o Lan,eIb,u..ha.c gan Papers HOW THE BAILLY NUCLEAR PLANT COULD DRY UP THE DUNES NATIONAL LAKESHORE MUST ENERGY IMPACT. RECREATION?

ABSTRACT Construction of the Bailly nuclear power plant by the Northern Indiana Public Service Company requires with-drawing water from the same water supply that feeds the Indiana Dunes National Lakeshore and the Cowles Bog.

Termination of present alkaline seepage into the aquifer from ash-ponds will further aggravate the problem.

Al-though extensive studies have been completed to model the effects, certain situations have not been analyzed.

The effect of termination of seepage has not been studied.

Nor has the newly discovered need to draw. water from the lower aquifer or the effect of a " window" in the Cowles Bog.

The injection of new water to cure withdrawal may cure quantity problems but could cause problems with the " quality" of the water.

The Federation recommends that pumping be halted until studies are completed, that the U.S. Geological Survey continue its studies and insure they are comprehensive, that a competent team be assembled to study the effects of dif ferent quality of water being injected and that the National Park Service exert a strengthened role in pro-tecting the Lakeshore.

Carol Newcomb and Richard L. Robbins-Lake Michigan Federation 53 W. Jackson Blvd.

Chicago, Illinois 60604

- March, 1980 -

800630037J

,.~

INTRODUCTION Will the construction of the Bailly nuclear power plant in northern Indiana on the ahores of Lake Michigan have an adverse effect on the Indiana Dunes I;ational Lakeshore nearby?

The question has been raised for a number of years.

Initially, in 1974 when the plant was given a construction permit by the federal government, the national lakeshore effects were not seen as significant enough to halt the plant.

And NIPSCO (Northern Indiana Public Service Company) continued to design the plant.

Later even the National Park Service (NPS), custodian of the lakeshore at that point, failed to raise significant objections that could halt the construction of the plant.

Now, 1980, with the plant less that 1*. complete, only a construction exca-vation as evidence of a powerful reactor to-be, the questions have arisen again.

They are, not tha older questions.

Those were quite straightforward.

They include:

Would a massive sixteen story cooling tower upset the natural feeling of the lakeshore?

Even when paired with a similar tower adjoining the eastern end of the park, the answer was negative.

Not enough effect.

Would a combination of mist from the cooling tower and sulphur from an im=ediately adjacent coal-fired plant cause intense acid rain, affecting the lakeshore park and nearby residents?

Not even the U.S. Environmental Protection Agency, nominally the protector from such problems, concurred.

Every nuclear power plant near populated areas requires an evacuation plan.

Could such a plan be designed that would work for the transient visitors to the national lakeshore?

The problem was not considered significant enough to stop the plant.

Only recently, since Three Mile Island, have evacuation plans become important constituents of nuclear power plant operations.

And of course, there was always the safety of a nuclear plant _especially one so close to Chicago.

Today, Bailly probably could not be licensed.

But when Bailly received its parmit the proximity made little difference..

1

t' 2-Beyond these older questions, some of which still persist, have arisen a whole new series of new questions.

Some get mixed up with the older ones, and are inextricable.

For example, NIPSCO is asking for an extension of the construction permic which expired in September 1979.

Perhaps the newer and the old issues must be determined again if the permit is to be changed.

Unique, however, among the new issues is one that is critically important to the national lakeshore.

That issue is water.

Clearly the lakeshore vegecation cannot function without adequate supplies of the right quality water.

Even too much can make a difference to the amount and kind of vegetation.

And a differ'ent type of water, more acid or more basic, can change the vegetation as well.

The level, continuity and quality of the water supply can be critical.

Back to the excavation now.

NIPSCO is digging an enormous pit now for the various buildings that com-prise a nuclear power plant.

At some points the excavation is or will be more than forty feet deep, deeper than lake level.

Of course, digging that deep in that type of land means that NIPSCO is digging in the aquifer.

What is an aquifer?

An aquifer is an underground supply of water.

The loose sand and gravel under the Bailly site contains enormous quantities of water.

Wells are dug to this unde

- -i supply.

Even more,there _ce two aquifers beneath the Bailly site.

An unconfined aquifer exists near the surface.

Then below it at some point is a con-fining layer of clay.

Water cannot flow easily through clay.

Below that clay is a second aquifer, called a confined aquifer.

In order to dig the hole for the Bailly nuclear plant NIPSCO must pump water out of the excavation.

This is called dewatering.

Although NIPSCO built a confining " slurry" wall around the excavation to try and keep water out, NIPSCO was still pumping water from the upper aquifer.

Either the " slurry" wall leaked or water from the lower aquifer was in the excavation.

In later 1979 it became clear that NIPSCO vould also need to pump water from the lower aquifer as well to prevent " boils" from occurring as water was forced upward.

Both of these aquifers are under the Indiana Dunes National Lakeshore as well.

And water' drawn from one part of the aquifer is also drawn from another.

Both aquifers also underlie the Cowles Bog, a national monument preserved for its unique plant species.

The National Park Service and the public became worried.that water pumping at the Bailly site could affect the Cowles Bog and the entire Dunes National Lakeshore.

To remedy these difficulties NIPSCO has proposed the injection of clear water into the aquifer to remedy the outflow should the water levels impair park vegetation.

)

.. For over ten years now water has been drained into the aquifer from two ash settling ponds where NIPSCO dumps a slurry of ashes from its coal fired plant nearby.

Over 1.000,000 gallons a day drain from the ash ponds and seep into the lakeshore.

The water is extremely acidic and could be affecting the bog and the lakeshore.

Starting this year. N1PSCO will stop the drainage from the ash ponds.

As a result there will be less flow to both aquifers.

Both aquifers could be depleted by the combined termination of the ash and seepage and continued dewatering.

i This paper is about the threat of the pumping to the lakeshore and the bog.

It provides background on the questions still unanswered as of March, 1980.

1.

