ML19312D776
| ML19312D776 | |
| Person / Time | |
|---|---|
| Site: | 07001113 |
| Issue date: | 11/20/1979 |
| From: | Sutherland J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Alkema R GENERAL ELECTRIC CO. |
| Shared Package | |
| ML19312D755 | List: |
| References | |
| NUDOCS 8003250321 | |
| Download: ML19312D776 (2) | |
Text
-
i f* ** %,
8[
[o UNITED STATES 4
g NUCLEAR REGULATORY COMMISSION o
6
,e REGION il g-~) g o
101 MARIETTA ST., N.W SUITE 3100 V k.
,o[
ATLANTA, GEORGIA 30303 NOV 2 01979 In Reply Refer To:
RII:DJP 70-1113/79-20 General Electric Company Attn:
R. J. Alkema, General Manager Wilmington Manufacturing Department Post Office Eax 780 Wilmington, North Carolina 28401 Gentlemen:
c This refers to the inspection conducted by D. J. Perrotti of this office on October 25-26, 1979 of activities authorized by NRC License No. SNM-1097 at the Nuclear Fuel Division facility, and to the discussion of our findings held with E. A. Lees at the conclusion of the inspection.
Areas examined during the inspection and our findings are discussed in the enclosed inspection report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspectors.
We have examined actions you have taken with regard to previously reported unresolved items. The status of these items is discussed in the enclosed report.
During the inspection, it was found that certain actisities under your license appear to be in noncompliance with NRC requirements. This item and references to pertinent requirements are listed in the Notice r,f Violation enclosed here-with as Appendix A.
This notice is sent to you pu:suant to the provisions of Section 2.201 of the NRC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations. Section 2.201 requires you to submit to this office, within 20 days of your receipt of this notice, a written statement or explanation in reply including:
(1) corrective steps which have been taken by you, and the results achieved; (2) corrective steps which will be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.
If this report contains any information that you (or your contractor) believe to be proprietary, it is necessary that you make a written application within 20 days 8003250 32*l
NOV 2 01979 e
General Electric Company.
to this office to withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and.hould be prepared so that proprietary information identified in the application is contained in a separate part of the document.
If we do not hear froa you in this regard within the specified period, the report will be placed in the Public Document Room.
Should you have any questions concerning this letter, we will be glad to discuss them with you.
Sincerely, 4-(
4' r
J. T. Sutherland, Chief Fuel Facility and Materials Safety Branch Snclosures:
1.
Appendix A, Notice of Viol tion 2.
Inspection Report No. 70-1113/79-20 cc w/ enclosures:
A. L. Kaplan, Manager Licensing and Compliance Audits Post Office Box 780, Mail Code J-26 Wilmington, North Carolina 28401 L. M. Vaughan, Manager Nuclear Materials Management Post Office Box 780, Mail Code K-88 Wilmington, North Carolina 28401 i
l i
i
,-