s OCT 121976 OISTRIBUTION Docket Files NRC PDRs LOCAL PDR Dockets.Nos. /270/237 ORBil Reading TJCarter ASchwencer Duke Power Company DNeighbors ATTt: Mr. William O. Parker, Jr.

GZech Vice President SMSheppard Steam Production VStello Post Office Box 2173 DEisenhut 422 South Church Street OELD Charlotte, North Carolina 28242 OI&E(3)

ACRS (16)

Gentlemen:

TBAbernathy JRBuchanan RE: OCO. NEE STATICN, UNITS 1, 2 & 3 Dur review of your Technical Specifications indicates that no requirements exist for the testing of reactor core internal vent valves. Since the vent valves are assumed functional to prevent vapor lock in the reactor vessel after a postulated cold leg break, it is considered appropriate that Technical Specifications be proviced to verify that the vent valves are free to operate and that the forces required to operate them do not exceed those forces that would be generated by the differential pressures expected to exist across the reactor inlet and outlet plenu::s, as identified in your FSAR, should a vapor lock condition develop followig a LOCA.

You are requested to propose changes to your Technical Specifications at least 90 days prior to your next refueling outage that will implement surveillan:e '.esting requirements to accomplish the above. Sample technical specifications are enclosed for guidance in prepari.m; your submi ttal.

Sincersly, Original signed by A. Schwencer, Chief Operating Reactors Branch fl Division of Operating Reactors

Enclosure:

Sample Technical Specifications cc w/ encl: See next page N

O "'C ' * @

}.-

g e ROBf1 ------ M -

>/

" *" *Dre bors:1b GZech /

ASci cer

-10/h/76-10/ 4 7 le/FMG -

Feces AIC 318 t Rev. 9 5 5) AECM 0240

  1. u. e movsnmassm? rninttna orricu sera.aae ies 7 911210 (3 J p

/

Duke Power Company October 12, 1976 cc: Mr. William L.. Porter Duke Power Company P. O. Box 2173 422 South Church Street Charlotte, North Carolina 28242 tir. Troy 3. Conner Conner & Knotts 1747 Pennsylvania Avenue,!1. W.

Washington, D. C.

20006 Oconee Public Library 201 South Spring Street Walhalla, South Carolina 29691 t