How will sealing the ash ponds affect the Bog and the Lakeshore?

2.

Will the new NIPSCO pumping from the lower aquifer have adverse ef fects on the Bog and the Lakeshore?

3.

While in many locations both aquifers are well separated.

Both the lower and upper aquifer were recently found to be connected in a " window" under the Bowles Bog.

What impact idl* 16wer aqui-fer pumping have when this fact is considered?

4.

Ulcimately what risk is there to th= Bog and the Lakeshore from the continued pumping and construction at the Ba!.11y nuclear power plant?

5.

Will injection of water prevent damage to Lakestore vegetation?

The answer is clearly that we have ilttle or no idea of the consequences of the combined pumping from the two aquifers and termination of fly ash pond seepage.

Although the United States Geological Survey (USGS) is now commencing intensive studies of these new interactions; and the Park Service oeems to have extracted promises to protect the park should excess dewatering oc<:ur the consequences today are unknown.

The continuation of dowatering, even the remedial propostis of reinjecting the water and the ef fects of termination of the fly ash seo;: age could have substan-tial effects on the Indiana Dunes National Lakeshore ant the critical Cowles Bng.

Is it proper to proceed without further data?

s.,...

l-1.

THE PROBLEM i

Dewatering 1

1 The proposed dewatering of the Bailly Nuclear Power Plant construction site (Figures 1 and 2) remains unresolved after years of lawsuits, surveys, j

models, predictions and debates.

The dewatering issue may seem petty to those averse.to the more ominous threats of nuclear power, but the issue l

has proven to be a vital tool in delaying construction, in sensitizing 1

. local residents and authorities to the less obvious threats-of nuclear

'^

i.

power and in protecting the National Lakeshore which adjoins the site of the plant.

Even issues such as a proposed park expansion to include the NIPSCO Greenbelt between the plant and the park must consider the dewatering issue.

l j

Flv Ash Pond Seepage O.

NIPSCO presently operates two coal-fired generators at the Bailly site i

for which five ponds have been installed to collect fly-ash debris from j

the air filtration system.

Since full use of these ponds began in 1968,

^

ground water levels have risen fifteen feet under the ponds (which are about six feet in depth) and more than ten feet within the Lakeshore.

i This water is highly alkaline. (Appendix Figure 1)

Constant floo' ding i

nas affected over 750 acres, and has-substantially changed the ecology of that area.

Environmentalists are especially concerned about Cowles i

Bog National Natural Landmark, only one and a half miles from the Bailly Station.,

4 NIPSCO is presently constructing a nuclear power plant, called Bailly N-1.

Construction activities necessitate draining or cewatering the site.

The comoany has installed a slurry wall (Figure 3) around the construction i

site to prevent the seepage of. water into the area, and to prevent lower-ing of groundwater levels thtbughout the Lakeshore from dewatering activi-1 ties.

However, the amount of water pumped from within the excavation site as of December 15, 1977, exceeded the original amount of water estimated to be stored within the slurry wall by 7 to 14 times (Meyer & Tucci, 1979).

In addition, NIPSCO reports that the water level within the slurry wall-declined by only 8.5 feet, as compared to the predicted decline of 30 feet.

Obviously,.either the slurry wall is leaking or the conductivity of the

. underlying sand layers is higher than calculated and the lower aquifer is leaking to the~ upper aquifer, or both ef fects are combining.

NIPSCO was ordered to halt seepage from the fly-ash ponds in November, 1977, but work was to have commenced in-March -1980.

Meanwhile. dewatering acti-vities for Bailly construction continue.

The effect that dewatering will

)

have once seepage is stopped remains insufficiently resolved, while emer-gency measures to.reinject water into potentially affected park lands cculd

'be unsuitable.

According to the Park Service the proposal involves in-jecting' fresh water from Lake Michigan into depleted park lands via a l

" trickling filter recharge system".

Not only will such a trickling system

? continue.to disruot the natural' groundwater flow, but it will also change the'qualiev of water that naturally constitutes.the park stvundwater table.

-and consequently,;the variety of life within'the park. (NPS, 1977).

. Presently the Park Service seems more confiden'..of the remedy.

. * ~

i

.b'

%.f. -

q T

I

_...l gr.6 '

i I

/'

00NE ACHES si v f CNIG"

/'

l 8#

f

(_ _ ___. [ _ h

?

l

!~-

2 l

f.,], '.,p' I

f'

{

E

)

~ '. wNE.

~~

INDI ANA DUNES NATIONAL LAKESHORE f-

)__

~

(

g.

l

/

-~

h.

,a s iii, maicas i

....... ii.

f.,,..,,,...

~

i M

jf usamv i'dinium 5

............ 4. 1..

f.~~-

1 j

h k

1 -

.1...,

NORTHERN INDIANA 1

./ '

f BETiiLEHEM STEEL CORPORAT10N L

BURN $ HARBOR PLANT

' - - - - - - - - - - - " - - - - - - ". - - " - " - " " " - " " - " " "',' S E R V I C E kf

~

... ~

I Ykes 38prq49[pgp Q2 r.

{

COMPANY

~

g f3 F

U is

.e s.

gt'

~

~.-

v ll l..

~

er?'O'$5%%W'?@l J

.y u

t

'i INDIANA DUNES jl F

f

  1. ,s#

NATIONAL LAKEstt0RE p***f,#g-tous icus or or l

j even union; reann l_;

1. _.. _ _.. _ _ _ _fTE s

'a a

na nn.

n... i.

u.

n.u u r n < i a, r.. c : i..

r. i t.-

i m... i. n T n ' '..*....'....*. *

"m.m 2,..

>dit i'n

'a

~'

>'s'~r-FEFP '..a=*d.. e.'.....

.b

?QfWMjQ?Qfl*h.M;&.Nyl$%r (7

n;.

.'j

'j 1 h %i, N

' ' k It W y, h. &..

,' = ee

,,t'*,

.bY u

Y

,Wl., f,

.M

. ~fy.

