05000334/LER-1978-054-03, /03L-0 on 781005:During Surveillance Test on Containment High Pressure Bistable,The Setpoint Was 2.3 Lbs Instead of 2.0.Caused by Faulty Elco Connector on Loop Signal Comparator.Comparator Was Replaced

From kanterella
(Redirected from ML19294A445)
Jump to navigation Jump to search
/03L-0 on 781005:During Surveillance Test on Containment High Pressure Bistable,The Setpoint Was 2.3 Lbs Instead of 2.0.Caused by Faulty Elco Connector on Loop Signal Comparator.Comparator Was Replaced
ML19294A445
Person / Time
Site: Beaver Valley
Issue date: 11/04/1978
From: Werling J
DUQUESNE LIGHT CO.
To:
Shared Package
ML19294A444 List:
References
LER-78-054-03L, LER-78-54-3L, NUDOCS 7811130220
Download: ML19294A445 (1)


LER-1978-054, /03L-0 on 781005:During Surveillance Test on Containment High Pressure Bistable,The Setpoint Was 2.3 Lbs Instead of 2.0.Caused by Faulty Elco Connector on Loop Signal Comparator.Comparator Was Replaced
Event date:
Report date:
3341978054R03 - NRC Website

text

. _. _

U. S. NUCLEAR REGULATORY COMMISSION NRC (dfW 366 wm LICENSEE EVENT REPORT CONTROL 8 LOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIREO INFORMATION)

I C

@ l P l A l B l V l S l 1 l@l 0 l0 l-l 0 l0 l 0 l 0 l 0 l-l0 l 0 l@[4 l1 l1 l1 l1 ]@]

l l@

i 8 9 LICENSEE CODE le IS LICENSE NUMasER 25 26 LICENSE TYPE JO SF CAT Se CON'T [y*,"c' l L @l 015 l 0 l 0 l 0 l 3 l 3 l 4 @l I l 0 i 0 ] S l 7l 8 @l Il II Ol 4l 7l 8l@

loI>l 7

8 60 61 DOCK ET NuveER 66 69 EVENT DATE 74 75 REPORT C ATE 80 EVENT DESCRIPTION ANO PROS ABLE CONSEQUENCES h lol21 During performance of a surveillance test on containment high pressure bistable, l

l the setpoint was determined to be 2.3 pounds rather than 2.0 pounds.

The o 3 l o l 4 l l containment was at atmospheric pressure when the test was performed.

The health I

l o I s l 1 and safety of the public was not jeopardized since the remaining instrument loops l

I lo [s l were operable.

I lo l7l 1 l

O 8

l 80 O E OE SusCO E COMPONENT CODE SUB dE SU E

8 I Il Bjh [E]@ LBjh l Il Nl Sl Tl Rl Ulh dh d h 7

8 9

10 II 12 13 18 19 20 SE QUE NTI AL OCCURRENCE REPORT REVISION LERiRO EVENT YS AR REPORT NO.

CODE TYPE N O.

@,RE g l21718l l-l l O l 51 41 d

10 13 l M

l-l [Q.)

22 23 24 26 27 28 29 30 31 32 u

7 N

O ONP NT T

MOURS S 8 i FC S.

SuPPLIE MANUF C RER L^_]@l l@

L2J@

l 2 l@

Iofofolof Is_J@

LLl@

Ls_l@

Ix o I o I al@*

33 34 35 36 31 40 41 42 4J 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h i o l The incident resulted from a faulty "ELC0" connector on the loop signal comparator. I I

lThe connector was replaced and the loop was successfully tested.

i i I

i 2 l I

I i I 31 I i

i 4 I

1 a 9 ST

% POWER OTHER STATUS dis RY DISCOVERY DESCRIPTION [Gj@ l0l0l0l@l N/A l

W @l Surveillance test l

i s A TiVITY CO TENT RELEASEo Or RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE [Z_] h [2]@l N/A l

l N/A l

i 6 PER$oNNEt ExPoSSES l 0 l O l 0 lhWh[cESCRiPTiON h NuMsER TvPE l

N/A i 7

,ERSON~E't,~d ES DESCR., TION @

l NUMBER I R 1010l0l@l N/A

. 9 i,

LOSS OF OR D AM AGE TO F ACILITY l

TYPE

DESCRIPTION

LZ.j@l N/A i 9 SO F

8 9 to NRC USE ONLY

'"'" 7CR,,1,0~ @

7 81113 Op0 Q 55uf hl N/A l

[l l l-l l l l l 1 I I 15 oE 68 69 80*3 i

4 9 to 412-643-1258 I

J. A. Werling PHONE:

NAME OF PREPARER