_

Y%

V Lic 3/31/80 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of

)

)

METROPOLITAN EDISON COMPANY

)

Docket No. 50-289

)

(Restart)

(Three Mile Island Nuclear

)

Station, Unit No. 1)

)

LICENSEE'S RESPONSE TO THE FOURTH SET OF INTERROGATORIES FROM THE AAMODT FAMILY (DATED FEBRUARY 22, 1980)

INTERROGATORY NO. 1 What conversations and comments made by personnel on duty in the control room are recorded?

(a)

If available, provide for TMI-2 during the hours of 4 a.m. until 9 a.m.

RESPONSE

There is no capability to record conversations in the con-trol room.

(a)

Since recording capability does not exist, there are no recorded conversations during the hours of 4 a.m. until 9 a.m. on March 28, 1979.

INTERROGATORY NO. 2 What data will be, or is planned to be, monitored by NRC staff at an NRC control center according to your Emergency Plan?

RESPONSE

The NRC Operations Center in Bethesda, Maryland, and the Region I Office in King of Prussia, Pennsylvania are tied to Licensee by direct telephone communication devices.

Through

.8 Of 4 2 4 ooo1r

. the use of these communication systems, the NRC is informed of plant emergencies, plant status, and radiological releases.

INTERROGATORY NO. 3 What will be the mechanism for data transmission?

RESPONSE

The mechanism for data transmission is the communication system described in Licensee's response to Interrogatory No.

2.

INTERROGATORY NO. 4 What objection, if any, would Licensee have to providing this data simultaneously to local county commissioners?

RESPONSE

Consistent with the Pennsylvania State Disaster Operations Plan (Annex E) and NRC requirements, Licensee provides technical t

data directly to the Pennsylvania Bureau of Radiation Protection

(" B RP " ) and the NRC.

BRP advises PEMA on site conditions and PEMA transmits this information to the appropriate county organi-zations.

In this manner, Licensee provides information to the local county commissioners through their county emergency manage-ment agencies.

Licens'ee believes it is preferable to provide data in the first instance to BRP personnel, who have suffi~ient technical training to comprehend properly the significance of the data.

INTERROGATORY NO. S What was Licensee's role in restricting national TV news pro-gramming in the Earrisburg area during TMI-2 accident?

, RESPONSE Licensee did not restrict national TV programming in the Harrisburg area during the TMI-2 accident; Licensee exercises no control over the national TV news.

INTERROGATORY NO.

6.

What studies have been made to assure telephone circuit avail-ability during an emergency?

RESPONSE

The TMI Unit 1 Emergency Plan describes the primary and backup communication systems that will be used during emergency conditions (Emergency Plan S 4.7.5).

Many of the telephone cir-cuits described therein are dedicated lines always available to the plant staff.

In addition, the communication system is not re-stricted to the use of telephones.

INTERROGATORY NO. 7 Describe in detail the expected actions to be taken by a shift supervisor in the course of an event which leads to declaration of Gal a site emergency, 1

(bl a general emergency.

RESPONSE

During Site and General Emergencies, and in the course of events that led to their declaration, the shift supervisor is required to take the following actions:

(1)

Classify the event; (21 Ensure safe operation of the plant by implementa-tion of emergency procedures;

. ~

. (3)

Ensure that immediate notification requirements are met; (4)

Dispatch Radiological Monitoring Teams; and (5)

Assess plant conditions and respond.

INTERROGATORY NO. 8 Provide model scenarios for 7.

RESPONSE

Model scenarios are contained in NUREG-0610 under " Example PWR Sequences".

In addition, Table 6 of the TMI Unit 1 Emergency Plan contains the FSAR analyzed accidents and the emergency clas-sification in which they will most likely fall.

Respectfully subm,itted, SHAW, PITTMAN, POTTS & TROWBRIDGE M

'b./

By:

f,fsju V6rgfF.'TfMwbridge

/

Robert E.

Zahler Dated:

March 31, 1980 t

I

S haw, PITTM AN. PoTTs & TROWB RIDG E 1800 M S TR E ET, N. W.

WAS HINGTON, D. C. 20036 KAMSAv O. potTS STE pM EN e. MuTTLE R (202) 331 AICO RTEUART L. PITTM AN WINTHRop N. BROWN

@ EORGE F. TROW 8 MIDGE JAM E S 3. M AM LIN FTEPH EN D. POTTS ROBERT E ZAMLER TELEcoplER GE R ALD CHARNOFF RICHARO E GALEN PHILLip D gOSTWICM ROB ERT B. ROSSINS (202)296 0694 & 296 1760 R. TIMOTHY MAN LON STEVEN M.LUCAS G EORG E M. ROG ERS. JR.

M Aff AS F. TRAVIESO OIAZ JOHN 5 RMINELANDER VICTORIA J. PERMINS TELEX 05uCE W. CHURCHILL JOMN M. O'N EIL L. J R.

LESLIE A. NICMOLSON. J R.

JAf A. EPSTIEN OO*IOO O ##

M A RTIN O. KR ALL RAND L. ALLEN CA S LE " S M AW LAW "

KICH ARO J. M ENDALL TIM OTH Y 8. Me SRIDE JAY C. SILGERG CLISABETH M. PENDLETON CAR G AR A M. RO S SOTTI LUCY G. ELIASOF EDWARD 8' CROSLAND G EO RG E V. ALLEN. J R.

PAU L A. M APLAN WM. SRADFORO REYNOLDS MARRY M. GLASSPICG EL COUNSEL F:' EO A. LITTLE THOM AS M. McCORMICK FRZO ORASNER SUSAN O.FALMSON N ATH ANIEL p. BRE CO. JR.

WILLIAM p. 5 ARR AARM AUG EN G LIC M JOHN L.CARR.JR.

EEN CST L. BLAKE. J R.

mMILip J.MARVEY CARLETON 5. JONES ROS ERT M. GORDON THOM AS A. BAxTER J EANN E A. CALDERON JAM ES M. SURG ER BAR S AR A J. MORG EN

  • SH ELDON J. WEISEL SONNIE S. GOTTLIES JOHN A. McCULLOUGH ALFR ED M. POSTELL J. RATRIC K MsCM ET SETH M, MOOGASI AN sAMES THOMAS LEN MART SH EILA E.MeCAFFERTY STEVEN L. M ELTZ E R DELISSA A. RIDGWAY DEAN O. AU LICM M EN N CTM J.MAUTMAN JOHN ENGEL CAvlO LAWRENCE MILLER March 31, 1980

~or AoM.rno

..I o. c.

Ms. Marjorie M. Aamodt R.D.

5 Coatesville, Pennsylvania 19320 Re:

Three Mile Island Unit 1

. Docket No. 50-289 (Restart)

Dear Ms. Aamodt:

I enclose Licensee's responses to your fourth set of interrogatories, dated February 22, 1980.

Copies of signed affidavits for these responses are not enclosed, but will be forwarded soon.

Sin rely yo s,

i eor F. Tro bridge l

l Enclosure cc:

Service List

.