Oconta Unit 2 UNIT DATE 2/10/77
)
DOCKET NO.
50-270 PREPARED BY L. J. Bare OPERATING STATUS 1.
REPORTING PERIOD: January 1 THROUGH January 31, 1976 GROSS HOURS IN REPORTING PERIOD:
744.0 2.
CURRENTLY AUTHORIZED POWER LEVEL (MWt): 2568 NET CAPABILITY (MRe-Net):
860 3.
POWER LEVEL TO WHICH RESTRICTED (IF ANY):(MWe-Net) 4.
REASONS FOR RESTRICTION (IF ANY)
This Month Year to Date Cumulative 5.
NUMBER OF HOURS THE REACTOR WAS CRITICAL 744.0 744.0 14971.0 6.
REACTOR RESERVE SHUTDOWN HOURS 7.
HOURS GENERATOR ON-LINE 744.0 744.0 14509.54 8.
UNIT RESERVE SHUTDOWN HOURS 9.
GROSS THERMAL ENERGY GENERATED (MWH)1916321 1916321 34682052 10.
GROSS ELECTRICAL ENERGY GENERATED (MWH) 652990 652990 11808596 11.
NET ELECTRICAL ENERGY GENERATED (MWH) 626360 626360 11210483 12.
REACTOR SERVICE FACTOR 100.0 100.0 71.2 3
13.
REACTOR AVAILABILITY FACTOR 100.0 100.0 69.5 14.
UNIT SERVICE FACTOR 100.0 100.0 69.0 15.
UNIT AVAILABILITY FACTOR 100.0 100.0 69.0 16.
UNIT CAPACITY FACTOR (Using Net 97.9 97.9 62.0 Capability) 17.
UNIT CAPACITY FACTOR (Using Design Mwe) 94.9 94.9 60.1 ~
18.
UNIT FORCED OUTAGE RATE 0
0 24.4 19.
SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE & DURATION OF EACH:)
Refueling - July 17, 1977 - 6 weeks 20.
IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
REACTOR SERVICE FACTOR = HOURS REACTOR WAS CRTTICAI' X 100
!!OURS IN REPORTING PERLOD REACTOR AVAILABILI'lT FACTOR = HOI?RS REACTOR L'AS AVAILiSLR TO CPERATE X 100 llCURS IN REPORTING PERICD UNIT SERVICE TACTCR
= HOIT A GENERATO? ON LINE 0
IiOURS diYdORYd;G PCliig UNIT AVAII.\\BILITY FACTOR = UGURS LINTT WAS AVAIT ABLE TO GENEPATE X 100 HOURS IN REPuk!1NG L'ERIOD UNIT CAPACITY FACTCR
= NET ELECTRICAL P0hER GENERATFD
_,, gg (N t Capability or Design mwe-L L).1 X 1100iG IN R & a.'lSO UNIT FORCED OUTACE :tA17.
- P OUTAGE HOURS Q 1 f 'I X 100 HOL*RS GENERATOR ON NE IFORCED OU CAGE HOURS
DOCKET NO. 50-270 UNIT Oconee Unit 2 2/10/77 DATE AVERAGE DAILY UNIT POWER LEVEL MONTH January, 1977 AVERAGE DAILY POWER LEVEL AVERAGE DAILY POWER LEVEL DAY (MWe-net)
DAY (MWe-net) 845 1
839 37 838 43 2
18 841 847 3
39 844 840 4
845 849 5
21 6
22 7
843 849 23 845 843 8
845 844 g
25
'1 10 26 848 836 11 27 833 836 12 28 842 838 13 29 14 30 15 843 842 31 844 16 DAILY UNIT POWER LEVEL FOR.\\1 INSTRUCTIONS On this form, list the average daily unit power revel in.1We-net for each day in the reporting month.
\\
r Compute to the nearest whole megawatt.
l These figures will be used to plot a graph for each reporting month. Note that by using maximum l
dependable capacity t'or the net electrical rating of the unit. there mas be.a casions when the daily l
average power level exceeds the 1001 line f or the restricted power lesel hne). in such cases, the average daily unit power output sheet should be footnoted to nplain the :pparent anomaly.
D CKET NO. 50-270 UNIT SHUTDOWNS UNIT NAMti Oconee Unit 2 2/10/77 DATli REPORT MONTil January, 1977 TYPE METHOD OF F-FORCED DURATION SHUTTING DOWN NO.
DATE S SCHEDULED (HOURS)
REASON (1)
THE REACTOR (2)
CORRECTIVE ACTIONS / COMMENTS rr (1) REASON O) MET 1tOD A EQUIPMENTI ALLURE (EXPLAIN) l-MANUAL B-MAINT. OR TEST.
2-MANUAL C-REFUELING
~
SCR AM D-REGULATORY RESTRl(TION 3-AUTOM ATIC E-OPERATOR TRAINING AND SCR AM LICENSE EXAMINATION 4-Other F-ADMINISTRATIVE G-OPERATIONAL ERROR (EXPLAIN)
Il-OlllLR (LXPLAIN) l
SUMMARY
l No outages this month.