- _ _ - _.

LIkITINGCONDITIONSFOROpERATION 4.0 SURVEILLANCE REQUIREMENTS 3.0 A.

Reactor Vessel Internals Vent Valves A'. ' Reactor Vessel Internals Vent Valves l.

The structural integrity and 1.

At least once each refueling operability of the reactor cycle, each reactor vessel internals vent valves shall internals vent valve shall be maintained at a level be demonstrated operable by:

consistent with the acceptance criteria in a.

Conducting a remote visual specification (

).

inspection of visually accessible surfaces of the value bcdy and disc seal'ing faces and evaluating any observed surface irregularities, b.

Verifying that the value is not stuck in an open position, and Verifying through c.

manual actuation that the value begins to open frem the fully closed position with a force equivalent to < (0,15) p,sid,-

and is fully open with a force equivalent to

< (0.30) psid.

7911210 [37

BASES 3/4.0 Reactor Vessel Internals Vent Valves 1.

The internals vent valves are provided to relieve the pressure generated by steaming in the core following a LOCA so that the core remains sufficiently covered.

Inspection and manual actuation of the internals vent valves (1) ensure Operability, (2) ensure that the valves are not open during normal operation and (3) demonstrate that the valves begin to open and are fully open at the forces equivalent to the differential pressures assumed in the safety analysis.

4 0

.