. an). l N

J*

e.'d-

}{*

t,) f *a q; 3,. J9TL_2ar wr aPmiN Q' i *,t.h, i

6, si

?

a s y'I. y

.y-

.T 3

e.e j

)'se l

~

!. s e

t o

Y.

L.h

{

E,. N l' j

! fdW 31 A.I f ~ 4 W8.Pr Y..,.,thi.-m -y%r

~...

$@!M.h[I,g.sif - E,,)fh@.',

e

<v W

wlu,j}wk tW.H.'.I w,w / o m;

quv::.m

+

,, i.

s e.g.qq y.J w,bSh= /$qb:$

M,

h h, l

{

h3 L.'MFIMs?!9,b' Ek Mi 'II b =I Q

wg.;a.ew%,.'5

.h@(l)h h,,. i f

kI wnbe O

g

@arp w

~

R 7 :y d J.,! d !

f

'w"<j)h i@?;a <?pM:nSW I h '* l \\\\\\ b I

& :?p'f Sity.di?lri;YfMh[h:;y~,;~;5%

n?-WE f

QW%i'?:.M 3.$; '!

ql 1

y

.p

%.k

%[~ '~$s$:$i$

E%f<f.i-l

%' y.

>,-A.W ^,, <Qsm.tf )e g 1

,e,,h.:.v;

.n i

,,.,.f.

l

'.. e... em W s,.

.ssw:

f s;.o, n. :..

+.

i,t s.,ge, s.+,.,

.\\

T ml-~;.e ?? A g,.

l f...

,4..':

C....g i

, W.f p a iv

.. e.

k,k ' Wf!@5f' *;5

'.;gh??3%. '

.< ar. >. -

A Nh$bhhk'I'..

't kf Eff. 5ht+iY.b., '.hik.$

9$

q%*M.4p%g, J /g./,

f-T hF

..n%,? pg

.: 7. e.p;c% if (

D
.

k m u A...

  • ys& $y,p.

sf 1,

pcp

>S
95. lid'y,fp i F 3 '$l'

. l l

Wh, 4fs-9.Ulpsy*TU{5 kf.'i,f,'!

j.fM@@.fdi2.NNT@,h)

"". y; sa

\\

fm p m.p6lq.y Wp.'::.3,; 4I vh b',h.t u.

4',.. p'e?g..

I.

l 1,j - 'h[.$-1.pWdM ---~ "

~ M

,.., d f

  • e'l
g.s'

.y 'g.i.,r g ggf g.z. rc _g g m a g g ig N.

3 c

..g ce m p q m sg

~. Y a.a. it

, % 7.:

-11 gm4s

.t.*- L: qQ s?

.Q.

.w r

e:

EM MdEdj,h..I,i!&3 M M yffhpi!!}M i%$$?$h}$0

^

s.

.t

p[." -

1 t' $ r 4

.w

,%i' b

3 k.,.

f.

... 2.a.;.)..1.r.:./..,.'i :;.a a./;.,7 f fh k, /cg4 1 ath:r.:.hf.at T.i e;.M. y S.. N -

L. '

  1. . *".a

-J 4 *.

.ti I

.r.w:.:..',w, e ;;.s.aP" #*D b d#kh: d~~.IJ itJl:.% 4.aj '

y ?r.

c' s - 74r Figure 2.

December 1979 view of the Bailly' site. '

(photo courtesy of Chesterton Tribune)

< = c

'r EA#

e

. ) UY w

?

Yg t

9 l

9 36, tj EIPLANail0N J

i;

$3,_

g.4, Coal-fefed electaec.

  • ,0 Jgg Demet ges.e f a te t s q :-%:.

5' 4

-g Sheet siisng Iivffy call. Avefage 1

elevation of too.

601 feet.

- J 9hlacavateen centeur AOpf0 strate elevaleen, en feet Boundsfy el estavater,n 620 Accrossmate elevatices.,

in feet Datum is mean ses tenet 1

g Pump l

l 4

S w

see t

Ihtsknett of gluffy call e,

nei

t. icaie L

/

N Base lf0F Escavatter Plan. 40fthern Intliana Ponies sofvice cossany, esi8erto=n.

inc.. er l

Safgent and Lundy Figure 3.

Slurry wall at Bailly Plan:

~

fron Meyer & Tucci, 13.

l

5-Predictions Unconvincing These three areas of concern--fly-ash seepage, potential construction dewatering effects, and water injection--are so interrelated that pre-dictions by both the USGS and the National Parks Service (NPS) remain j

unconvincing.

When Assistant Secretary Reed first reviewed the proposal for Bail'y N-1 in June of 1977, he commented: "While I seriously doubt the wisdom of selecting this site for construction of a nuclear power plant, I have decided not to seek a reversal at this time..."(Hendrikson, 1979).

In a published statement and testimony before the Atomic Energy Commission (now the Nuclear Regulatory Commission), the National Parks Service and the Department of the Interior, he cited the following specific points:

Acid rain formation from the mixing of the coo:.ing tower plume with the smoke from existing fossil fuel plants; this could produce ' acid rain.'

Salt deposition from the cooling tower drift as it may effect ponds, bogs and vegetation of the lakeshore.

The aesthetic int usion of the call cooling tower.

Possible detrimental effects of ground dewatering, which can occur.

Possible interference with the patterns of visitor use at the lakeshore.

The precedent of locating a nuclear plant adjacent to a national park property because it provides a desired low population density location.

s t

The dewatering events alone since then may lead us to doubt further the wisdom of this NPS decision not to intervene to protect the parklands.

II.

THE BOG After more than fifty years of citizens' efforts to preserve the unique character of the Indiana Dunes, Congress authorized creation of the Indiana Dunes National Lakeshore (INDL) on November 5.1966 (P.L.89-761, 80 etat. 1309, 16 U.S.C. 460u).

