ML19312C699

From kanterella
Jump to navigation Jump to search
Forwards Draft Summary of Radioactive Effluent Releases from Facilities.Info to Be Included in NRC Rept of Effluent Releases from Operating Reactors.Requests Verification of Data
ML19312C699
Person / Time
Site: Oconee  
Issue date: 08/26/1977
From: Schwencer A
Office of Nuclear Reactor Regulation
To:
DUKE POWER CO.
References
NUDOCS 7912190901
Download: ML19312C699 (7)


Text

_.

r.

~

AUG 2 61977 ocket N

FUK LOCAL PDR ORB #1 Reading

< J0 259 -.

ASchwencer Docket No.

50-270 SMSehppard and 50-287 DNeighbors OELD OI&E(3)

DEisenhut Licensee KParrish RE: OCONEE TJCLEAR STAT 10fi, 'JNITS 1, 2 & 3 TBAbernathy JRBuchanan Gentl emen:

ACRS(16)

The NRC is presently preparing a summary of radioactive effluents released from commercial nuclear power plants during 1976.

The report will be similar to NUREG-02i8, ~1adioactive Materials Released from Nuclear Power Plants (1975)".

In order to verify the accuracy of the infonnation before its publication, a draft copy of the data with respect to your plant (s) is enclosed for your review. We would appreciate receiving your comments and suggested changes by September 16, 1977.

If there are changes to the enclosure that result from other than our transcription error, we request that you file an amendment to your semi-annual reports which includes a reason for the change. Also, please provide answers to any questions attached to or on the enclosed data sheets, the name and telephone number of the individual we should contact in the event that we find it necessary to clarify your comments in answer to this request.

Please provide a written response even if no changes to the data are required.

Responses should be addressed to:

U. S. Nuclear Regulatory Commission Of fice of Management Infonnation & Program Control Operating Data Branch,12105 MNBB Washington, D. C.

20555 Any questions should be referred to T. R. Decker (301-492-7735). A copy of the final report will be sent to you.

Sincerely, Albert Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors bL ~

l,.

/

Enclosure:

d l

Draft Cony of Data

[

'/

DOR:0R4fT 00R:0RB#3 10R:0RB#1/C i

DNeiNors:1 b KParrishN ASchwefider yo39 onQn/

n

(

"~~

~"

8/26/77 8/Lh77

\\

8/f.p77 un, v.c new u., m war w nua e u....av e....

..,,. a, e,...,...u..

~

uniTas sTArms

,,/

a-

  • *4 NUCLEAR REOULATORY COMMISSION 3iW[jl]z wasmwaTow.o.c.2ases

%k

%,M AUG 2 61977 Docket No. 50-269 50-270 and 50-287 Licensee RE: OCONEE NUCLEAR STATION, UNITS 1, 2 & 3 Gentlemen:

The NRC is presently preparing a summary of radioactive effluents released from come.ercial nuclear power plants during 1976.

The report will be similar to NUREG-0218, " Radioactive Materials Released from Nuclear Power Plants (1975)".

In order to verify the accuracy of the infonnation before its publication, a draft copy of the data with respect to your plant (s) is enclosed for your review. We would appreciate receiving your comments and suggested t.hanges by September 16, 1977.

If there are changes to the enclosure that result from other than our transcription error, we request that you file an amendment to your semi-annual reports which includes a reason for the change. Also, please provide answers to any questions attached to or on the enclosed data sheets, the name and telephone number of the individual we should contact in the event that we find it necessary to clarify your comments in answ" to this request.

Please provide a written response even if no changes to the data are required.

Responses should be addressed to:

U. S. Nuclear Regulatory Commission Office of Management Infonnation & Program Control Operating Data Branch,12105 MNBB Washington, D. C.

20555 Any questions should be referred to T. R. Decker (301-492-7735). A copy of the final report will be sent to you.

Sincerely, 7

/

.'lgYdhb l

/

Albert Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors

Enclosure:

Draft Copy of Data cc w/ enclosure:

See next page

o

,)

Duke Power Company 2-August 26, 1977 cc: Mr. William L. Porter Duke Power Conpany P. O. Box 2178 422 South Church Street Charlotte, North Carolina 28242 J. Michael McGarry, III, Esquire DeBevoise & Liberman 700 Shoreham Building 806-15th Street, NW.,

Washington, D.C.

20005 Oconee Public Library 201 South Spring Street Walhalla, South Carolina 29691 e

- - ~, -.,.

