Forwards IE Circular 80-13, Grid Strap Damage in Westinghouse Fuel Assemblies. No Written Response Required
ML19320D521
Person / Time
Site: Crystal River 
Issue date: 05/28/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Hancock J
FLORIDA POWER CORP.
References
NUDOCS 8007210462
Download: ML19320D521 (1)


Text

____________ _ _ _ _ _ _ _ _ _ _ _ _

U "o,,

UNITED STATE $

8 NUCLEAR REGULATORY COMMISSION 3

E REGION 11 h

o#

101 MARlETTA ST., N.W., SUITE 3100 g.....o[

V ATLANTA, GEORGIA 30303 In Reply Refer To:

28 980 THIS DOCUMENT CONTAINS POOR QUAllTY PAGES Florida Power Corporation Attn:

J. A. Hancock, Director Nuclear Operations P. O. Box 14042, Mail Stop C-4 St. Petersburg, Florida 33733 Gentlemen:

e The enclosed Circular No. 80-13, is forwarded to you for information.

If there are any questions related to your understanding of the suggested actions, please contact this office.

Sincerely, U ^%'

James P. O'Reilly Director

Enclosures:

1.

IE Circular No. 80-13 2.

List of Recently Issued IE Circulars 1.

i 80012.10h2

MAY 281880 Florida Power Corporation.

cc w/ encl:

D. C. Poole Nuclear Plant Manager Popt Office Box 1240 Cr'ystal River, Florida 32629

\\

. -/

4

o k

SSINS No.: 6830 Accessions No.:

UNITED STATES 7910250495 NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C. 20555 e

May 28, 1980 IE Circular No. 80-13 GRID STRAP DAMAGE IN WESTINGHOUSE FUEL ASSEMBLIES Description of Circumstances:

During the refueling operation at Salem Unit 1, it was noted by the licensee that some of the assemblies that were removed had suffered grid strap mechanical damage. This was reported to the NRC in LER 79-44.

Subsequent to-this discovery all fuel assembli,es were removed from the core for examination.

The degree of the damage to the grid straps was classified in three cate-gories: small pieces missing (15 assemblies), grid material ripped and laid over (5 assemblies), larger sections missing and fuel pins exposed (11 assemb-lies). No damage to the fuel pins was observed. A total of 31 assemblies suffered some grid damage.

The damage appeared to be the result of corner to corner interaction of the grid straps of diagonally adjacent fuel assemblies during the vertical loading and unloading movements.

No correlation of the damage to core location, grid strap elevation, or manufacturing and shipping batches has been identified.

The licensee and the fuel manufacturer established the following guidelines for reloading damaged assemblies: (1) those assemblies with full width pieces i

missing will not be reloaded for cycle 2, (2) those assemblies with deformed j

edges and those with small pieces missing will be reloaded with special pro-cedures to prevent further damage.

Salem Unit 1 is fueled with 17X17 Westinghouse assemblies. Similar grid problems have occurred at other facilities fueled with 14X14 and 15X15 Westinghouse assemblies; however, fewer assemblies were damaged in those instances.

Recommended Actions:

+

All licensees using 14X14, 15X15, or 17X17 Westinghouse assemblies are advised to:

j (1) Visually inspect grid straps of those fuel assemblies which are i

. discharged from the core as well as those assemblies which are moved to the spent fuel pool for control rod replacement and are subsequently returned to the core.

l-

+. -

-gp y

- p. j eye mW re. m-tin <,m gen s* w

~

'V

m IE Circular No. 80-13 May 28, 1980 Page 2 of 2 (2) Review the fuel handling precautions recommended by Westinghouse at a meeting on May 25, 1979, with NRC and the licensee for Salem (Attachment 1). Adopt those reco:nmendations which are pertinent.

No written response to this Circular is required.

If you require additional information regarding these matters, contact the Director of the appropriate NRC Regional Office.

Attachment:

Summary of Meeting Notice dated 5/30/79 6

4

~

h

,..,m4 gy

.p

_p 4d***

~' ' '**-* ~~*

'""~"*T**-"-

7 x

gy a I.,

.ww t.

A,

y.,

6 l ',gi%

q 4f i.

q r-

.7 M 7?. 7.q g y 3r M Fy 7

  • l

. 3 t.

+.dh %(IM.QMW, j

P, n

4 o

.m...

UNITED STATES

.:j t 1 i R NUCLEAR REGULATORY COMMISStOft: + $ Peg $$ F$T!Mi-4 4 h.. '..m..W8P 8 C '""

-

  • m =. y y M '-urs.

a

,%m.