The park was formally established in 1972.1 Located at the southern tip of Lake Michigan. INDL sits at the edge of one of the nation's most heavily industrialized regions.

Cowles Bog Wetland Complex was established in 1965 as a national landmark and is within the park.

Renowned to possess some of the area's most diverse and complex natural conditions, the bog, which some call a " wetland com-plex, was named after Dr. Henry Chandler Cowles (1869-1939) of the Uni-versity of Chicago, a pioneer American plant ecologist who extensively catalogued and studied the shoreline's complex ecology.

This 56-nc-e wetland complex included " marsh, bog, wet meadow, swamp, prairie and sand dunes in various stages of succession". !

l l

!=

Primary Park Service objectives include " preserving, for educational, inspirational and recreational use, areas of scenic, scientific and historic interest and recreational value." J j

Naturally diverse biologic communities will be managed to permit evolutionary forces to prevail, uninterrupted, in a self-sustaining, self-perpetuating mode.

It is the funda-ments1 resource management philosophy of the NPS that nat-ural forces shall be preeminent in shaping the character of natural biological systems and physiographic features.

The intent and purpose of park natural resources management and protection programs are to restore and ma'1tain environmental conditions such that natural forces are predominant.4 Lyon said that the Cowles Bog Wetland Complex includes the area histor-ically known as Cowles Tamarack Swamp and the Mineral Springs " quaking bog" (Lyon, 1927).

Lyon clearly considered that the Wetland Complex contained at least three wetland units: the Tamarack Swamp, the quaking bog, and the Great Subdunal Marsh where presently a Bethlehen. Steel plant and NIPSCO coal plants operate. f-These wetlands represent a continuum in terms o' vegetation, water regime.

water chemistry, and degree of soil compositior; they are generally referred to by peatland ecologists as bog or fea, although they would include sedge meadows, prairies, cypress heads, swamp carrs, etc.E The term " fen" is a newcomer to the ecological vocabulary of this country.

It was apparently introduced by Sjors (1950) ard appears in American literature with increasing frequency.

At present, both the Europeans and Canadians have developed rather rigid definitions of bog and fen based on water chemistry, water regime, soils and vegetation.

The term

" bog" is limited to peatlands with acid pH, (generally less than 4.5) and extemely low nutrient content in the surface layers, with the primary source of water from precipitation.

Bog floral composition is extremely specialized (an area of " low productivity), dominated by Sphagnum moss (which acidifies its environment), accompanied by leatherleaf, pitcher plants, sundew, blueberries, cranberries, tamarack or larch trees.

A fen is also a peatland area, the basic difference arising from the way water enters the system.

Instead of resulting =ainly from precipitation, the water seeps up from the groundwater, is extremely rich in minerals and nutrients, and sustains a heterogeneous floral community.

The most com=on plants are cattails and sedges.

Most of Cowles Bog Wetland Complex resembles a fen, but has dist' ace characteristics of bog, marsh, and swamp in various locations.

Dr. hendrikson's diagram of a cross-section of the landmark (F.gure 4) illustrates the degree of change.

i

i III.

FLY-ASH POND SEEPAGE i

In 1966-67, five fly-ash ponds to serve the coal-fired generating Units 7 and 8 were placed in operation. 7 Fly-ash _is a substance resembling clay dust, both in physical size and chemical composition.

Approximately 5,* of coal by weight becomes fly-ash when burned.

Fly-ash contains sulphur, boron and several trace elements including cadmium, arsenic, selenium, manganese, and zinc.

Groundwater Elevated 4

The effect of these five ponds, which are designed to collect fly-ash, 1

let it settle to sediment where periodically it is dredged and used elsewhere for landfill and seeded to rye,has been to artificially elevate the groundwater table level in National.Lakeshore lands by as much as three feet.8 Approximately 1.8 to 2 million gallons per day of I

water seep into the ground through the porous sides and bottoms of che' j

ash-settling basins.

The ash-basin seepage has created a,mostly under-ground water mound which slopes in all directions away from the seepage 4

source.1 Water levels in the immediate vicinity of the ash-settling 4

basins are between five and ten feet above water levels of the flooded marshes within che Nat,ional Lakeshnre (Appendix Figure 1), 10 thereby a

artificially elevating the surrounding water table level.

Interduna? marshes have remained flooded constantly since 1969.

Accord-ing to the National Parks Service (1977), flooding has caused "unaccept-able alterations in the natural character and functioning.of park wetlands. ".??

It has eliminated the previously established marsh vegetation, and

-reached such high levels that ash and other trees were killed in areas around interdunal ponds.20 Water levels within these interdunal ponds now vary little seasonally.

Presently these ponds are developing a flora and fauna common to ponded areas. J 4-Serious Impact on Dune Ecology i

i This artificial elevation in the groundwater table has had serious impart not only on the dune ecology, but also upon the natural ground water flow.

The ash basin seepage has created a water mound around the ponds which slo;.es 7

in all directions away from the seepage source.fi Hendrikson and Wilcox (1979) document that there is a positive hydrclogic pressure within Cowles Bog underlying the peat mat.26 Instead of Jeeping downward into the ground, water circulates upward, because the sandy soil-is already intensely satur-ated and is also_ highly porous.

Ground water movement would normally flow towards Lake Michigan, on top of a clay shelf which acts as a confining layer'underneath the peat and marl of the marsh lands. ( Thus, ash basin flooding has reversed the normal physiologic groundwater flow.

b l

As a result of such flooding, the NPS ordered NIPSCO to stop ash basin seepage.

The NPS began to recognize the magnitude of the effects at an interagency meeting convened at the Indiana Dunes to consider the po-tential impacts of the Bailly Plant.17 NIPSCO, after delay, threat of litigation and protracted negotiation, formally agreed in February of 1978 to stop the seepage.

Because a water treatment facility is necessary and NIPSCO had just been granted a permit for this, the company was given 32 months to stop the seepage.IS Sealing of the ash ponds was scheduled to begin in March, 1980;but had not begun on March 11, 1980.

