ML20038B168
| ML20038B168 | |
| Person / Time | |
|---|---|
| Site: | Bailly |
| Issue date: | 11/18/1981 |
| From: | CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| To: | |
| Shared Package | |
| ML20038B162 | List: |
| References | |
| NUDOCS 8111240795 | |
| Download: ML20038B168 (10) | |
Text
O REPORT ON THE RESOLUTION OF ALL CONSTRUCTION ACTIVITIES UNDERTAKEN AT THE BAILLY SITE FOR THE CONSTRUCTION OF BAILLY GENERATING STATION NUCLEAR-1 FOR NORTHERN INDIANA PUBLIC SERVICE COMPANY i
I l
l l
l t
l October 8, 1981 Revised November 18, 1981 l
l 8111240795 811119 PDR ADOCK 05000367 A
PDR l
a
4 TABLE OF CONTENTS Page INTRODUCTION 1
EXCAVATION 2
SLURRY WALL 3
SHEET PILING 3
H-PILES 3
SUMPS AND WELLS 3
TEST WELL AND DRAINS 4
.l WELL POINTS 4
OBSERVATION WELLS 4
METEOROLOGICAL TOWER AND INSTRUMENT BUILDING ~.
4 CONSTRUCTION BUILDINGS 5
i The Nuclear Staff Office Building 5
The Bailly N-1 Construction Warehouse 6
The Bailly N-1 Civil Test Lab 6
,i The Sewage Treatment Plant 6
34,500 VOLT CONSTRUCTION LINE 7
i SLAGGED LAYDOWN AREA AND RAILROAD SPUR 8
i BAILLY N-1 EQUIPMENT 8
r I
l l
l l
l l
l l
-i-l t
INTRODUCTION 1
The site on which Northern Indiana Public Service Company's (NIPSCO) Bailly Generating Station, Nuclear-1 (Bailly N-1) was
~
to be constructed was purchased in 1932 for the specific purpose of constructing electrical generating facilities.
The site presently consists of approximately 350 acres and is generally "L"
shaped.
Site development began in 1959 and Unit #7 (coal-fired, 194 MWe) was placed in commercial operation in 1962.
A second coal-fired unit, Unit #8 ( 4 2 2 MWe ), and a combustion turbine (Unit #10, 33 MWe) became operational at the site in 1968.
There is a large coal storage pile on the western side 1
of the site.
Ash ponds associated with the operation of coal-fired Units #7 and #8 are located along the east-west leg of the site.
Support buildings and transmission lines for the fossil units are located throughout the site and the Dune Acres Substation is located at the extreme southeast corner of the site.
The excavation for Bailly N-1 is located between the existing fossil units on the east and the coal storage pile on the west, Lake Michigan on the north and Bethlehem Steel Co. on the south.
That portion of the site was cleared and graded to elevation approximately +40' when the site was originally developeo in 1959.
The following report identifies the site related construction
..___ activities carried out by NIPSCO associated with the construc-tion of Bailly N-1 and NIPSCO's plan for the disposition of each such item.
_1_
EXCAVATION The excavation,*hich has been completed down to approximately elevation +8' station datum, will be backfilled to an elevation of approximately +40' station datum which was the approximate grade elevation of the area prior to commencement of excavating work.
The materials to be used for backfilling the excavation may include any or all of the following:
(1)
Material removed from the excavation.
(2)
Sand presently located on the Bailly Site.
No fill material will be taken from the area of the Bailly Site known as the " Green Belt."
(3)
Sand of the type generally found in the area surrounding the Bailly Site, including sand dredged from Lake Michigan.
(4)
Other clean inorganic fill material of a character such as to not produce appreciable differences in hydrologic conductivity or groundwater quality from the material originally removed from the excavation.
The work associated with backfilling the excavation will commence promptly upon receipt of necessary approvals of this proposal, and weather permitting, will take approximately 120 days to complete.
However, if the dredging option is elected, actual dredging operations will not begin until the summer of 1982. )
SLURRY WALL The slurry wall originally authorized by Amendment #1 to the Bailly N-1 construction permit consists of a slurry wall and sheet piling which form the perimeter of the excavation i
for the main building complex.
The slurry wall and sheet piling will be left in place.
SHEET PILING All sheet piling within the excavation except that used as a portion of the perimeter of the excavation will be removed, if practicable.
H-PILES The H-Piles presently installed in the excavation will be cut off to approximately
+8' elevation and left in place and covered over when the excavation is backfilled.
l l
SUMPS AND WELLS Six (6) sumps with dewatering pumps were located within the 1
excavation.
The pumps have been removed and the casings will be l
l left'in place and covered oveg_when the excavation is backf,iLled.
l l l
I 1
I L
TEST WELL AND DRAINS One (1) test well and two (2 ) drains are' located within the excavation and will be left in place.and covered over when the excavation is backfilled.