~

j-F4CILifYs DCONEC 1.2C 3 00CRET Nos 50-269/2T0/287 1

TYPE:

PWR LICENSED POWER IMWil 2564.0 2568.0 2568.0 LOCATION:

0 MI W GREENVILLE SC INITIAL CRITICALITY 8 04/19/73 11/11/73 09/05/74 COOLING WATER SOURCE:

RE0 WEE LARE OPEAAil0M i

G4055 THERMAL GEteERATION 12161569.0 13093303.0 14450167.0 MWHT 9El [LECTRICAL 39938R4.0 4228972.0 4755200.0 MWHE It*FRMAL CAPACITY FACTOR

$3.9 58.0 64 1 PER C N IDURING COMMLHCIAL OPERATIONI

SUMMARY

OF EFFLUENTS

  • If Sunnny A I R 80R*3E pft/vEd /?EE Al TOI AL NOBLE GA5ES 4.39E*04 CURIES DIFFC#EdF T2/8M

~

al TOTAL I-131 1.25E-01 CURIES

/Jo rope,5 P/Ensc Cl total HALOGEN 5tINCLUDING l-tall 1.57E-01 CURIES Egph,is/ D,kre,oAWCf.

Di TOTAL PARTICULATES 1.47E-03 CURIES El TOTAL TRITIUM 5.02E*02 CUPIES LICUID

)

s Al TOTAL MIXE0 FISSION AND ACTIVATION PRODUCTS 7.23E*00 CURIES 88 TOTAL TRITIUN 2.19E*03 CURIES 1

Cl OISOLVED NOBLE GASES 1.11E*00 CURIES

[

DT VOLUME OF L100I0 WASTE RELEASED 1.95E*07 LITERS YOLUMk0FOILUTIONWATER El.

1.21E*11 LITER 5 SOL ID W AS T E Al VOLUME 2.22E*03 CUSIC METERS In el ACilVITY 7.83E*02 CURIES 4

1 Cl NuduER OF 5HIPMENTS 1.68E*02

e o

AIR 90RNE EFFLUENTS (CURIESI p

N0 ELE GA5 AR-41 2.55E+02 KR-85 3.47E+01 KR-8SM 8.23E+01 KR-87 2.69E+01 KR-88 1.llE+02 XE-tilH 2.04E+00 s,

XE-133 4.2tE+04

\\_)

XE-133M 3.46E+02 XE-135 9.75E+02 XE-13SM t.6sE+00 XE-137 5.05E-04 XE-138 4.49E+00 HALOGENS l-131 1.25E-01 1-132 8.10E-05 I-133 3.14E-02 I-134 2.74E-05 I-135 1.25E-05 PARTICULATES CR-51 1.24E-06

.MN-54 5.47E-06 00-58 3.15E-04 CD-60 1.10E-05 R8-88 2.93E-01

's, SR-89 9.78E-04 SR-90 8.5tE-06 MD-99 4.15E-08 TC-99M 1.74E-08 t

CS-134 9.31E-06 C5-136 3.96E-07 C5-137 1.06E-05 C5-138 1.63E-02 BA-139 2.93E-06 CE-144 1.00E-0F AG-11'OM 9.ItE-06 SAILA-140 1.17E-04 NP-239 2.01E-05 MN-56 1.53E-05 b

ZR-97 1.62C-06 AG-108M 1 63E-OF SN-123M 4.23E-05 TRittuM H-1 S.0?F+02

e f

LIQUID EFFLUENTS (CURIESI AR-41 2.06E-05 ER-85M 3.78E-04 KR-88 2.96E-03 XE-131M 3.97E-04 XE-133 1.0FE+00 XE-113M 1.59E-03 XE-135 3.96E-02 1-131 I.9tE*00 1-132 1.24E-04 1-133 8.07E-02

.x t-134 1 66E-04 Q

1-135 5.45E-04 NA-24 7.28E-03 CR-51 7.640-02 Nta-54 2.3tE-01 NN-56 2.99E-04 C0-57 1.18E-03 Co-58 2.0tE+00 FE-59 6.12C-03 CU-60 3.68E-01 N!-65 1.84E-05 RB-88 2.95E-02 SR-89 1.04E-02 Sn-90 6.50E-04 SR-92 3.2RE-04 2d-95 t.74E-OS No.-95 2.24F-03 2R-97 1.22E-04 ND-97 2.10E-02 HO-99 5.93E-03 TC-99M 5.24E-02 I

RU-103

'4. 7 9 E - 0 5 AG-108M 2.48E-05 AG-!!ON 3.30F-02 I

C0-115 4.tSE-03 CD-t!5M 5.01E-04 SH-125 6.16E-01 CS-134 6.05E-01 C5-116 4.67E-02

[*

CS-137 ~

1.04E*00 l

4 h4-139 3.42E-04 BA/LA-140 1.82E-02 CE-144 1.29E-04

]

b HF-181 2.48E-05 W-187 1.00E-04 i

NP-239 1.95E-05 Y-92 1.18E-05 IN-t!5M 4.97E-04 i

SN-125M 1.5tE-02 CE-134 3.!TE-03 TRITIUM

P S

/

e J

o e

t 9

4 6

e e

N e

s,.--

Y9 W

e gs

- M S

N i

I e

9Z e,

4 h

a 6

m G

O g