4 AEC DI7IBUTION F02 PART 50 DOCKET MA*"" RIAL (TEMPORARY FORM)

CONTROL NO: 8450 t

s FILE:

FRW:

DATE OF DOC DATE REC'D LTR MEMO RPT OTER Duke Power Company

)

Charlotte, N. C. 28201 11-21-73 11-26-73 X

A. C. Thies TO:

ORIG CC OTER SENT AEC PDR X

A. Giambusso 1 signed SENT LOCAL PDR X

CLASS UNCLASS PROP INFO INPUT NO CYS REC'D DOCKET NO:

XXXX 1

50-269 DESCRIPTION:

ENCLOSURES:

Ltr re their 10-25-73 ltr, furnishing addl info to Unusual Rpt UE-269/73-8, re " Main Steam Re-lief Valve Operation"..................

ACKNOWLEDGED DO NOT REMOVE PLANT NAME: Oconee Unit 1 FOR ACTION /INFORMATION 11-26-73 GC BUTLER (L) f WENCEP/L)

ZIDIANN(L)

REGAN(E)

W/ Copies W/ 7 Copies W/ Copies W/ Copies j

CLARK (L)

STOLZ(L)

DICKER (E) j W/ Copies W/ Copies W/ Copies W/ Copies GOLLER(L)

VASSALLO(L)

KNIGHTON(E)

W/ Copies W/ Copies W/ Copies W/ Copies KNIEL(L)

SCHDIEL(L)

YOUNGBLOOD(E)

W/ Copies W/ Copies W/ Copies W/ Copies INTERNAL DISTRIBUTION CREG F TECH REVIFW DENTON A/T IND i

C PDR M NDRIE GRIMES LIC ASST BRAI'IMAN A(UNIZING/ STAFF C, ROOM P-506A SCHROEDER GAMMILL DIGGS (L)

SALTDIAN

,A dACCARY KASTNER GEARIN (L)

B. HURT ydLSE v4 NIGHT BALLARD dOULBOURNE (L)

PMNS GIAMBUSSO v1AWLICKI SPANGLER LEE (L)

MCDONALD BOYD wdlEA0 MAICRET (L)

DUBE MOORE (L)(BWR)

.4ITELLO ENVIRO SERVICE (L)

AEYOUNG(L)(PWR)

AIOUSiON MULLER SEPPARD (E)

INFO SKOVHOLT (L)

A 0VAK DICKER SMITH (L)

C. MILES P. COLLINS witOSS KNIGHTON 7T.ETS (L) d. KING (RO) vfPPOLITO YOUNGBLOOD WADE (E)

[EGOPR M ESCO REGAN WILLIAMS (E)

FILE & REGION (3)

WNG PROJECT LDR WILSON (L)

RRIS pfAINAS g/

/O STEELE w1ENAR0fA HARLESS T91$

I-

/VOLINER C,1 ~.'

EXTERNAL DISTRIBUTION lA vf - LOCAL PDR Walhalla, S. C.

vf - DTIE(ABERNATHY)

(1)(2)(10) NATIONAL LAB'S 1-PDR-SAN /LA/NY

- A - NSIC(BUCHANAN) 1-ASLBP(E/W Bldg,Rm 529) 1-GERALD LELLOUCE l

1 - ASLB(YORE /SAYRE/

,1-W. PENNINGTON, Rm E-201 GT BROOKHAVEN NAT. LAB j

WOODARD/"H" ST.

1-CONSULTANT' S 1-AGMED(Ruth Guss:can)

/16 - CYS ACRS2pammer SENT TO LIC. ASST.

NEWMARK/BLUME/AGBABIAN RM-B-127, GT.

l 11-26-73 Goulbourne 1-GERALD ULRIKSON...ORNL l-RD.. MULLER..F-309 G'

r e

Regulatorj Docket File nuxz Powza coxvixv Powza Buzz.orwo 422 SouTu Caraca StartT, CuAnzoTTE,N. C. asaos A, C. THIES P. o. Box a17e SENIOR VICE PRESIDENT g

N [-.

000gD 3

e.oouctio= *~e vaan,m.io=

g NOV 261973 * (.

November 21, 1973 RE PLATSRY h[

d

^

C(/

A'A!L *iC"N h

l s

I;CK CLE.T,j f's l' A -

l 4

Mr. Angelo Giambusso N / Q g

Deputy Director fer Reactor Pro.je w

Directorate of Licent.'ng

,4 Office of Regulation U. S. Atomic Energy Commission

)

Washington, D. C.

20545 Re:

Oconee Unit 1 Docket No. 50-269

Dear Mr. Giambusso:

My letter of October 25, 1973 transmitted to you Unusual Event Report UE-269/73-8, " Main Steam Relief Valve Operation." This report stated that the main steam relief valves for Oconee Unit I had lifted following reactor trips from power levels less than 40 percent full power. The Oconee FSAR states that the combined actions of the control system and the turbine bypass valves should permit a 40 percent load reduction or a turbine trip from 40 percent load without safety valve action.

We indicated that further testing of the turbine bypass system, including a turbine trip test from 40 percent power or higher, was necessary and that we would keep you advised of the results.

On October 27, 1973, a turbine trip test from 40 percent full power was conducted. The turbine bypass system functioned as designed and the main steam relief valves did not lif t.

The turbine bypass systems for both Oconee Unit I and 2 have been modified to supply adequate motive force to the bypass valves.

These modifications should prevent any recurrence of this incident.

l Very truly yours, A. C. Thies ACT:vr cc:

Mr. Norman C. Moseley l

C 150