Notice of Violation from Insp on 720509-12,24-26 & 0612
ML19317G193
Person / Time
Site: Crystal River 
Issue date: 07/24/1972
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19317G178 List:
References
50-302-72-02, 50-302-72-2, NUDOCS 8002280835
Download: ML19317G193 (1)


Text

_

m n o, s

ENCLOSURE

,DGCKET NO. 50-302

~

' Certain activities under your license appear to be in noncompliance-vith l

AEC regulations and with your procedures as identified below:

1.

Criterion XIII of Appendix B to 10 CFR 50, " Handling, Storage, and Shipping," states, in part, " Measures shall be established to con-trol the handling, storage, shipping, cleaning and preservation of material and equipment in accordance with work and inspection instruc-tions to prevent damage or deterioration..

Your procedure FS-III-11b, " Receipt, Inspection, Handling, Storage, and Installation of Ss,fety and Pressure Relief Valves," states, in part, " Valves must be inspected to verify acceptance of valve upon delivery.

. Verify mark number or serial number.

Valves must be periodically inspected to verify they are stored satis-factorily.

. This inspection period is thirty (30) days."

Contrary to the above requirements, apparent deficiencies were iden-tified in the storage and inspection program.

In particular:

a.

The receiving inspection report dated July 12, 1971, documented C/

the receipt of the electromatic relief valve, RC-RV2, and one safety relief valve, RC-RV13. The valves actually received vere the electromatic relief valve, RC-RV2, and the isolation gate valve, RC-V2.

b.

In-sto.1ge inspections were not completed between the periods July 12, 1971, to February 8, 1972, and March 31, 1972, to May 11, 1972.

The two valves were " misplaced" from July 12, 1971, to c.

February 7, 1972.

2.

Criterion V of Appendix B to 10 CFR 50, " Instructions, Procedures, and Drawings," states, in part, " Activities affecting quality shtl1 be prescribed by documented instructions,... and shall be accor-plished in accordance with these instructions, procedures.

Criterion IX of Appendix B to 10 CFR 50, " Control of Special Processes,"

states, in part, " Measures shall be established to assure that special processes including velding,.

are controlled and accomplished by

. qualified personnel using qualified procedures,.

Contrary to the above, the control of velding rod was not being implemented in that quantities of type 7318 velding rod, a type re-quiring a special environment control prior to use, were found lying es

[

')

around to the extent that veld quality could be compromised.