JUL 10G2 A. Schwneer, Chief, PWR Breach S, L I
j SACIWerit NWIECIPAL tFf!LIff DTrmer (SWD) - BANCBD SECO -
nonzrr 30 5o-312 - muuzza zu Carazaarr Luem We have nyieved the report dated June 6,17T2, dich describes the engineering evaluation ande of worst esse condition of the bulges l
in the containment liner. Se analytical investigation in the area of the =mwi== bulge confirm that the forces, displacements, and strains imposed by accident icodings are within the especity of the liner plate and its anehne system.
B0 plans no further action regarding this natter, but as pointed out in our acknoviedenent letter to the licensee (copy enclosed) you may have questions, in dich case you may wish to contact the licensee directly.
J. B. Henderson, Chief annetor Construction Branch, B0 Enclosures Ltr., Krussi to Mattimon O
)
80032609((
-