IV. DEWATERINC HISTORY The corporation's pumping history, associated mainly with construction dewatering, has been complex.

Upon approval of the construction permit (May 2, 1974), NIPSCO installed a slurry wall around the construction site to prevent water from seeping into the pit.

The wall extends about 40 feet below the surface, to the clay layer.

In addition, sheet pile has been installed around the deeper reactor building and auxiliary building exca-vation to reduce seepage from the unconfined or upper aquifer into the site.

The present dewatering system consists of five sump wells, two free '1owing drains and a shallow wellpoint system.12 Although the corporation keeps no record of the race or volume of water pumped at a given well, they have in-stalled 25 observation wells for monitoring purposes.

Their pumping pro-cedure consists simpl+ of maintaining water levels within a few feet of tho top of the well screen.

Pumping at a given well is virtually continuous, although breakdowns have caused downtimes of unspecified length.20 Reco rdt of depth are not available for any of the sump wells.21 The anticipated sustained pu= ping rate required to control seepage into the radwaste area (the southern portion of the' construction site) is estimated to be 700 gallons per minute (gpm).!S When excavation proceeded to +10 (or 30 feet below ground level) groundwater levels were maintained at approxi-mately El. +8 inside the slurry wall by continuous operation of the five

. sump "$11s, which have a combined discharge rate of 250-300 gpm.

In a second phase of construction it will be necessary to lower the water to an elevation of -3 feet, to proceed with construction.

The entire discharge rate from the free-flowing drains is 500 gpm. 2 With the combined use of drains and sump wells, NIPSCO expec.s to control groundwater levels within the slurry wall.

V. HYDROLOGIC STUDIES In October of 1978, a four-year study of the entire Indiana Dunes Lakeshore was initiated by the United States Geological Survey in order to investigate the hydrologic and chemical relations between surface waters in the Great Marsh area and shallow groundwater systems immediately unceclying the marsh.I!

Twenty-five observation wells have been installed and are monitored on a continuous weekly basis.

Selected hydrographs indicate a close correlation between water level fluctuations among the observation wells, i.e., the rising and falling trends in one well are observable in the other wells.

SIPSCO is responsible for monitorir.g its own wells, while USGS periodically checks the wells and measurements to ensure NIPSCO's accuracy.

=

-.. ~

USGS monitoring will continue at least until fly-ash pond seepage ceases and construction of the power plant is complete.!6 However, the National Park Service has recently become concerned about i

N1PSCO's monitoring and demanded " independent" conitoring.

NPS has been concerned as well about NRC and NIPSCO's failure to involve the Park Service in monitoring programs.

The USGS and the NPS have developed their own plans as well.2C The area underlying the Great Marsh and Dunes Lakeshore has been found to contain four distinct layers, mapped by Rosenshein and Hunn (1968).

According to their report, Unit 3 is sand and gravel that locally con-tains thick clay beds and is called the lower or confined aquifer; Unit 2 is chiefly clay, which hydrologically confines most but not all of Unit 3; and Unit 1 is chiefly sand called the upper aquifer.27 In order to determine the extent of groundwater flow both laterally between and vertically through the layers, and throughout the over-all area, a model (Trescott, 1975) was set up to simulate groundwater flow.

Unit 2 (clay) was found to have such low lateral hydrologic conductivity that horizontal flow is negligible.f3 And the clay's Jou vertical conductivity makes it a confining layer between the two sandy, porous layers.

However, later studies showed leakage under Cowles Bog, at the southern third of the excavation and elsewhere.

After calibration, the model was used to: (a) investigate the effect of termination of fly-ash pond seepage (an immediate draudown of fifteen feet underneath the ponds, with up to three feet drawdown in the INDL area), (b) establish _how much water the slurry wall could conduct (approximately 1.8 to 2 millions gals / day), and (c) establish the effect of construction dewatering on groundwater levels.2d The model was calibrated on the basis of water levels from October 26, 1976, assuming steady-state conditions for that time, although Meyer &

Tucci (1979) say that steady-state conditions do not prevail within the study area.JO Water levels in NIPSCO wells #14-20 have changed as muen as 6.6 feet since October, 1973.

Obviously, one cannot make steady-state assumptions based on one day's worth of information.

Water levels-on October 26, 1976, represent the combined interaction of many factors.

Accural rates of groundwater discharge to Lake Michigan and seepage to Unic 1 from the fly-ash ponds could have been higher or lower than those indicated by the calibrated model, but for purposes of the model. USGS chose to have those values represent the groundwater system.J.?

VI.

STUDY OF THE AOUIFER Levels in a confined aquifer are measured by corresponding pressures.

In order to determine the hydtostatic pressures in the confined aquifer (Unit 3), six meters were installed between June 23 and June 30, 1976 (see Figure 12).42 Pressure levels are submitted. weekly to USGS.5J.

According to the USGS pressure levels in the excavation are about at level +15 or 5 feet above the excavation bottom in Phase I of con In Phase 2 of deeper construction the level would be at above the bottom--thus pumping from the pressurized aquifer must be done

+5 or seven feet since pressure levels illustrate levels sought by water.

Changes in groundwater levels, and consequently in flow directions and rates have been found to be caused by (1) fluctuations in the state of Lake Michigan, (2) fluctuations in the water level maintained in the

' fly-ash ponds, (3) a change in the distribution or rates of pumping within and near the study area, and (4) changes resulting from natural variations in recharge to Unit from Unit 1 and evapotranspiration.J41, including precipitation, discharge i'

The USGS prepared maps showing the change in water levels in Unit 1 for the various times since the start of dewatering.

k'ater levels have risen in most site and in the inner vicinity of the site.of the area whe.a data are availab It is evident that within the slurry wall. pumping has succeeded in controlling the water Jevel Potentiometric studies have verified the inter-action of at least four factors affecting groundwater levels, but essential question concerning the effect of dewatering on park lands the remains unanswered.