3.y. e

- m-

.,q.-.

~ym.9yymrw

. j.q j yp.

m,.,

g ;.;,;;.ep

~,

.m.w.

-c1 e

Docket ilo. Shi?N' +

I 4

4

.g.

.4v.

~

LICENSEE:

PUBLIC SERVICE ELECTRIC & GAS COMPANY (PSE&G) g gJe kN"

"M Ni l

FACILITY: SALEM UNIT NO. 1

.)e

^ "

SUBJECT:

StM RRY OF MEETING HELD ON MAY 25. 1979. TO DISCUSS

}

DAMAGE OBSERVED TO FUEL GRID ASSEMBLIES DURING THE Mr % %d'M SALEM LMIT NO.1 REFUELING OUTAGE '

u-

.e

. o.,

On May 25, 1979, we met with repr'esentatives of Public Service Electric &

't Gas Company (PSE&G) and Westinghouse to discuss the cause and extent of damage observed to the Salem Unit No.1 fuel grid assenb, lies during the current refueling outage for cycle 2.

A list of attendees is enclosed.

4h

  • F 3 lirfQ
i Significant discussions are summarized below.

.. ;a.X6W - ~ 7%3;iiin The licensee and Westinghouse provided a detailed discussion of the damage observed to the Salem fuel grid assemblies during the cycle 2 in*b...xW"e.t ?

'+

' refueling outage which cocmenced in April 1979.

Due to the indications

. observed during the initial stages of the outage, the decision was ende to unload all fuel assemblies from the core.

Of the fuel assemblies (193) inspected, 28 assemblies were detemined to have varying degrees Q',s of damage to one or more of the eight grid asserablies per fuel assembly.

t The grid assemblies provide lateral support to the fuel rods.

In no case was damage observed to the fuel rods themselves.

The grid assembly damage observed, which was generally located at the corners of the grid assemblies, wks categorized as follows:

l Category Type of Dan: age No. of Grid Assemblies

-Mh;hh$th 1

smell pieces missing 15 2

grid material ripped and laid over 4

3$7$8?

3 larger sections missing and S

,,,g g,,,._, e fuel pins exposed

.- d -

Fp t

m rx N,

.c m uu m b s

g l..f;....

' t$ '

.:-eVgh.${44Nm g-wt.;gs,* h

_ o owo w-

cv

'-T u p C - :

p

]

)

~~..gV 1

  • h i b p m '-,

n.. y a.9 y m

. m.~. m __; +, w,.-~ -:

~

} 4ia h b a.,4,2,.. 4.4. a mMM.sJs. s... a E 4

s

,n

- w.

eu myp.:

.m

p y.m Meeting Summary forOh ~ ' " ' '. *T y' a

.n-w 6 Salem Unit 1

-B-b"* r"." ^ h --

j

  • p rdr re m.wwo w n - p ~~&

4.--m mm

  • rw.*

g

! '"';Ok tidajWeT9id1Ts'ses611es witfcategories Y and i ds' mage 'seF l

g determined ty the licensee to be acceptable-for use and will be reloaded a

,_ for cycle 2i as a precautionary measure assemblies with category 3 damage will not be reloaded. The basis for this detennination was that assemblies with category 1 and 2 damage can be used without any loss of function of e

m 4, _

.<d..

r i... u v..

.,4 %..*.a..y 3 a

.o..

w........

longer fully restrain all fuel rods in the manner provided for in the

. design. Their reuse should be based en further analysis.

Of the data collected and the reload films reviewed, no pattern has been established for the observed damage. Also, it has not been detennined whether the damage occurred during fuel insertion for cycle 1. or during reseval or readjustments for cycle 2. or both.

It is believed that comer-to-corner interaction may have occurred between grid assemblies

.~

of adjacent fuel assemblies especially when diagonal fuel assemblies have been removed and some degree of lateral movement is possible.

Under these conditions the grid assemblies may have been aligned such that the corners interacted during vertical movement.

Of the pieces missing (about 61), a total area of about 25fn2 is involved.

These pieces range from about.3fnz up to about S. Sin 2 Approximately 12in2 of material has been recovered from' the core or the fuel assemblies during the unloading of the core.

In addition, the core was inspected with a TV camera. With regard to the potential for flow blockage from the missing material. Westinghouse indicated that if all the peices originally missing were to be located such as to partially block the inlet nozzle area of the one fuel assembl, analyses similar to that described in Section 3.4 of the Salem FSAR indicate that no problem would exist. The i

smaller pieces still missing are expected to easily pass up through the fuel assemblies during operation and not present any problems to the control rod drive mechanisms.

