Notifies of Intent to Discontinue Preoperational Radiological Monitoring Program Due to Completion of Program Goals.Tables Re General Pathway Radiological Environ Monitoring Program & Sample Station Locations Encl
ML19308D695
Person / Time
Site: Crystal River 
Issue date: 03/03/1975
From: Rodgers J
FLORIDA POWER CORP.
To: Anthony Giambusso
Office of Nuclear Reactor Regulation
References
NUDOCS 8003120829
Download: ML19308D695 (5)


Text

^

NRC DISTRIBUTION FOR PART 50 DOCKET MATERIAL (TEMPORARY FORM) 2458 CONTROL NO:

FILE:

FROM: Florida Power Corporation DATE OF DOC DATE REC'D LTR TWX RPT OTHER St. Petersburg, Fla. 33733 Mr. J.T. Rodners 3-3-75 3-5-75 Y

TO:

ORIG CC OTHER SENT AEC PDR XXX M

A. Giambusso 1 signed SENT LOCAL PDR CLASS UNCLASS PROPINFO INPUT NO CYS REC'D DOCKET NO:

XXX 1

50-302 DESCRIPTION:

ENCLOSURES:

Ler re theit 7-13-74 and 10-21-74....

Information concerning request for extension traas the following.....

of the Const Permit.....and Radiological Monitoring Pro gtap.....

DIST PER ENGLE (1 cy encl rec'd)

PLANT NAME:

Crystal River #3

[,,,~

FOR ACTION /INFORMATION 3_s_75

.in BUTLER (L)

/SCHWENCER (L) ZIEMANN (L)

REG AN (E)

W/ Copies W/2 Copies W/ Copies W/ Copies CLARK (L)

STOLZ (L)

DICKER (E)

LEAR (L)

W/ Copies W/ Copies W/ Copies W/ Copies PAR R (L)

VASSALLO (L)

KNIGHTON (E)

SPELS W/ Copies W/ Copies W/ Copies W/ Copies KNIEL (L)

PURPLE (L)

YOUNGBLOOD (E)

W/ Copies W/ Copies W/ Copies W/ Copies INTERNAL DISTRIBUTION E 9EG FILE)

TECH REVIEW DENTON LIC ASST A/T IND -

6inc eun SCHROEDER GRIMES R. DIGGS (L)

BRAITMAN OGC, ROOM P-506A MACCARY

  1. GAMMILL H. GEARIN (L)

SA LTZM AN l

GOSSICK/ STAFF KNIGHT KASTNER V E. GOULBOURNE (L)

MELTZ l

CASE PAWLICKl BALLARD P. KREUTZER (E) l GIAMBUSSO SHAO SPANGLER J. LEE (L)

PLANS l

BOYD STELLO M. MAIGRET (L)

MCDONALD MOORE (L)

HOUSTON ENVIRO S. REED (E)

CHAPMAN l

DEYOUNG (L)

NOVAK MULLER M. SERVICE (L)

DUBE (Ltr)

SKOVHOLT (L)

ROSS DICKER S. SHEPPARD (L)

E. COUPE GOLLER (L) (Ltr)

IPPOLITO KNIGHTON M. SLATER (E)

PETERSON P. COLLINS TEDESCO YOUNGBLOOD H. SMITH (L)

HARTFIELD (2)

DENISE LONG REGAN S. TEETS (L)

KLECKER

/ REG OPR LAIN AS

/ PROJECT LDR G. WILLI AMS (E)

EISENHUT FILE & REGION (2)

BENAROYA Baj wa V. WILSON (L)

WIGGINTON T.R. WI LSON VOLLMER HAR LESS R. INGRAM (L)

STEELE 2(f v

?

EXTERN AL DISTRIBUTION 74

  1. 1 - LOCAL PDR Crvstal River, Fla.

/1 - TIC (ABERNATHY) (1)(2)(10) - N ATIONAL LABS 1 - PDR SAN /LA/NY

/1 - NSIC (BUCHANAN) 1 - W. PENNINGTON, Rm E-201 GT 1 - BROOKHAVEN NAT LAB 1 - ASLB 1 - CONSU LTANTS 1 - G. ULRIKSON, ORN L 1 - Newton Anderson NEWM AR K/BLUM E/AG BABI AN 1 - AGMED (RUTH GUSSMAN)

- ACRS HOLDING /SENT Rm B2127 GT,

1 - J. D. RUNKLES, Rm E-201 GT 03720 [] p g

fjf

'w.-.

f3r R

'O +=~-

4 0 *[

)QJ

'* C M p m]

s 4) l-oQogy.f 2ae W March 3, 1975 Power e

C O n Po n a t.o m Mr. A. Giambusso Director, Division of I

Reactor Licensing Office of Regulation

,,,1 ; Q Nuclear Regulatory Commission

  • ~

Washington, D. C.