It is important to note that changes of as little as six inches over a sustained period of time will cause serious environ-mental change.JE Serious questions still remain as to the usefulness of these reports USGS identified several assumptions to be made, then constructed sixtee The different models to show the extent n

of dewatering.

based on the potentiometric studies discussed above. Those models were sixteen different hypothetical conclusions.26 Thus, there remain Any excessive drawdown of the park's groundwater resources has thus far been masked by changes in the ash basin seepage rate.

model testing acco=plished thus far predicted devatering impacts wouldUSGS hydrolo through the porous sandy substrate. reach into the Nacional Lakeshore becsu construction site at Dewatering of the Bailly Station could alter the hydrological regime within the lakeshore, perhaps eve the wetlands surrounding Cowles Bog, and in all probability, the bog itself.J?

According to the National Parks Service, "we have a ball park understanding of the likelihood of dewatering (even a playing field under-standing) but not a precise prediction.25

.. ' t i

New Data Changes Studv Conclusions Even the extensive Meyer and Tucci study completed in 1979 did not cover important new material.

Late in 1979 NIPSCO realized that they needed to pump from the lower aquifer if the heavy lower pressure were not to cause " boils" in the excavation.

This new pumping could adversely affect the national lakeshore by drawing water,from a more stable aquifer.

The USGS is now modelling the new pumping and will have a report in about six months.

Concurrently the USGS followed up a report issued in late 1979 by Hendrickson and Wilcox of the National Park Service and discovered in early 1980 that the confining layer of clay between the upper and lower aquifer had a window in it.

The window occurred just under the Cowles Bog and presumably could magnify the effect on the Bog of any drawdown from the lower confined aquifer.

The USGS is now studying the informa-tion to determine what effect the new pumping from the lower aquifer l

will have on the Bog with this new connection between the aquifers.

l l

The extensive Meyer and Tucci report did model the change in groundwater t

levels as they were affected by the ash pond seepage.

The report, however, did not consider the effect of termination of ash pond seepage combined with dewatering.

The Geological Survey plans to model this effect in the future.

1 NIPSCO and the Park Service had always considered that construction would be completed and dewatering terminated long before the ash ponds were sealed.

If this were true then the ash pond seepage could well provide j

the,cxtra water needed to keep the aquifer at needed levels while devater-ing occurred.

However, with the long delays in construction of the plant and the commencement of ash pond sealing in 1980 it is evidait that the ash ponds will be long sealed and dewatering may be continuing for years.

Drawdown will then inevitably occur.

USGS now plans to model this effect as well.

4 Even completion of the plant may not terminate the dewatering problem.

It is still unclear that pumping will cease upon the backfilling of the exca-vation.

VII.

PROPOSED RECRARCE SYSTEM Yn the event that dewatering af fects the park lands, NIPSCO (under NRC supervision) will mitigate that by recharging water into the ground on its side of the boundary by a trickling filter recharge system, so that water. pumped at the nuclear site is not. drawn from park' lands.3; According,to NIPSCO:

"Croundwater levels in existing observation wells will be used to prepare a west-to-cast profile of the groundwater mound (a

. bulge in the groundwater level) created by the trickling filter recharge system...during a period of adjustment, the rate and i

f requency of applica tion will be -varied and the resulting ground -

l wa*.er profiles across the mound will be evaluated.

- la -

In this manner,the optimum rate and frequency of application for stability of groundwater levels in the unconfined aquifer will be determined.

I Since the frequency and rate of application may vary seasonally, the height of the groundwater mound cannot be predicted.

The height of the mound vill be maintained at the lowest elevation necessary to prevent further expansion or deepening of the cone of depression in the direction of interdunal ponds.

Weekly potentionmetric surface maps and groundwater mound profiles will be the basis for control.

The trickling filter recharge system will be operated and controlled so that the resultant groundwater mound does not extend offsite." 40 NIPSCO agreed to the NRC position of a one-foot " drawdown at the property line attributable to construction dewatering as the criterion for imple-mentation of mitigation measures during the spring, sum =er and fall seasons."i!A two foot drawdown at the properly line would be used as winter criterion (December through March).

According to NIPSCO:

" Groundwater levels normally decline during these months owing to a lack of recharge to the unconfined aquifer...

such a minimal increase in the draudown during the wintec months will have a negligible effect because vegetation-is dormant and the interdunal ponds are frozen during those months." 4.5 On September 19, 1978, the NRC found NIPSCO's water monitoring system acceptable. 4J USGS/NPS Exoress Reservations Both the USGS and the National Park Service, however, expressed reservatione.

about the plan.

In October, 1979 they asked for independent monitoring, complaining that they were not asked for comments on the NIPSCO plan for monitoring and mitigating effects of dewatering.

They also reserved the right to later oppose the NIPSCO plan.

Superintendent L'hitehouse called this an " emerging" NPS position.fi As a result the Geological Survey and the Park Service prepared their own plan for monitoring.

The plan askud for "immediate communication from NIPSCO

{

to NPS" whenever significant changing pumping rates occurred.

NPS also asked 1

for more frequent collection of data when the effects of the fly ash pond had terminated since this presented more danger to the National Park.

The NPS and USGS plan also created an " alert" system.

Often data from wells, even that immediately " communicated from NIPSCO to NPS" must be processed by computer before indications of drawdown can be shown.

The plan recog-nizes that certain levels of drawdown snuuld. require f:. mediate action, l

=

13 -

Although the plan does not describe the action to be taL:n, presumably both parties meant either that devatering of the construction site would j

be halted or that injection would be increased.

One key point mentioned in the USGS/NPS papers concerns the accuracy of the plan.

Both parties conceded enat water level changes can not be separated into individual components.

They point to " variation in natural recharge to and discharge from the aquifer, changes in the level of Lake Michigan, termination of fly-ash-pond seepage, industrial pumping, and construction devatering" as simultaneously influencing the upper aquifer.45 The plan is also based on the earlier data from the Meyer and Tucci report.

