RO 50-313/77-5A:on 770128,pinhole Leak Observed on pipe-to- Flange Weld Between Valve & Seal During Routine Investigation.Cause Unknown.Defective Weld Repaired During Refueling Outage
ML19320A150
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 04/08/1977
From: Mardis D
ARKANSAS POWER & LIGHT CO.
To:
Shared Package
ML19320A146 List:
References
NUDOCS 8004140743
Download: ML19320A150 (4)


Text

~

OCENSEE EVENT REPORT ~.

CdNTROL 8 LOC .i l l l l I I (Maams N ALL M M4 o NAME 1 e LCENSE NUMSEA lAIRikltIRItl lo lo l-lo lo le loIol-loIe25i 14 l i h I i li30i lo ir F89 14 15 26 31 3E CAffGORY TV A OOCKET NUM8EA EVENT 3 ATE meP0fri OATE O 1 CONT l l l [Q_l [.$d 1015lol-lo13l113l88 lo 89 i l I t I t 1717 l l 014101811 h ]

74 75 W 7 8 57 58 59 60 61 EVENT '1ESCRIPTION DE l b Rtri SaQTthodd t este m o u s tm:.W 4 6 h toWT s4E mas %- TuEch% 1 4 9 45'1 % Attn a . }

E 7 89

$ l A hwM. t.sau. wms omstr.ote ow w het- To -stasest sists wrwet4 tMNE I 7 89 E 3! I hi-ME huo " C ILc 9 *irut. . "Tuw 19twv WAs n 94,9ETstwc occutasm .

7 89 El HE I (so-se/ i t-rA3 7 89 '

gl l

EilB I 7 69 m 80 CIoE COMPONENT CODE MANUFACTUWI WRATIDN BE Ic IB I [f_] le li IP If lY IX l lEl 11 la ls.141 [MJ 7 89 10 11 12 17 43 44 47 48 CAUSE DESCRIPTION 8l Sk I, 7 89 - M DE I \w w u not m was n eniete co u.u m r a esar u v u tus a l 7 89 80 I cerrAsc . l

00 s oo EA oT EA STAruS 7JEEK omonAv oE.CA. TON (B.J lololol I ww I lkj l nA l 7 8 9 10 12 *3 44 45 46 80 A LE S D OF E ASE AMOUNT OF ACTMTV LCCATON OF RELEASE i

7 8 9 LL l!J 10 l

11 a l 44 I

45 wx I, 80 I PERSONNEL EXPOSURES l NUMBER TYPE DESCASTON I DE lo lolol lEj l uA II 7 89 12 13 11 80 i PERSONNEL INJURIES I NuMsEA DESCA@ TON DE lo lo lo l 7 89 I un I 11 12 80 -

OFFSITE CONSEQUENC:.3 32 l MA I 7 89 80 LOSS OR OAMAGE TO FACILITY TYPE DESCASTON 3 lEj l %A l 7 89 10 80 '

PUBLICITY 1 l  %% A / I 7 89 '

l g- 4 80 ADOITIONAL FACTORS j l wk I 89 80 19 I 8004140 D l NAME: h\hD - D%5 PHONE: soMi - 4 M

. ......T

, .. t^

G

1. Reportable Occurrence Report No. 50-313/77-5A
2. Report Date: 4-8-77 3. Occurrence Date: 1-28-77 1

4 Facility: Arkansas Nuclear One-Unit 1 l Russellville, Arkansas

5. Identification of Occurrence:

A leak on the pipe to flange weld between valve RBV-77B and "B" RCP seal.

j

6. Conditions Prior to Occurrence:

Steady-State Power Reactor Power 0 MWth Hot Standby Net Output 0 gwe Cold Shutdown Percent of Full Power 0  %

Refueling Shutdown Load Changes During Routine Power Operation Routine Startup Operation Routine Shutdown Operation Other (specify) Hot Shutdown

7. Description of Occurrence: -

At approximately 0200 hours0.00231 days <br />0.0556 hours <br />3.306878e-4 weeks <br />7.61e-5 months <br /> on January 28, 1977, during a routine walk-through inspection by Operations Personnel prior to cooldown, a pinhole leak was observed on the pipe-to-flange weld between Valve RBV-77B and "B" RCP seal. Valve RBV-77B servas as a means of 6nting the "B" RCP seal during initial fill of the RCS. The leak could not be isolated. -

x

.~- _

y

)

_) Reportable Occurrence Report No. 50-313/77-5A

8. Designation of Apparent Cause of Occurrence:

Design Procedure Manufacture Unusual Service Condition Including Environmental Installation /

Construction Conn onent Failure (See Failure Data)

Operator Other (specify) , X ,

Unknown

9. Analysis of Occurrence:

The Reactor Coolant System leakrate prior to snutdown was approximately '

O.S GPM. Since the leakage was contained in a controlled area, there was no hazard to the health and safety of the public.

O O-l

_ _ . - _ _ _ _ _ _ _ _ . - _ - - - _ - . _ _ _ . . . . , - _ - ._.1 -

1 Reportable Occurrence Report No. 50-313/77-5A r

10. Corrective Action:

The defective weld was repaired during the recent refueling outage by grinding and rewelding.

! 11. Failure Data:

l This is the second failure in this area. See Abnormal Occurrence I

Report 74-14.

i i

a l

i e

l I

i f

l 1 i

1 l

l l

l