20545 d

RE: Florida Power Corporation Crystal River Nuclear Generating Plant Docket No. 50-302

Dear Mr. Giambusso:

In our previous letters of July 12, 1975 and October 21, 1975, Florida Power Corporation requested an extension of time for completion of Cryst.

River Unit #3 from September 30, 1974 to December 31, 1976.

The Commission responded to our request on February 12, 1975 by extending Florida Pcwer Corporation's Construction Permit No. CPPR-51 to the requested date of December 31, 1976. Due to this additional delay in the completion of Crystal River #3 it is our intent to discontinue our Preoperational Radiological Environmental Monitoring Program, which has been in operation since mid 1970, and begin the development of the Operational Radiological Environmental Monitoring Program. We believe that this change is justifiable as the original intent of the Preoperational Program, which was to establish baseline radiological environmental concentration values, has been met.

A summary of the preoperational surveillance results for 1P" through 1974 which will be used as the baseline concentrations is r,nown in Table 3.2-1 of the Commission's latest Draft of the Environmental Technical Specifications (ETS) for Crystal River Unit #3.

The Operational phase of the Radiological Monitoring Program shall consist of measurements of radioactivity in environmental media as outlined in Table 3.2-2 of the ETS for Crystal River Unit #3.

Our development of the Operational Program will be accomplished during 1975 and the period of 1976 preceeding fuel loading which is currently scheduled for May,1976.

j The sampling stat' ens and their locations identified in Table 1 and Table 2, respectively, will be functional in 1975. These sampling stations will enable us to monitor the environment for any external radiological changes during the transition period and thus insure consistency between the Pre-operational and Operational phases.

The remaining sample sta S ns and analyses of the Operational Radiological Monitoring Program indentified in Table 3.2-2 of the ETS which are not included in Table 1 above, will be added in January of 1976. The remaining time prior to fuel loading in 1976 will be used as a testing period of the total Operational Program

< I' } y General Office 32o1 Thirty-fourtn street soutn. P O Bcx 14042, St Peterscurg. F or'ca 33733 813 - 866-5151

.- 3 y

)

to smooth out any problem areas prior to its implementation at the time of fuel loading.

The above outlined course of action by Florida Power Corporation will be followed as planned unless otherwise directed by the Comission.

In addition, any necessary modifications to the Crystal River Unit #3 Safety Analysis Report to reflect this transition will be made in Amendment No. 45.

Very truly yours

'08 '

J./,T. Rodgersfj Dv As'st. Vice Presi(int JTR/hw 1/1 l

4

~

TABLE 1 GENERAL PATHWAY RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Pcthway Sample Sample Sanpling/ Collection Analysis Significant Type Stations Frequency Routine Radionuclides Air External 004,C07,C18,C14H, Continuous / Quarterly TLD Xe-133,KR-88 Submersion Radiation C40,C41,042,C14M, C43,C46,C14G Air Air C04,007,C18, Continuous / Weekly Gross B and I-131 Inhalation C41 I-131 weekly, y-spectral on

(

monthly composite Precipita-Total C04 Continuous / Monthly H-3,,-Spectral Cs-134,Cs-137,H-3 tion Deposition analysis I-131 River Water Water C15 Quarterly H-3,y-spectral CS-134,CS-137, I-131 analysis Ground Water Water C44 Semi-Annual y-spectial CS-134,Cs-137,I-131 analysis H-3 H-3 Potable Water C07,C10,C18 Quarterly Extendedy-spectral CS-134,Cs-137,I-131 analysis, H-3 H-3 Ingestion Milk C28 Quarterly I-131,Sr-89,90,CS-I-131 Milk 137,Ba-140,K-40

(

Ingestion Food Crops C19 Annual or at harvest y-spectral analysis I-131 Food Crops (Citrus)

Ingestion Food Crops C04 Annual or at harvest y-spectral analysis I-131 Food Crops (Watermelon)

V.

TABLE 2 SAMPLE STATION LOCATIONS Distance from Direction from olant Station plant (miles).

Location Number _

NE 6.9 Sec. 7T17 State Road 17E C04 State Park Old Dam on River ESE 7.5 Crystal River Public C07 Water Plant SE 4.9 Indian Waters Public C10 Water Supply W

1.4 Cl4(a)

Discharge Canal N

5.9 Withlacoochee River C15 Yankeetown Dock Isaac Walton Lodge N

5.8 Yankeetown City Well C18 NE 12.6 NW Corner SR448 C19 SE 22.0 Milkaway Dairy C28 ENE 1.5 On site near N.E.

C40 Boundary at excavated pond and pump station SSW 0.4 On-site Meteorological C41 tower W

1.2 Mid-way out discharge C42 canal on S. side NW 1.6 S.E. corner Holland C43 Ranch E

0.2 On-site well supply to C44 plant softner NE 0.8 N.E. Corner of site boundary C46 Cl4H refers to a station at the head end of the discharge canal; C14M refers to a station midway between the ends of the canal; Cl4G refers (a) to a station at the Gulf of Mexico end of the canal.