ML19316A259

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Repts 50-269/77-03,50-270/77-03 & 50-287/77-03 on 770308-11.Noncompliance Noted
ML19316A259
Person / Time
Site: Oconee  
Issue date: 04/07/1977
From: Long F
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Parker W
DUKE POWER CO.
Shared Package
ML19316A249 List:
References
NUDOCS 7912050833
Download: ML19316A259 (2)


See also: IR 05000269/1977003

Text

  1. E8h

UNITED STATES

-

,[

g[o

NUCLEAR REGULATORY COMMISSION

g

O

o

R EGloN 11

'

{

,*c(

$

230 PE ACHTREE ST R EET. N.W. EUITE 1217

I

ATLANTA. GEORGI A 30303

f

'

'

o

f

\\

'%J

'

  • ...*

gpg

7 D7

In Fe' ply Refer To:

IE:CEA

50-269/77-3

50-270/77-3

50-287/77-3

Duke Power Company

Attn:

Mr. William O. Parker, Jr.

Vice President, Steam Production

P. O. Box 2178

422 South Church Street

Charlotte, North Carolina

28242

Gentlemen:

This refers to the inspection conducted by Mr. C. E. Alderson of this

office on March 8-11, 1977, of activities authorized by NRC Operating

License Nos. DPR-38, DPR-47 and DPR-55 for the Oconee Units 1, 2 and 3

facilities, and to the discussion of our findings held with Mr. J. E. Smith

at the conclusion of the inspection.

Areas examined during the inspection and our findings are discussed in the

,

enclosed inspection report. Within these areas, the inspection consisted of

selective examination of procedures and representative records, interviews

with personnel, and observations by the inspector.

i

We have also examined actions you have taken with regard to previously

I

identified enforcement matters and unresolved items.

The status of these

items ,is identified in Sections II and IV of the smmary of the enclosed

report.

During the inspection, it was found that certain activities under your

license appear to be in noncompliance with NRC requirements. These items

and references to pertinent requirement 1 are listed in Section I of the

summary of the enclosed report.

i

This notice is sent to you pursuant to the provisions of Section 2.201

of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal

Regulations.

Section 2.201 requires you to submit to this office,

i

within 20 days of your receipt of this notice, a written statement

or explanation in reply including:

(1) corrective steps which have

been taken by you, and the results achieved; (2) corrective steps

which will be taken to avoid further noncompliance; and (3) the date

when full compliance will be achieved.

fD

7912050

.

._ _

_

_

-

- _ .

_ _ _

_

.

!

(~N

Duke Power Company

-2-

'

l

,

'

.

In accordance with Section 2.790 of the NRC's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter

and the enclosed inspection report will be placed in the NRC's Public

Document Room.

If this report contains any information that you believe

to be proprietary, it is necessary that you submit a written application

to this office requesting that such information be withheld from public

disclosure.

If no proprietary information is identified, a written

statement to that effect should be submitted.

If an application is

su'umitted, it must fully identify the bases for which information is

claimed to be proprietary.

The application should be prepared so that

information sought to be withheld is incorporated in a separate paper

and referenced in the application since the application will be placed

in'the Public Document Room. Your application, or written statement,

should be submitted to us within 20 days.

If we are not contacted as

specified, the enclosed report and t.his letter may then be placed in

the Public Document Room.

Should you have any questions concerning this letter, we will be glad to

discuss them with you.

Very truly yours,

1

-

__

F. J. Long, Chief

Reactor Operations and Nuclear

Support Branch

Enclosure:

IE Inspection Report Nos.

50-269/77-3, 50-270/77-3

50-287/77-3

,

.

s

-

+e

-