ML19319C055

From kanterella
Jump to navigation Jump to search
Evaluates Util Proposed Corrective Action Re Shipping Damage to Facility Primary Pump Casing.Corrective Action Satisfactory,Providing Distortion or Surface Discontinuity Not Shown in Dimensional & Liquid Penetration Insp
ML19319C055
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 08/07/1972
From: Potapovs U
US ATOMIC ENERGY COMMISSION (AEC)
To: Reinmuth G
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML19319C044 List:
References
NUDOCS 8001300793
Download: ML19319C055 (1)


Text

. _ _ _ _ _ _ _ - _..

\\

I l

C. W. Reineuth, Chief Technical Assistance Branch, 10 SHIPPING DAMAGE TO DAVIS-BESSE PRDERY PIMP CASING (LIEENSEE CDR DATED 7-27-72)

The corrective action proposed in the licensee's CDR appears satisfactory providing that the dimensional measurements and liquid penetrant inspection ed the pump volute show no evidence of distration or surface discontinutess, respectively.

The liquid penetrat test should include both inside and outside surfaces.

If any rejectable PT indications are observed, re-radiography of the casting should be considered. The shop inspection results and rework procedures should be reviewed during follow-up inspections.

~

h

....ta Senior Motta11urgical Engineer l

l omer >

..R,0, TAB R'sul L 4 P z

sunnaug, UPp,tappvs.,,,,,,,

,,,, g,,

5 J

om,

7nn2..

......R.0 0 Form AEC-31s (Rev. 9-53) AECM 0240

v. s. GOVERNMENT PRINTDiG OFFICE : 1970 0 - 405-346