Text

_ _ _ _ _ _ _

-

-

Roi k

.

.

O

.

W

MAR 2 B

G. S. Spaneae, Chief, Construction and Operation Branch, Region V

,

ASSIST INSPECTION

wnmWTO IGNICIPAL UTILITT DISTRICT, BANCHO

SECO - LOCKET 30. 50-312

Attached la a copy of Imon's portion of the inspection report which

covers the inservice inspection test on tendon 1150. It appears from

what was observed during the test that progressive damage is inflicted

on the tendon by the testing and that the procedures used were not

adequate or well thought out.

We have discussed the breaking of the wires with DL and they will

ovalusta the generic implication of this mode of failure and its

l

.

effect on the Imag term inservice survef11amea program.

In your cors;;g-Mes with the utility we recommend that you list

the commitmeate made by the applicant.

l

If we can be of further service, please do noc hesitate to call on

-

us.

/S/

Karl V. Seyfrit, Chief

1

Technical Assistance Branch

Directorate of Bagulatory Operations

i

cca

J. G. Davis, 20

3. E. Grier, 20

A. Johnson, 20 V

L. Shao, L

A. Schwencer, L

l

3. C. Buckley, L

i

'

,,

l

, , ?, ; ' :'

-

2 p ~~ ;

RO

20

8008 27o []O

LLBeratantha

KVSeyfrit

3/28/74