RO 50-313/77-11:on 770331,4.71 Ci Pu-Be Source Used by Plant Personnel Found Not Tested for Leakage within Six Months. Caused by Personnel Error.Importance of Conducting Test on Schedule re-emphazed.Source Tested & Found Acceptable
ML19317H071
Person / Time
Site: Arkansas Nuclear 
Issue date: 04/29/1977
From: Mardis D
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19317H071 (4)
RO 50-313/77-10:on 770331,leak Rate Test Improperly Performed on Reactor Bldg Escape Hatch.Caused by Personnel Error Failing to Check Cavity Between Hatch Doors.Hatch Retested & Found Acceptable
ML19317H068
Person / Time
Site: Arkansas Nuclear 
Issue date: 04/29/1977
From: Mardis D
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19317H068 (4)
Forwards ROs 50-313/77-10 & 50-313/77-11
ML19317H066
Person / Time
Site: Arkansas Nuclear 
Issue date: 04/29/1977
From: Rueter D
ARKANSAS POWER & LIGHT CO.
To: HOWARD E M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19317H066 (1)