Tha largest that any of the missing pieces could be than ZinE. based on the base areas on grid assemblies, is slightly greater Westinghouse has recommended additienal fuel assembly handling precautions to minimize the potential for corner-to-corner ir.teraction between grid assemblies.

Included among these reconnendations are,1) a revised loading sequence which would load fuel assemblies from the sides of the core toward the center, 2) a slight offset in position as corner fuel assemblies are lowered into the core until they are about 10" above the base plate and then making a lateral adjustment into final position,

3) the conditionally accepted assemblies in categories 1 and 2 would be loaded in a special sequence to minimize relative motion with adjacent assemblies. 4) those assemblies in category 2 would be loaded against the core baffle, where possible and 5) revised load cell limits on the mani-pulator crane in an attempt to more easily detect increased loads during fuel handling.

m.

  • f*k M.

I.,

sw-g*

dF,

pT. O **

i

+9e se@+=se.e.gge-w.g e'w-ema e,,s.eeu e ey.

.n, u,. ~... gv,..,-

,..g w.n

.r..

.-c.~........s..,,

..j;,.- +.

.i.

,~

3 '. Meeting Sumarkfor

~

< 4

....2

..re - a

.j c.p.

U Salem Unit 1

- ~ -"." ^

' > - 1 e

r-,

.. w.,g;u o.;w w.4+

.. emv s...

-w

- rs:

v m:.-

"? ' WestinNoisitYel5Isiwiedged and sumarized'~simils' grid'assem51['pNbisid~ "~~

r

.Q' -

tha't havs oc.asrred at other facilities. Although these other occurrences x

4 did not involve as mary fuel assemblies as in this Salem situation,

~ imilar damage has been observed to 14x14,15x15 and 17x17 fuel assemblies.

s

+'

In some instances the fuel was removed, and in others, the fuel was re-

loaded with no known adverse effects.

With regard to the Sales unit 1 refueling aanlysis, the licensee indicated Pre 11minarily, that the core parameters are expected to be essentially

, unchanged due to the revised core loading that will result.

The licensee agreed to address the potential effects that the unaccounted for pieces of grid material might have on the core thermal hydraulic analysis and on control rod operation.

This infonnation will be included prior to restart of Salem 1 in a supplement to the licensee's reload application for c;ycle 2.

J_

-w Gary G.

h. Project Manager Operating Reactors Branch #1 4

Division of Operating Reactors

Enclosure:

List of Attendees cc: w/ enclosure i

See next page i

'.i

\\

~

I

,-e..

,.... w:,.:

..w..

.,. m

l

.y y.,..,

5 t

w e,

.v

..,4..,.

4 IE Circular No. 80-13 Enclosure g

May 28, 1980 RECENTLY ISSUED IE CIRCULARS Circular Subject Date of Issued to No.

Issue 1

80-13 Grid Strap Damage in 5/28/80 All holders of Reactor Westinghouse Fuel Assemblies OL and Construction Permits for PWRs 80-12 Valve-Shaft-To-Actuator Key 5/14/80 All holders of Reactor May Fall Out of Place When OLs and cps Mounted Below Horizontal Axis 80-11 Emergency Diesel Generator 5/13/80 All holders of a power Lube Oil Cooler Failures reactor OL or CP 80-10 Failure to Maintain 4/29/80 All holders of Reactor Environmental Qualification OLs and cps of Equipment 80-09 Problems With Plant Internal 4/28/80 All holders of a power Communications Systems reactor OL or CP 80-08 BWR Technical Specification 4/18/80 All General Electric Inconsistency - RPS Response BWR's holding a power Time reactor OL 80-07 Problems with HPCI Turbine 4/3/80 All holders of a power Oil System reactor OL or CP 80-06 Control and Accountability 4/14/80 Medical licensees in Systems for Implant Therapy Categories G and G1 Sources 80-05 Emergency Diesel-Generator 4/1/80 All holders of a power r,

Lubricating Oil Addition and reactor OL or CP

}. ~

Onsite Supply 80-04 Securing of Threaded Locking 3/14/80 All holders of a power Devices on Safety-Related reactor OL or CP Equipment 80-03 Protection from Toxic Gas 3/6/80 All holders of a Hazards power reactor OL 30-02 Nuclear Power Plant Staff 2/1/80 Ali holders of Reactor

' 3 Work Hours-OLs, including research and test reactors, and cps

k _, ;

_g..~.--

- ~ [--- ;--] - -

.__