j D:;nz Powra CoxPm Powza Sc :. :xe, 422 sor: r Caraca sint :. Curnt.or r,N. C. 2eaos October 14, 1971 A. c..mn e o.rox we u

4.. a

.u u..

..c. o.c......... c.

3!r. John G. Davis, Director U.S. Atomic Energy Commission Divn of Compliance Region I! - Suite 818 230 Peachtree Street,. Northwest Atlanta, Georgia 30303

Dear LIr. Davis:

In answer to your letter of Sep; ember 10, 1971, specifically enc'.osu"e Dcchet Nos. 50-270, 287, relating to certain items that appeared to be in noncompliance with 10 CFR Part 50, Appendix 3

" Quality Assurance Criteria for Nuclear Pcwer Plants" - your statemen: ' hat we proceeded with the installation of the feedwater headers on steam =menerator 23 in Uni: 2 at Oconee without a written approved J

procedure is correct. However, Criterion V states that activities affecting quality shall be prescribed by docume nied instructions, procedures, or drawings.

We did have approved E&W drav.ings which were used as installation instructicns before we began installation cf the feedwat.er headers. These drawings are B&W 129323E Revision 9, B&W 129302E Revision 12, and B&W 129322E Revision 9.

B&W site representatives were also no:ified before we began installing me header, since the warehousing of B&T equipmen: for the nuclear steam supply system is centrolled by B&W.

The feedwater header did have some gouges en the support lugs, bu::here were no are strikes anywhere en the steam genera:or upon inspection by our NDT personnel in an effort to tighten up cn our centrol of te activities affec:ing qualny, we h::.ve re-instruc:ed our craf: people as to de imper:ance of all areas reic. ting to de nuc'. ear s: carn supply system and 21: in all cases, a Duke c.ualitv, co n:rci represen:a:ive and a B&W site represen:anve must be no:ified before instalia:icn of B&W equipment. In this specific case, a procedure for Se repair of de feedwater neader support plates and the re-installa:ica of me feedwater header was wrinen b.v Duke and an. oroved b.y B&W, and the remaininz work was accomplished under o

2is precedure. It is our inten:icn :o supplemen: approved ins::11ation drawines a

with wrinen procedures en future instalia icn of equipment.

If you have any further questions, please advise.

Since rely, d.

H.V

. N.M'D C D. 7 :U. 5.

= ^

ACT!hr A. C. Thie s m v.

cc:

Alr. C. E. Watkins

.A. ;. ",

.?

A!r. E. D. Powell & 11. W. H. Cwen

,. <., a :.