ML19321A805

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 80-20, Loss of Decay Heat Removal Capability at Davis-Besse Unit 1 While in Refueling Mode. No Response Required
ML19321A805
Person / Time
Site: Grand Gulf  
Issue date: 05/08/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Stampley N
MISSISSIPPI POWER & LIGHT CO.
References
NUDOCS 8007240218
Download: ML19321A805 (2)


Text

- _ --_. _ _

/

'o,,

UNITED STATES NUCLEAR REGULATORY COMMISSION o

E REGION 11 o

I 101 MARIETTA ST., N.W SUITE 3100 ATLANTA, GEOROLA 30303 MAY 8 1980 In Reply Refer To:

RII:JPQ _ __

gf 50-417 y Mississippi Power and Light Company Attn:

N. L. Stampley Vice President of Production P. O. Box 1640 Jackson, Mississippi 39205 Gentlemen:

The enclosed Information Notice provides early notification of an event that may have safety significance. Accordingly, you should review the Information Notice for possible applicability to your facility.

No specific action or response is requested at this time; however, con-tingent upon the results of further staff evaluation, a Bulletin or Circular recommending or requesting specific licensee actions may be issued.

If you have questions regarding this matter, please contact me.

Sincerely, m

_A N' James P. O'Reilly Director

Enclosures:

1.

IE Information Notice No. 80-20 2.

List of Recently Issued IE Information Notices f

., n:

I I'1 l

QY.h,

-,.a.

1 3 ~,. z.,

?E3 [~;*.

NP ei==ar4 8007240218

~ ~ ' ~

~

,,.,E,

~~

~.

Q.

MAY 81%

o Mississippi Power and' Light Company cc w/ encl:

C. K. McCoy Plant Manager Post Office Box 756 Port'Gibson, Mississippi 39150 s

e e

9 i

b

'~

h a

I

SSINS No.:

6870 UNITED STATES Accession No.:

NUCLEAR REGULATORY COMMISSION 8002280671 0FFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, O. C. 20555 May 8, 1980 IE Information Notice 80-20 LOSS OF DECAY HEAT REMOVAL CAPABILITY AT DAVIS-lESSE UNIT ~1 WHILE IN A REFUELING MODE Description of Circumstances:

On April 19, 1980, decay heat removal capability was lost at Davis-Besse Unit I for approximately two and one-half hours. At the time of the event, the unit was in a refueling mode (e.g., RCS tempersture was 90F; decay heat was being removed by Decay Heat Loop No. 2; the vessel he :d was detensioned with bolts in place; the reactor coolant level was slightly below the vessel head flanges; and the manway covers on top of the once through steam generators were removed).

(See Enclosure A, Status of Davis-Besse 1 Prior to Loss of Power to Busses E-2 and F-2 for additional details regarding this event.)

Since the plant was in a refueling mode, many systems or components were out of service for a.aintenance or testing purposes.

In addition, other systems and components were deactivated to preclude their inadvertent actuation while in a refueling mode. Systems and components that were not in service or deac'ivated included:

Containment Spray System; High Pressure Injection System; Source Range Channel 2; Decay Heat Loop No. 1; Station Battery IP and IN; Emergency Diesel-Generator No. 1; 4.16 KV Essential Switchgear Bus C1; and 13.8 KV Switchgear Bus A (this bus was energized but not aligned).

In brief, the event was due to the tripping of a non-safeguards feeder breaker in 13.8 KV Switchgear Bus B. Because of the extensive maintenance and testing activities being conducted at the time, Channels 1 and 3 of the Reactor Protec-tion System (RPS) and Safety Features Actuation System (SFAS) were beir.g ener-gized from only one source, the source emanating from the tripped breaker.

Since the SFAS logic used at Davis-Besse is a two-out-of-four input scheme in which the loss (or actuation 7 of any two input signals results in the actuation of all four output channels (i.e., Channels 1 and 3, and Channels 2 and 4), the

~1oss of power to Channels 1 and 3 bistables also resulted in actuation of SFAS Channels 2 and 4.

The actuation of SFAS Channels 2 and 4, in turn, aff gttd - -

~<

Decay Heat Loop No. 2, the operating lyn e r.s

~

.g ya m m+g TA" H]

Since the initiating event was a loss 6 a

!j wereactuated(i.e., Level 1-HighRadQ DUPLICATE DOCUMENT tion; Level 3 - Low Pressure Injection ['d Entire document previously i

e' entered into system under:

J ANo f o o W 5 0 /o 7 /

ue w

n No. of Pages:

,/

.I g

h.

.-