According to the plan "the water level declines in unit 3 (the lower aquifer) will not be suffici nt to dewater any portion of that aquif er". 4C Never data, however, described above, tends to undercut that assumption of the USGS/NPS plan.

Inieeted k*ater is Different Water Although the trickling filter recharge system is planned to control water level at the property boundaries, such a system will not insure the quality of the water flowing into the parklands. Aquifer water differs from other water in its long period of confinement, types of nutrients, and other characteristics.

Yet no NPS, USGS or NIPSCO report, program or study currently recognizes this issue of nutrient rich groundwater which supports both the diversity of aquatic life and the unique species that presently inhabit the bog.

Replenishing depleted groundwater sources with lake water, as proposed by NIPSCO, would alter the quality or water now in the park lands, and could continue to alter the natural flow of groundwater towards Lake Michigan.

l

- 14 VII'I.. CONCLUSION The Indiana Dunes National Lakeshore and the Cowles Bog are fragile and highly dependent upon the aquifer as a supply of water.

It is clear that the construction and perhaps the operation of the Bailly Nuclear Power Plant will affect that aquifer.

At this time we know that NIPSCO must pump from both the upper and lower aquifers, that the ash-pond seepage will be j

halted long before pumping ceases and that there is a potential.for signi-ficant effects from drawdown of the aquifer by these actions.

Even more critical is the recent discovery of a " window" under the Cowles Bog which could communicate changes in the confined aquifer more directly to the Cowles Bog.

And no one is sure what the effect might be of water injected to make up for losses since it has different composition than existing groundwater.

Studies will not be completed on sone of these effects for almost six months.

We do not know the effect of the sealing of the ash-ponds?

We do not know the adverre effects of NIPSCO pumping from the lower aquifer?

We do not know the extent of the risk to the National Lakeshore from the continued dewatering at the Bailly site?

Under such circumstances it would be inappropriate to proceed with construction of the Bailly nuclear power plant.

The National Lakeshore is too important a resource to be subject to further damage.

Changes in water level of as little as six inches could cause serious environmental damage.

Such a critical para-meter counsels extreme caution.

l The Federation recommends:

~

1.

That further pumping be halted until a thorough dewatering 1

study is completed.

2.

That USGS continue its studies over the next six months insuring that they are comprehensive and recognize all revelant variables.

'3.

That a competent team be assembled to study the effect of injection of new water to offset losses to the aquifer and that the team recommend sound methods of injection to satisfy bo.th quantity and quality requirements if these can be achieved.

4.

That baseline data be rigorously scrutinized to assure

-that it represents the steady state condition of the aquifer ~and a protected natural state of the Cowles Bog and the National Lakeshore.

5.

A-strengthened role for the National Park Service in protecting the Park fro = the danger of aquifer drawdown-and change in vegetation and other qualities of the park.

The Park fervice should have authority to halt devatering and should approve.all dewatering and injection programs in advance.

+

!.;otnot:3

1) Ha:ional Park Service. " Technical Repor:: Indiana Dunes National Lakeshore - Bailly Genera:ing S::: ion. " (Sept. 30, 1977.) p.1.

hereinafter " Technical Repor:".

2). Ibid; p.6.

i

3) Op. Cit:
p. S.
4) Q. cit:
p. 6.

S)

Car:er, Virginia and S:c:tlemeyer, Rober:., "Scology of Coules Bog We: land Complea; Indiana :unes National Lakeshore Special Study. " (Jan. 30, 1978) p. 23.

6) Ibid: p. 23 7)

" Technical Report. " p. S.

6)

" cchnical Report. " p. 28.

9) Ibid: p. 10.
10) Q. Cit: p. 10.
11) Q. Cit; p. 2
12) Q. Cit; p. 13
13) Q. Cit; p. 13 14]

Op_. Ci ; p. 10 li:

" Briefing Paper. " p.

4.

1C)

~ bid: p. 8

7) " Technical Repor:. " p. 14.
i) I cm #4, USGS Survey S:udy of NI?SCO Ash Pond Seepage and Site Deuatering Activities. Plans to Correc: Adverse Effec:a on the lakeshore. (3riefing a:atement prepared by Na:ional Park Servi;s for Director k'nalen's 1979 visi:) Hereinafter "I:em N4".

"SupplementarlInforma: ion, Hydrogeologic Evalua: ion of Construc: ion 19)

Deua:ering." -(Aug. 27, 1979.1

p. 9.
20) Miyer and Tucci, " Effec:s of Seepage from Fly-Ash Se:: ling Ponds and Cons: rue: ion Deva:ering on Ground-Water Levels in the Coules Unit, IND*, Indiana."

(Jan. 1979.)

p. 49.
21) Le::ers from Mr. Sohn (NI?S:0, Manager, Nuclear 5:aff) :o Mr. Ronald Saliard (NRC, Enviror. ment Pro:ection Branch #1. (July 2r 1976. ) p.

1.

Foo:no:33: (cont.)

?ag3 2.

.g

22) Le:ter from Schn (NI?SCO) :o Eallard (NEC). (July 20, 1978.) p. 7 23)

" Technical Repor:."

p. 10.
24) Le::er frcm Gillies (USGS) :o Hartman (Dune Acres Tcun Board).

(July 12, :979.)

25) Ibid;
26) Correspondance and c::cchnents, James R. Vni:ehouse, Superin:endent, Indiana Dunes Nabicnal Lakeshore :) Nucie:r Regula: cry Comission, (1 Oc:ober 1979.)
27) Meyer and Tucci,
p. 3.
28) Toid;
p. S3.
29) Cp. Ci:;
p. S8.
30) Op. Cit;
p. S3.
31) Op. Cit;
p. 49.
32) Letter from Bohn (NI?SCO) :o Ecliard (NRC). (July 20, 1978. )
p. 11.
33) Tcid;. p. 12.
34) Meyer and Tucci, p. 37.

