ML19308D408

From kanterella
Jump to navigation Jump to search
Discusses Mgt Interview in Insp Rept 50-302/71-03 Re Util Plans for Sample Examination of One Valve Per Pattern. Concerns Include Individual Casting Problems & Degree of Confidence in Valves within Primary Pressure Boundary
ML19308D408
Person / Time
Site: Crystal River 
Issue date: 09/07/1971
From: Henderson J, Whitesell D
US ATOMIC ENERGY COMMISSION (AEC)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19308D409 List:
References
NUDOCS 8002280718
Download: ML19308D408 (1)


Text

.

./s.

m RE: FI4RIDA POWER CORPORATION (CRYSTAL RIVER 3)

.DCCEET 50-302 VERIFICATION OF YALVE WALL

'3tICENIB8 CO Inspection Report 50-302/71-03," management F. J. Long Interview," Paragraph D, ntates that FFC plans Region II I

a sample emmination of one valve for each pattern.. This approach does not eliminate the follaeing concerns:

1.

Eheh valve is indivia=11y cast, and subjoet to individual casting problems.

Measurements made in the field indicated that in several instance, the ID of the valve was not conrentrie with the CD of the valve, and the degree of essentrisity was'not sufficiently constant to promote.,

confidence in a ---aling program. Some of the valves measured, although reasonably consentrie, had thin walls in various areas, the cause for which was not readily apparent.

2.

The degree of confidence required for the safety and reliability of all the valves within the primary pressure boundary appears to dictate that each valve vill have in be measured and documented that the wall thiehsee meets the design requirusents. It might be possible for the licenses to transfer this responsibility to his valve vendor for all those valves not yet delivered.

ce:

A. Ciambusso B. N. Engelken 1

J. Davis, CorII

]D E

U vv g 7 n

v 3

8 o os 28o 7/p OmCE >

'hltese s

sunnAuc,

ender,p J 4--h,4dersen--

Y-7/-71 9/7/71 DATE >

was AEC-SIS (Rev.9-53) AECM 0240 t'. 3. 00VERNMENT PRUETD00 OFFICE : 2970 3 405 348 t-ww