WELL POINTS All of the well points within the excavation along with their associated headers will be removed, if practicable, prior to backfilling the excavation.
OBSERVATION WELLS Forty-nine (49) groundwater observation monitoring wells have been installed by NIPSCO on NIPSCO property including six (6) pore pressure transducers.
The groundwater observation monitoring wells, all of which are located outside the excava-tion, will be capped and left in place. -The pore pressure transducers, all of which are located within the excavation, will be left in place and covered over when the excavation is backfilled.
METEOROLOGICAL TOWER AND INSTRUMENT BUILDING The meteorological tower and instrument building initially installed to collect meteorological data for Bailly N-1 will-be removed.
CONSTRUCTION BUILDINGS During the initial phare of Bailly N-1 construction, the following facilities were built to support the anticipated construction activities:
The Nuclear Staff Office Building.
The Bailly N-1 Construction Warehouse.
The Bailly N-1 Civil Test 5ab.
All of these facilities are located on the'Bailly N-1 site which is also the site of NIPSCO's existing fossil Units #7, #8 and
- 10.
The present and proposed future use of each of these structures is discussed below.
The Nuclear Staff Office Building The Nuclear Staff Office Building is a two-story metal frame structure, 60' x 160' located approximately 350' west of the east property line of the northern section of the "L"
shaped site and 800 feet south of the Unit #7 turbine room.
This building I
was constructed in 1975 to provide of fit-s<; ace and record storage c.
facilities for NIPSCO's Nuclear Staff and the Bailly N-1 Construc-tion Manager.
Various other departments within NIPSCO are now occupying much of the office space left vacant as a result of Nuclear Staff reductions.
The Nuclear Staff Office Building will be left in place and continue to be used by other NIPSCO departments to meet NIPSCO's increasing nc 3 for office space.
The Bailly N-1 Construction Warehouse The Construction Warehouse is a 60 ' x 180 ' steel building located approximately 100' west of Bailly Unit #10 combustion turbine building.
This building was constructed in 1975 to provide storage and prefabrication areas for Bailly N-1.
Currently, approximately one-half of this building is being used for storage of nuclear equipment while the other half is being used to supplement the storage area requirements of NIPSCO's existing fossil Units #7 and #8.
Following the removal of the nuclear equipment, this building will be used at the Bailly site as a warehouse and/or machine shop for the existing units.
The Bailly N-1 Civil Test Lab The Civil Test Lab is a 24' x 76' steel building located east of NIPSCO's ash ponds and wastewater treatment plant.
This building was constructed in 1978 to provide facilities for testing concrete and reinforcing bar to be used in the construc-tion of Bailly N-1.
These facilities are now planned to be used as a quality assurance laboratory.
The Sewage Treatment Plant The facilities for Bailly N-l's sewage treatment plant are housed in a steel building approximately 140' x 25' located near the southeast corner of the Bailly N-1 excavation.
The plant _
handles raw sewage from the existing generating station as well
as the Bailly N-1 office and warehouse.
The need for the Sewage Treatment Plant is not affected by cancellation of Bailly N-1.
34,500 VOLT CONSTRUCTION LINE The 34,500 volt, three phase line (the line) placed on wooden poles and traversing from the Dune Acres Substation (at the extreme southeastern pcrtion of'the Bailly site) along the Bailly site entrance road, was installed in 1974.
The line is used to supply the electrical power to the following:
The civil test laboratory building.
The newly constructed wastewater treatment plant substation for Units 37 and #8.
The Units #7 and #8 pollution control system construc-tion substatian.
The Bailly N-1 construction substation which is used to supply power to the Nuclear Staff office building, construction warehouse, sewage treatment plant, parking lot lights for fossil unit construction employees and parking lot lights for the fossil unit operating employees.
The line and all associated substations must remain in service as the power provided for all of the above-listed functions must continue for operation sif the existing fossil plants, th'eir pollution control equipment and the wastewater and sewage handling systems.
SLAGGED LAYDOWN AREA AND RAILROAD SPUR The slagged laydown area which was installed north of the Dune Acres Substation, along with a railroad spur, will be left in place and utilized by fossil plcnt and substation departments.
BAILLY N-1 EQUIPMENT NIPSCO began receiving and storing Bailly N-1 equipment in 1972.
At present, equipment is stored in two' ( 2 ) warehouses on the Bailly site, two (2) warehouses at the Michigan City Generating Station, one (1) warehouse in the Town of Chesterton and one (1) warehouse at the Port of Indiana.
NIPSCO intends to i
seek interested buyers for this equipment and dispose of it as soon as practicable.
g e
w,n
-e,
,,vg
,e--
,