35)

" Technical Report. "

p. 23.

36)

"Icem M4.'

37)

":echnical Repor:."

p. 22.

38)

" Item M4. "

39)

"::em M4."

40) :.e::er from 5chn (NI?SCO) to Eallard (NRC). (July 20, 1978.)
p. 9.

41)

Toid;

p. 17.

42)

"::em M4. "

43) Let:er from Ballard (NRC) :c NI?SCO, A::n: Mr. Lyle. (Sep:. 19, 1978.)
44) Co"~;unication from Vni:ehause (N?S) :o NRC, Oc:cher 4, 1979.

45)* _CSGS/N?S plan for de:erming deu::cring of :he Indiana Dunes N :ional Lakeshcre adjacent :o N!?SCO 5: illy gener::ing station (c::cchmen:

c Vnicehouse Co msnic::icn, Ibid.: pp. 5-C.
46) Toid; ~ p. 1.

BIBLICCRAFHI Car:er, Virginia and S:ottlemeyer, Ecbert.

" Ecology of Coules Bog W.t: land Comple:; Indiana D.tnes National Lakeshore S:udy. "

(dan. 30, 1978).

Dep:r:-:en: of Interior / NIPSCO Agreement.

(Feb.

7, 1978).

Hendrickson, William.

" Briefing Paper, Indiana Dunes National Lakeshore Prcycsed Acquisition of Area II-A."

(Feb. 1979).

Hendrickson, William and Wilcoa, David.

"Relationshio Betueen Some Physical. IrG ar::'cc and the Vege:a: ion Found in Coul'es Bog N::icn:2 Nc: ural Land : ark, Indiana. " (Nov. 1979).

Linisey, Sch :etz and Nichots.

" Natural Areas in Indiana and Their Preser::ction. " Dep t. cf Eiclogic Sciences, ?urdue University.

(April 1969).

Meyer and Zucci (USGS).

" Effec:e of Seepage fro : ?!y Ash Set: ling Ponds and Cor.s: rue:icn Deva:ering on Grouni.:::er Levels at :he Coules Uni:, Indiana Dunes Mc:ional Dakeshore. "

(Jan. 1979).

N::icr.:t ?:rk Service.

"Nc:ional Lakeshore Management ?lan" and "Wes: Uni: Pr:posals. " (Dec. 1979).

Naticr.at Park Service.

" Technical Reper:: Indiana Dunes National Lakeshore 3ailly Generating Sta:icn. "

(Sept. 30, 1977).

1 l

i 1

4

N/;

s

.N Y

  • s

.~. \\

.r

\\

n m

m C9

\\

q

=c Z

6,9 V1

= -

> r*

=m

~~~~

a*

a o

e,

  • g n l

., e

\\

.. ". /

~

=-g s

2. w s,.'.

=>

s

,e,.

.a

  • e.as

=

6.., -

L =-

C e

ar

=

..I E 9

9

.6

-5.-

DD

=

5 f

(%.

t t..-

2 1

O 8

=

s.

a

-a m

D

\\,

Z

  • r a
j. kg*.

s

..e*

^-

,g

'. Q e

A k

(,

'- *i:

v.

s i

l,

-t 4

e-z g

1 w

t5 i

+

--t Z

C C

Z a' r 5-L. ~..I

~ C w

m a -.

m

=

f.

a

'e*t C.

'3

\\

- I

, [! '

O

.m x

_ f..*..* r t,

P.

2 7

, =, '

7

==9 4

_~. m M

  • c

(

'".,.,4-O U$

5

,; z, C

=-.

r.

p

=

t z.

M 2

~..

..e 2"

v M

T

?

g u

l

-,a

~

1 1

=

7

.o.

\\

Appendix-Tigure 1,

. g

{F Ce:line in water levels fro.

T p7 :

I 1

  • d f.
ertinatien cf fly-ash se:-

?'*

3 t'ing ?cnc seepage. F;:=

l-

  • 1h ;

Feyer i Tue:1.

fre..:

r I,.

1...; "

S.

See are f.r_v F i v-A,.. %.T 1..

1:1; 7 Pr es an Cce.tru...n t 1.

""*'*i*f-( L'505. Iv?5'-,,..

e O

e h4

=

=.m eny

o APPENDIX 2 L' hat's Happening on the Bailly Nuclear Power Plant?

e 1.

About one per cent of the plant has been completed, basically an exca-vation near the Indiana Dunes National Lakeshore.

2.

The construction permit issued for the Bailly plant in 1974 expired on September 1, 1979.

A number of citizen groups, citizens, labor union-locals and others are opposing the' Extension of the permit by the Nuclear Regulatory Commission (NRC) beyond September 1.

Under federal law the permit can be extended if the power company (NIPSCO) shows " good cause" to the NRC.

There must be a hearing if any interested party asks for a hearing.

The opponents have requested a hearing but NIPSCO and to the staff of the NRC have opposed their actions asserting that some extent the parties do n: t have standing.

Each of the interested parties has been asked to descrits the contentions they will make if there is a hearing.

In mid-March the Atomic Safety and Licensing Board of the NRC (ASLB) held a pre-hearing ccnference to discuss these contentions.

At this time, the parties are awaiting the decision of the ASLB.

3.

A number of groups and citizens have long raised the issue that the sub-stitution of short pilings as a foundation for the Bailly plant required a hearing in front of the NRC to determine if design is adequate.

Accord-ing to these groups the short pilings would not reach to bedrock and the originial construction permit was based upon the plant being fully supported on bedrock.

The NRC rejected the group's contention that the staff was wrong in denying the group a hearing.

That decision is now being appealed to the D. C. Circuit Courts.

4.

The State of I.~.11nois has asked that the NRC halt the construction of the Bailly plant because of its proximity to a major urban area. The Cocmission will rule on this as a petition that NIPSCO "show cause" why a construction permit should nat be altered.

The NRC will decide if a hearing is required.

-