05000339/LER-1980-011-03, /03L-0:on 800520,personnel Air Lock Doors Would Not Seal Completely,Causing Air Leakage While Performing Surveillance Test 2-PT-62.4.Caused by Leakage Past Seals on Inner & Outer Doors.New Seals Were Installed

From kanterella
(Redirected from ML19318A619)
Jump to navigation Jump to search
/03L-0:on 800520,personnel Air Lock Doors Would Not Seal Completely,Causing Air Leakage While Performing Surveillance Test 2-PT-62.4.Caused by Leakage Past Seals on Inner & Outer Doors.New Seals Were Installed
ML19318A619
Person / Time
Site: North Anna 
Issue date: 06/19/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19318A618 List:
References
LER-80-011-03L-02, LER-80-11-3L-2, NUDOCS 8006230500
Download: ML19318A619 (2)


LER-1980-011, /03L-0:on 800520,personnel Air Lock Doors Would Not Seal Completely,Causing Air Leakage While Performing Surveillance Test 2-PT-62.4.Caused by Leakage Past Seals on Inner & Outer Doors.New Seals Were Installed
Event date:
Report date:
3391980011R03 - NRC Website

text

LEAR REGULATORY COMMISSION LICENSEE EVENT REPORT CONTROL BLOCK / / / / / / / (1)

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

/0/1/

/V/A/N/A/S/2/ (2)

/0/0/-/0/0/0/0/0/-/0/0/ (3)

/4/1/1/1/1 (4)

/ / / (5)

LICENSEE CODE LICENSE NUMBER LICENSE TYPE CAT

/0/1/

/L/ (6)

/0/5/0/0/0/3/3/9/

(7)

/0/5/2/0/8/0/

(8)

/0 /6 /1/9 /8 /0 (9)

DOCKET NUMBER EVENT DATE REPORT DATE EVENT. DESCRIPTION AND PROBABLE CONSEQUENCES (10)

/0/2/

/

On May 20, 1980, with the unit in Mode 3, it was discovered that the personnel /

/0/3/

/

air lock doors would not seal completely thus causing air leakage while per _ /

//0/4/

/

forming surveillance test 2-PT-62.4.

Since the plant had never been critical /

/0/5/

/

the health and safety of the general public were not affected. This is con-

/

/0/6/

/

trary to T.S. 3.6.1.3 and reportable pursuant to T.S. 6.9.1.9.b.

/

/0/7/

/

/

/0/8/

/

/

SYSTEM

CAUSE

CAUSE COMP.

VALVE CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE

./0/9/

/S/A/ (11) /E/ (12) /B/ (13) /P/E/N/E/T/R/ (14) g/ (15)

/_Z/ (16)

SEQUENTIAL OCCURRENCE REPORT REVISION LER/R0 EVENT YEAR REPORT NO.

CODE TYPE NO.

(17) REPORT NUMBER

/8/0/

/-/ /0/1/1/

/\\/

/0/3/

/L/

/-/

M/

ACTION FUTURE EFFECT SHUTDOWN ATTACHMENT NPRD-4 PRIME COMP.

CCMPONENT TAKEN ACTION ON PLANT METHOD HOURS SUBMITTED FORM SUB. SUPPLIER MANUFACTURER

/B/ (18)

/Z/ (19) /Z/ (20)

/Z/ (21) /0/0/0/0/ (22) /Y_/ (23)

/2/ (24) /A/ (25) /C/3/1/0/ (26):

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS (27)

'/1/0/

/

The personnel air lock did not seal due to leakage past the seals on the inner /

./1/1/

/

and outer doors. New seals were installed on the outer door and the inner door /

/1/2/

/

seals required cleaning. Subsequent to maintenance, 2-PT-62.4 was performed

/

/1/3/

/

with satisfactory results.

/

/1/4/

f,

/

FACILITY METHOD OF STATUS

% POWER OTHER STATUS

/ ( 0) DISCOVERY DISCOVERY DESCRIPTION (32)

/1/5/

/B/ (28)

/0/0/0/ (29) /

NA

/B/ (31)

/During performance of PT/

ACTIVITY CONTENT RELEASED OF RELEASE AMOUNT OF ACTIVITY (35)

LOCATION OF RELEASE (36)

/1/6/

/Z/ (33)

/Z/ (34) /

NA

/

/

NA

/

PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION (39)

'/1/7/ /0/0/0/ (37) /Z/ (38) /

NA

/

PERSONNEL INJURIES NUMBER DESCRIPTION (41)

/1/8/ /0/0/0/ (40) /

NA

/

LOSS OF OR DAMAGE TO FACILITY (43)

TYPE

DESCRIPTION

'/1/9/

/Z/ (42) /

NA

/

PUBLICITY ISSUED DESCRIPTION (45)

NRC USE ONLY l/2/0/

/N/ (44) /

NA

/////////////

' 800623 @

NAME OF PREPARER W. R. CARTWRIGHT PHONE (703) 894-5151

m

~

1 Virginia Electric and Power Company North Anna Power Station, Unit #2

Attachment:

Page 1 of 1 Docket No. 50-339 i

Report No. LER 80-011/03L-0

Description of Event

On May 20, 1980, with the unit in Mode 3, the personnel air lock seal leakage test, 2-FT-62.4, was performed and leakage was detected.

This is contrary to T.S. 3.6.1.3 and reportable pursuant to T.S.

6.9.1.9.b.

Probable Consequences of Occurrence Since the plant had never been critical prior to this occurrence, there was no fission product buildup in the core and the health and safety of the general public were not affected.

Cause of Event

Examination of the personnel air lock showed that the inner door

- seal gasket required cleaning and the outer door seal needed to be replaced.

Immediate Corrective Action

The inner door seal was cleaned and the outer door seal was replaced.

Scheduled Corrective Action The periodic test 2-PT-62.4 shall be performed after each opening, except when the air lock is being used for multiple entries, then at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

Actions Taken to Prevent Recurrence No further actions are required.

b