N UNITED STATES r

.[

. ?*

NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555

%,.....f METROPOLITAN EDISON COMPANY JER2EY CENTRAL POWER AND LIGHT COMPANY PENNSYLVANIA ELECTRIC COMPANY DOCKET NO. 50-289 THREE MILE ISLAND WUCLEAR STATION, UNIT NO 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 22 License No. DPR-50 1.

The Nuciear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Metropolitan Edison Company, Jersey Central Power and Light Company, and Pennsylvania Electric Company (the licensees) dated June 3,1976, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in confomity with the application, the pro'risions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations;

~ D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment.

7 9 M 110 / 75

.158 043 gasseaudiij,6

.2-This license amendment is effective as of the date of its issuance.

3.

FOR THE NUCLEAR REGULATORY C0!EISSION

/

4 Robert W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors

Attachment:

Changes to the Technical Specifications Date of Issuance:

November 8, 1976 150 044

ATTACHMENT TO LICENSE AMENDMENT N0. 22 FACILITY OPERATING LICENSE NO. DPR-50 DOCKET NO. 50-289 Revise Appendix B as follows:

Remove pages 64, 65, and 66 and insert attached pages 64, 65, and 66.

Changes on the revised pages are shown by marginal lines.

159 045

- 6h -

5.6.2 Hon-Routine Perorts 5.6.2.1 Radicaetive nischarge The non-routine reporting require =ents for radioactive discharges are specified in Section 2.3 of the Environmental Technical Specifications.

5.6.2.2 Radiolerical Environ = ental Menitorine a.

Anemalous Measure =ents (1) If a measured level of radioactivity in any environmental medium, other than those associated with gaseous radiciodine releases, exceeds ten times the mean of the precrerational/

operational control station data, or lacking this value, ten times the-applicable control station data, a written notification vill be submitted within ten days, advising the NRC of this condition.1 "his notification should include an evaluation of any release conditione, environ-mental factors, or other aspects naessary to explain the ano=alous result.

(2) If a measured level of radioactivity in any environmental medium, other than those associated with gaseous radio-iodine releases, exceeds the Investigation Ievel, (section (b) below), the following action vill be taken:

(a) Confirm data bv:

(1) Recount same sample (if possible)

(2) Count second half (duplicate) of sample (if possible)

(3) If (1) and (2) is greater than Investigation Level (or if (1) 4 (2) are not feasible),'then take a new sample (as representative as possible of the old sa=ple) as soon as practicable.

lIn case of a tentatively anomalous value for radiostrontium, a ecnfirnatory reanalycis of the original, a duplicate or a new sample =ay be desirable.

In this instance the results of the confir atory analysis shall be co=pleted at the earliest time consistent with the analysis, and if the high value is real, the report to the IEC shall be submitted within ten days following this analysis report.

15 8 046 Amendment No. 22

- (b) Investigatien Level Criteria for deter =ining when a control station value has been exceeded:

(1) The control station value has not been exceeded if there is a oo.0% probability of its belonging to the background or control station data population distribution. This means that 0.1% of the ttne this value vill te said to be different from the background, when in fact, it is not different.

(2) The limit for this criteria is express-ed as:

(10 of X x 3.1)+X, where X is the mean and a = one standard deviation.

If the data point is greater than background

+ 3.1c of background, then the Investigation level has been reached.

b.

Milk Pathvay Measurements If individual milk samples show I-131 concentrations of 10 picicuriesper liter or greater, a plan vill be submitted within one week advising the NRC of the proposed action to ensure the plant related annual doses vill be within the design objective of 15 mrem /yr to the thyroid of any individual.

c.

Ano. alous Measure =ents Urattributable to the TA caea.a ein,t If levels of radiation can be definitely shown to result from scurces other than the licensed plant (e.g. from testing of nuclear devices) by similar concentrations found in " background samples that could not be affected by emission from the licensed plant" the reporting actions in items a and b need not be taken. Justification for assigning high levels of radioactivity to sources other than the plant shall be provided in the annual report.

5.6.2.3 Nonradiolocical

~

In the event a Limiting Condition for Operation is exceeded, a report vill be =ade within 2h hours by telephone and telegraph to the Office of Inspection and Enforcement - Region 1 followed by a written report within two weeks (ce to the Director of Nuclear Reactor Regulation).

The written report and, to the extent possible, the preliminary telephone and telegraph report, vill:

1) Describe, analyze and evaluate the occurrence including extent and =agnitude of the impact;
2) Describe the cause of the occurrence; and
3) Indicate the corrective action taken (including any significant changes made in procedures) to preclude repetition e t the s

occurrence and to prevent similar occurrences involving similar components or systems.

Amendment 1/,22 15I.)047

5.6.2.h

. Chances

1) When a change to the plant design, to the plant operatien or to the procedures described in Section 5.5 is planned which would have a significant adverse effect on the envirennent or which involves an envirennental matter or question not previously reviewed and evaluated by the NRC, a report on the change vill be made to the NRC prior to imple=entation.

The, report will include a description and evaluation of the change including a supporting benefit-cost analysis.

2) Changes or additions to permits and certificates required by Federal, State, local and regional authorities for the protection of the environment vill be repcrted. When the required changes are submitted to the concerned agency for approval, they vill also be submitted to USNRC for infor=ation.

The submittal vill include an evaluatien of the environmental impact of the change.

3) Requests for changes in Environmental Technical Specifications vill be submitted to the USNPC for prior review and authorizatien.

The request will include an evaluation of the imp,act of the change, including a supporting benefit-cost analysis.

5.6.2.5 other If harmful effects or evidence of irreversible damage are detected by the monitoring progra=s, the licensee shall provide on analysis of the problem and shall develop a course of action to be taken to alleviate the problems. If the ecolcgy of the river significantly changes at a future date as, for example, by major changes in water chemistry or reintroduction of shad, the licensee shall provide an analysis of expected impacts and a course of action to minimize the impacts.

a 57 Records Retentien 5.7.1 Records and logs relative to the following areas vill be retained for the life of the plant.

a.

Records and drawing changes reflecting plant design changes made to systems and equipment as described in Section 5.6.2.h.

b.

Records of environmental surveillance data.

c.

Records to de=enstrate ecmpliance with the Limiting Cenditiens for Operation in Section 2.

57.2 All other records and legs relating to the Environmental Technical Specifications shall be. retained for 5 years.

151lIE 048 Amendment No. 22

,