ML19320A067

From kanterella
Jump to navigation Jump to search
Forwards RO 50-313/76-29 & 50-313/76-30
Date released: 11/30/2019 Download: ML19320A067


RO 50-313/76-30:on 761003,primary Makeup Pump P36B Failed. Caused by Horizontal Double Bearing Pump Dvmx Failure.Pump Disassembled,Inspected & New Parts Ordered
ML19320A078
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 11/01/1976
From: Cook R
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19320A078 (4)
RO 50-313/76-29:on 761003,leak Found at Socket Weld in Primary Makeup Pump P36C Suction Relief Line.Caused by Subjection of 6-inch Suction Line to Vibration,While 3/4 Inch Relief Line Is Rigidly Supported.Pump Inspected
ML19320A072
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 11/01/1976
From: Cook R
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19320A072 (4)
Forwards RO 50-313/76-29 & 50-313/76-30
ML19320A066
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 11/01/1976
From: Rueter D
ARKANSAS POWER & LIGHT CO.
To: HOWARD E M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19320A066 (1)